Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of Clicker

An archer requires a well-balanced and highly reproducible release of the bowstring to attain high scores in competition. Recurve archers use a mechanical device called the “clicker” to check the draw length. The fall of the clicker that generates an auditory stimulus should evoke a response in the...

Full description

Bibliographic Details
Main Authors: Hayri Ertan, Suha Yagcioglu, Alpaslan Yılmaz, Pekcan Ungan, Feza Korkusuz
Format: Article
Language:English
Published: Montenegrin Sports Academy 2021-03-01
Series:Montenegrin Journal of Sports Science and Medicine
Subjects:
Online Access:https://www.mjssm.me/?sekcija=article&artid=211
id doaj-f9cc8694ffd24a5eae1d97922e8a3ced
record_format Article
spelling doaj-f9cc8694ffd24a5eae1d97922e8a3ced2021-06-02T21:11:02ZengMontenegrin Sports AcademyMontenegrin Journal of Sports Science and Medicine1800-87551800-87632021-03-01101374410.26773/mjssm.210306Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of ClickerHayri Ertan0Suha Yagcioglu1Alpaslan Yılmaz2Pekcan Ungan3Feza Korkusuz4Eskisehir Technical University, Faculty of Sport Sciences, Department of Coaching Education, Eskisehir, TurkeyHacettepe University, Medical School, Biophysics Department, Ankara, TurkeyErciyes University, Faculty of Sport Sciences, Department of Coaching Education, Kayseri, TurkeyKoc University, Medical School, Istanbul, TurkeyHacettepe University, Medical School, Department of Sports Medicine, Ankara, TurkeyAn archer requires a well-balanced and highly reproducible release of the bowstring to attain high scores in competition. Recurve archers use a mechanical device called the “clicker” to check the draw length. The fall of the clicker that generates an auditory stimulus should evoke a response in the brain. The purpose of this study is to evaluate the event-related potentials during archery shooting as a response to the fall of the clicker. Fifteen high-level archers participated. An electro cap was placed on the archers’ scalps, and continuous EEG activity was recorded (digitized at 1000 Hz) and stored for off-line analysis. The EEG data were epoched beginning 200 ms before and lasting 800 ms after stimulus marker signals. An operational definition has been developed for classifying hits corresponding to hit and/or miss areas. The hit area enlarged gradually starting from the centre of the target (yellow: 10) to blue (6 score) by creating ten hit area indexes. It is found that the snap of the clicker during archery shooting evokes N1–P2 components of long-latency evoked brain potentials. N1 amplitudes are significantly higher in hit area than that of miss areas for the 2nd and 4th indexes with 95% confidence intervals and 90% confidence intervals for the 1st and 3rd indexes with 90% confidence intervals. We conclude that the fall of the clicker in archery shooting elicits an N1 response with higher amplitude. Although evoked potential amplitudes were higher in successful shots, their latencies were not significantly different from the unsuccessful ones.https://www.mjssm.me/?sekcija=article&artid=211archeryevoked brain potentialsauditory evoked brain potentialsn1-p2 componentarchery performance
collection DOAJ
language English
format Article
sources DOAJ
author Hayri Ertan
Suha Yagcioglu
Alpaslan Yılmaz
Pekcan Ungan
Feza Korkusuz
spellingShingle Hayri Ertan
Suha Yagcioglu
Alpaslan Yılmaz
Pekcan Ungan
Feza Korkusuz
Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of Clicker
Montenegrin Journal of Sports Science and Medicine
archery
evoked brain potentials
auditory evoked brain potentials
n1-p2 component
archery performance
author_facet Hayri Ertan
Suha Yagcioglu
Alpaslan Yılmaz
Pekcan Ungan
Feza Korkusuz
author_sort Hayri Ertan
title Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of Clicker
title_short Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of Clicker
title_full Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of Clicker
title_fullStr Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of Clicker
title_full_unstemmed Accuracy in Archery Shooting is linked to the Amplitude of the ERP N1 to the Snap of Clicker
title_sort accuracy in archery shooting is linked to the amplitude of the erp n1 to the snap of clicker
publisher Montenegrin Sports Academy
series Montenegrin Journal of Sports Science and Medicine
issn 1800-8755
1800-8763
publishDate 2021-03-01
description An archer requires a well-balanced and highly reproducible release of the bowstring to attain high scores in competition. Recurve archers use a mechanical device called the “clicker” to check the draw length. The fall of the clicker that generates an auditory stimulus should evoke a response in the brain. The purpose of this study is to evaluate the event-related potentials during archery shooting as a response to the fall of the clicker. Fifteen high-level archers participated. An electro cap was placed on the archers’ scalps, and continuous EEG activity was recorded (digitized at 1000 Hz) and stored for off-line analysis. The EEG data were epoched beginning 200 ms before and lasting 800 ms after stimulus marker signals. An operational definition has been developed for classifying hits corresponding to hit and/or miss areas. The hit area enlarged gradually starting from the centre of the target (yellow: 10) to blue (6 score) by creating ten hit area indexes. It is found that the snap of the clicker during archery shooting evokes N1–P2 components of long-latency evoked brain potentials. N1 amplitudes are significantly higher in hit area than that of miss areas for the 2nd and 4th indexes with 95% confidence intervals and 90% confidence intervals for the 1st and 3rd indexes with 90% confidence intervals. We conclude that the fall of the clicker in archery shooting elicits an N1 response with higher amplitude. Although evoked potential amplitudes were higher in successful shots, their latencies were not significantly different from the unsuccessful ones.
topic archery
evoked brain potentials
auditory evoked brain potentials
n1-p2 component
archery performance
url https://www.mjssm.me/?sekcija=article&artid=211
work_keys_str_mv AT hayriertan accuracyinarcheryshootingislinkedtotheamplitudeoftheerpn1tothesnapofclicker
AT suhayagcioglu accuracyinarcheryshootingislinkedtotheamplitudeoftheerpn1tothesnapofclicker
AT alpaslanyılmaz accuracyinarcheryshootingislinkedtotheamplitudeoftheerpn1tothesnapofclicker
AT pekcanungan accuracyinarcheryshootingislinkedtotheamplitudeoftheerpn1tothesnapofclicker
AT fezakorkusuz accuracyinarcheryshootingislinkedtotheamplitudeoftheerpn1tothesnapofclicker
_version_ 1721400891238514688