Endoscopic esophagogastric anastomosis with luminal apposition Axios stent (LAS) approach: a new concept for hybrid “Lewis Santy”

Background and study aims Esophagogastric anastomosis (EGA) has a high risk of leakage. Based upon our experience in endoscopic gastrojejunal anastomosis using LAS, the aim of this study was to verify the technical feasibility and the safety of performing an EGA using a hybrid approach (endoscopic a...

Full description

Bibliographic Details
Main Authors: Adrian Culetto, Jean-Michel Gonzalez, Geoffroy Vanbiervliet, Pablo Miranda Garcia, Juan Ignacio Tellechea, Emmanuelle Garnier, Stephane Berdah, Marc Barthet
Format: Article
Language:English
Published: Georg Thieme Verlag KG 2017-05-01
Series:Endoscopy International Open
Online Access:http://www.thieme-connect.de/DOI/DOI?10.1055/s-0043-106577
Description
Summary:Background and study aims Esophagogastric anastomosis (EGA) has a high risk of leakage. Based upon our experience in endoscopic gastrojejunal anastomosis using LAS, the aim of this study was to verify the technical feasibility and the safety of performing an EGA using a hybrid approach (endoscopic and surgical). Materials and methods A pilot prospective study was performed on 8 survival pigs. The procedure was carried out in 2 stages: (i) surgical step consisting of an esogastrectomy by laparotomy with separated suture of the esophagus and stomach; (ii) endoscopic esophagogastric anastomosis using the LAS. The first 2 pigs allowed for the setting of the 2 steps procedure, and 6 were included in the study for assessing the efficacy and safety of the procedure with a 3-week survival course. The primary endpoint was morbidity and mortality. Results All procedures were successfull. The mean operative time was 98 minutes, with a mean endoscopic time of 46 minutes. Three early deaths occurred within the first weeks, unrelated to the LAS anastomosis. At 3 weeks, endoscopic assessment followed by necropsy demonstrated the right position and the endoscopic removability of the stent with good patency of the esophagogastric anastomosis, without leakage of the endoscopic suture. Pathological examination confirmed the patency of the anastomosis with fusion of mucosal and muscle layers. Conclusion Endoscopic esophagogastric anastomosis with LAS is feasible and reproducible, without anastomotic leakage. It could be a new alternative to perform safe anastomoses, as part of a hybrid approach (surgical and endoscopic).
ISSN:2364-3722
2196-9736