Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation

Natural ventilation is an effective energy-saving strategy conducive to promoting sustainable agricultural production. A comprehensive numerical simulation is performed to predict the airflow pattern and thermal behavior in different arched greenhouses. The defined arc chord angle and position angle...

Full description

Bibliographic Details
Main Authors: He Li, Yiming Li, Xiang Yue, Xingan Liu, Subo Tian, Tianlai Li, Djamel Eddine Ameziani
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2020-01-01
Series:PLoS ONE
Online Access:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7523980/?tool=EBI
id doaj-fa5e3cebf95f458ea4ff1cd2931b8940
record_format Article
spelling doaj-fa5e3cebf95f458ea4ff1cd2931b89402020-11-25T03:54:16ZengPublic Library of Science (PLoS)PLoS ONE1932-62032020-01-01159Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulationHe LiYiming LiXiang YueXingan LiuSubo TianTianlai LiDjamel Eddine AmezianiNatural ventilation is an effective energy-saving strategy conducive to promoting sustainable agricultural production. A comprehensive numerical simulation is performed to predict the airflow pattern and thermal behavior in different arched greenhouses. The defined arc chord angle and position angle are employed to examine the natural ventilation process and corresponding roof vent scenarios. The numerical simulation is compared with the experimental data and good agreements are observed. Various configurations of ventilated structures, wind conditions and ventilation layouts are simulated on a high-resolution polyhedral grid based on a grid sensitivity analysis, which is beneficial to the optimization of greenhouse cooling combined with the water circulation heat collection system. The cooling effect in summer is analyzed by estimating the ventilation flow rate and microclimate inhomogeneity. The results demonstrate that the position angle of 85° of the arched greenhouses is an optimum ventilation direction and its impact on the microclimate is marginally affected by the change of the ventilation structure. The designed ventilation scheme has perfect air exchange capacity and cooling effect because the average air temperature can be reduced by 1.5°C more than the existing greenhouse in 10 minutes of ventilation. Likewise, the results show that the temperature and velocity inhomogeneities are approximately decreased by 33.3% and 11.89%, respectively. The practical value of the research is expected to provide basic quantitative conclusions for evaluating the natural ventilation performance.https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7523980/?tool=EBI
collection DOAJ
language English
format Article
sources DOAJ
author He Li
Yiming Li
Xiang Yue
Xingan Liu
Subo Tian
Tianlai Li
Djamel Eddine Ameziani
spellingShingle He Li
Yiming Li
Xiang Yue
Xingan Liu
Subo Tian
Tianlai Li
Djamel Eddine Ameziani
Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation
PLoS ONE
author_facet He Li
Yiming Li
Xiang Yue
Xingan Liu
Subo Tian
Tianlai Li
Djamel Eddine Ameziani
author_sort He Li
title Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation
title_short Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation
title_full Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation
title_fullStr Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation
title_full_unstemmed Evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using CFD simulation
title_sort evaluation of airflow pattern and thermal behavior of the arched greenhouses with designed roof ventilation scenarios using cfd simulation
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2020-01-01
description Natural ventilation is an effective energy-saving strategy conducive to promoting sustainable agricultural production. A comprehensive numerical simulation is performed to predict the airflow pattern and thermal behavior in different arched greenhouses. The defined arc chord angle and position angle are employed to examine the natural ventilation process and corresponding roof vent scenarios. The numerical simulation is compared with the experimental data and good agreements are observed. Various configurations of ventilated structures, wind conditions and ventilation layouts are simulated on a high-resolution polyhedral grid based on a grid sensitivity analysis, which is beneficial to the optimization of greenhouse cooling combined with the water circulation heat collection system. The cooling effect in summer is analyzed by estimating the ventilation flow rate and microclimate inhomogeneity. The results demonstrate that the position angle of 85° of the arched greenhouses is an optimum ventilation direction and its impact on the microclimate is marginally affected by the change of the ventilation structure. The designed ventilation scheme has perfect air exchange capacity and cooling effect because the average air temperature can be reduced by 1.5°C more than the existing greenhouse in 10 minutes of ventilation. Likewise, the results show that the temperature and velocity inhomogeneities are approximately decreased by 33.3% and 11.89%, respectively. The practical value of the research is expected to provide basic quantitative conclusions for evaluating the natural ventilation performance.
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7523980/?tool=EBI
work_keys_str_mv AT heli evaluationofairflowpatternandthermalbehaviorofthearchedgreenhouseswithdesignedroofventilationscenariosusingcfdsimulation
AT yimingli evaluationofairflowpatternandthermalbehaviorofthearchedgreenhouseswithdesignedroofventilationscenariosusingcfdsimulation
AT xiangyue evaluationofairflowpatternandthermalbehaviorofthearchedgreenhouseswithdesignedroofventilationscenariosusingcfdsimulation
AT xinganliu evaluationofairflowpatternandthermalbehaviorofthearchedgreenhouseswithdesignedroofventilationscenariosusingcfdsimulation
AT subotian evaluationofairflowpatternandthermalbehaviorofthearchedgreenhouseswithdesignedroofventilationscenariosusingcfdsimulation
AT tianlaili evaluationofairflowpatternandthermalbehaviorofthearchedgreenhouseswithdesignedroofventilationscenariosusingcfdsimulation
AT djameleddineameziani evaluationofairflowpatternandthermalbehaviorofthearchedgreenhouseswithdesignedroofventilationscenariosusingcfdsimulation
_version_ 1724474745496272896