An Efficient Teager Energy Operator-Based Automated QRS Complex Detection

Database. The efficiency and robustness of the proposed method has been tested on Fantasia Database (FTD), MIT-BIH Arrhythmia Database (MIT-AD), and MIT-BIH Normal Sinus Rhythm Database (MIT-NSD). Aim. Because of the importance of QRS complex in the diagnosis of cardiovascular diseases, improvement...

Full description

Bibliographic Details
Main Authors: Hamed Beyramienanlou, Nasser Lotfivand
Format: Article
Language:English
Published: Hindawi Limited 2018-01-01
Series:Journal of Healthcare Engineering
Online Access:http://dx.doi.org/10.1155/2018/8360475
id doaj-fa705c007b7c4060adeaff997fe57d9c
record_format Article
spelling doaj-fa705c007b7c4060adeaff997fe57d9c2020-11-25T02:27:50ZengHindawi LimitedJournal of Healthcare Engineering2040-22952040-23092018-01-01201810.1155/2018/83604758360475An Efficient Teager Energy Operator-Based Automated QRS Complex DetectionHamed Beyramienanlou0Nasser Lotfivand1Department of Electronic Engineering, Tabriz Branch, Islamic Azad University, Tabriz, IranDepartment of Electronic Engineering, Tabriz Branch, Islamic Azad University, Tabriz, IranDatabase. The efficiency and robustness of the proposed method has been tested on Fantasia Database (FTD), MIT-BIH Arrhythmia Database (MIT-AD), and MIT-BIH Normal Sinus Rhythm Database (MIT-NSD). Aim. Because of the importance of QRS complex in the diagnosis of cardiovascular diseases, improvement in accuracy of its measurement has been set as a target. The present study provides an algorithm for automatic detection of QRS complex on the ECG signal, with the benefit of energy and reduced impact of noise on the ECG signal. Method. The method is basically based on the Teager energy operator (TEO), which facilitates the detection of the baseline threshold and extracts QRS complex from the ECG signal. Results. The testing of the undertaken method on the Fanatasia Database showed the following results: sensitivity (Se) = 99.971%, positive prediction (P+) = 99.973%, detection error rate (DER) = 0.056%, and accuracy (Acc) = 99.944%. On MIT-AD involvement, Se = 99.74%, P+ = 99.97%, DER = 0.291%, and Acc = 99.71%. On MIT-NSD involvement, Se = 99.878%, P+ = 99.989%, DER = 0.134%, and Acc = 99.867%. Conclusion. Despite the closeness of the recorded peaks which inflicts a constraint in detection of the two consecutive QRS complexes, the proposed method, by applying 4 simple and quick steps, has effectively and reliably detected the QRS complexes which make it suitable for practical purposes and applications.http://dx.doi.org/10.1155/2018/8360475
collection DOAJ
language English
format Article
sources DOAJ
author Hamed Beyramienanlou
Nasser Lotfivand
spellingShingle Hamed Beyramienanlou
Nasser Lotfivand
An Efficient Teager Energy Operator-Based Automated QRS Complex Detection
Journal of Healthcare Engineering
author_facet Hamed Beyramienanlou
Nasser Lotfivand
author_sort Hamed Beyramienanlou
title An Efficient Teager Energy Operator-Based Automated QRS Complex Detection
title_short An Efficient Teager Energy Operator-Based Automated QRS Complex Detection
title_full An Efficient Teager Energy Operator-Based Automated QRS Complex Detection
title_fullStr An Efficient Teager Energy Operator-Based Automated QRS Complex Detection
title_full_unstemmed An Efficient Teager Energy Operator-Based Automated QRS Complex Detection
title_sort efficient teager energy operator-based automated qrs complex detection
publisher Hindawi Limited
series Journal of Healthcare Engineering
issn 2040-2295
2040-2309
publishDate 2018-01-01
description Database. The efficiency and robustness of the proposed method has been tested on Fantasia Database (FTD), MIT-BIH Arrhythmia Database (MIT-AD), and MIT-BIH Normal Sinus Rhythm Database (MIT-NSD). Aim. Because of the importance of QRS complex in the diagnosis of cardiovascular diseases, improvement in accuracy of its measurement has been set as a target. The present study provides an algorithm for automatic detection of QRS complex on the ECG signal, with the benefit of energy and reduced impact of noise on the ECG signal. Method. The method is basically based on the Teager energy operator (TEO), which facilitates the detection of the baseline threshold and extracts QRS complex from the ECG signal. Results. The testing of the undertaken method on the Fanatasia Database showed the following results: sensitivity (Se) = 99.971%, positive prediction (P+) = 99.973%, detection error rate (DER) = 0.056%, and accuracy (Acc) = 99.944%. On MIT-AD involvement, Se = 99.74%, P+ = 99.97%, DER = 0.291%, and Acc = 99.71%. On MIT-NSD involvement, Se = 99.878%, P+ = 99.989%, DER = 0.134%, and Acc = 99.867%. Conclusion. Despite the closeness of the recorded peaks which inflicts a constraint in detection of the two consecutive QRS complexes, the proposed method, by applying 4 simple and quick steps, has effectively and reliably detected the QRS complexes which make it suitable for practical purposes and applications.
url http://dx.doi.org/10.1155/2018/8360475
work_keys_str_mv AT hamedbeyramienanlou anefficientteagerenergyoperatorbasedautomatedqrscomplexdetection
AT nasserlotfivand anefficientteagerenergyoperatorbasedautomatedqrscomplexdetection
AT hamedbeyramienanlou efficientteagerenergyoperatorbasedautomatedqrscomplexdetection
AT nasserlotfivand efficientteagerenergyoperatorbasedautomatedqrscomplexdetection
_version_ 1724840567049814016