Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast Augmentation
Background:. Capsular contracture is 1 of the most common complications after breast implant surgery and is a major indication for reoperation. Capsular contracture is believed to be a multifactorial process that is affected by implant texture, incision type, and ultimately pocket contamination. Thi...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer
2018-06-01
|
Series: | Plastic and Reconstructive Surgery, Global Open |
Online Access: | http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000001834 |
id |
doaj-fa676d0daa534d978772a5afb6858018 |
---|---|
record_format |
Article |
spelling |
doaj-fa676d0daa534d978772a5afb68580182020-11-24T20:57:42ZengWolters KluwerPlastic and Reconstructive Surgery, Global Open2169-75742018-06-0166e183410.1097/GOX.0000000000001834201806000-00006Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast AugmentationAshley N. Newman, BS0Steven P. Davison, MD, DDS, FACS1From the Georgetown University School of Medicine, Georgetown University, Washington, D.C.From the Georgetown University School of Medicine, Georgetown University, Washington, D.C.Background:. Capsular contracture is 1 of the most common complications after breast implant surgery and is a major indication for reoperation. Capsular contracture is believed to be a multifactorial process that is affected by implant texture, incision type, and ultimately pocket contamination. This contamination causes a biofilm that leads to capsular contracture. The intraoperative use of a Keller funnel is a mechanical way to decrease the implant’s contact with the skin and ducts, reducing bacterial contamination that can cause these biofilms. For this reason, periareolar breast augmentation has been less popular among surgeons. The purpose of this study was to examine if there was a significant difference between the rates of capsular contracture in patients having periareolar breast augmentations with the use of a Keller funnel for insertion and those having periareolar breast augmentations without Funnel use. Methods:. This level 3 retrospective study followed 2 groups of patients, the first having periareolar breast augmentations without the use of a funnel for insertion (group A; patients n = 15; implants n = 30) and the second having periareolar breast augmentations with the use of a funnel for insertion (group B; patients n = 151; implants n = 300). Results:. The rate of capsular contracture in group A was found to be 10% compared with a rate of capsular contracture of 1.3% for patients in group B, an 87% reduction (P = 0.0019). Conclusions:. According to the results found in this study, the rate of capsular contracture in patients having periareolar breast augmentations after insertion with a Keller funnel was statistically significantly lower than the rate in patients having implants inserted without the assistance of a funnel, making the device useful in reducing the occurrence of postoperative capsular contracture.http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000001834 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ashley N. Newman, BS Steven P. Davison, MD, DDS, FACS |
spellingShingle |
Ashley N. Newman, BS Steven P. Davison, MD, DDS, FACS Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast Augmentation Plastic and Reconstructive Surgery, Global Open |
author_facet |
Ashley N. Newman, BS Steven P. Davison, MD, DDS, FACS |
author_sort |
Ashley N. Newman, BS |
title |
Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast Augmentation |
title_short |
Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast Augmentation |
title_full |
Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast Augmentation |
title_fullStr |
Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast Augmentation |
title_full_unstemmed |
Effect of Keller Funnel on the Rate of Capsular Contracture in Periareolar Breast Augmentation |
title_sort |
effect of keller funnel on the rate of capsular contracture in periareolar breast augmentation |
publisher |
Wolters Kluwer |
series |
Plastic and Reconstructive Surgery, Global Open |
issn |
2169-7574 |
publishDate |
2018-06-01 |
description |
Background:. Capsular contracture is 1 of the most common complications after breast implant surgery and is a major indication for reoperation. Capsular contracture is believed to be a multifactorial process that is affected by implant texture, incision type, and ultimately pocket contamination. This contamination causes a biofilm that leads to capsular contracture. The intraoperative use of a Keller funnel is a mechanical way to decrease the implant’s contact with the skin and ducts, reducing bacterial contamination that can cause these biofilms. For this reason, periareolar breast augmentation has been less popular among surgeons. The purpose of this study was to examine if there was a significant difference between the rates of capsular contracture in patients having periareolar breast augmentations with the use of a Keller funnel for insertion and those having periareolar breast augmentations without Funnel use.
Methods:. This level 3 retrospective study followed 2 groups of patients, the first having periareolar breast augmentations without the use of a funnel for insertion (group A; patients n = 15; implants n = 30) and the second having periareolar breast augmentations with the use of a funnel for insertion (group B; patients n = 151; implants n = 300).
Results:. The rate of capsular contracture in group A was found to be 10% compared with a rate of capsular contracture of 1.3% for patients in group B, an 87% reduction (P = 0.0019).
Conclusions:. According to the results found in this study, the rate of capsular contracture in patients having periareolar breast augmentations after insertion with a Keller funnel was statistically significantly lower than the rate in patients having implants inserted without the assistance of a funnel, making the device useful in reducing the occurrence of postoperative capsular contracture. |