Optimal Sensor Placement for Leak Location in Water Distribution Networks using Evolutionary Algorithms

In this paper, a sensor placement approach to improve the leak location in waterdistribution networks is proposed when the leak signature space (LSS) method is used.The sensor placement problem is formulated as an integer optimization problem where thecriterion to be minimized is the number of overl...

Full description

Bibliographic Details
Main Authors: Myrna V. Casillas, Luis E. Garza-Castañón, Vicenç Puig
Format: Article
Language:English
Published: MDPI AG 2015-11-01
Series:Water
Subjects:
Online Access:http://www.mdpi.com/2073-4441/7/11/6496
Description
Summary:In this paper, a sensor placement approach to improve the leak location in waterdistribution networks is proposed when the leak signature space (LSS) method is used.The sensor placement problem is formulated as an integer optimization problem where thecriterion to be minimized is the number of overlapping signature domains computed fromthe original LSS representation. First, a semi-exhaustive search approach based on a lazyevaluation mechanism ensures optimal placement in the case of low complexity scenarios.For more complex cases, a stochastic optimization process is proposed, based on eitherthe genetic algorithms (GAs) or particle swarm optimization (PSO). Experiments on twodifferent networks are used to evaluate the performance of the resolution methods, as well asthe efficiency achieved in the leak location when using the sensor placement results.
ISSN:2073-4441