Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions
A work on the design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer suitable for use in tropical regions is presented. The system comprises of a refrigerator with its condenser unit retrofitted to serve as the heat recovery mechanism and a drying c...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-09-01
|
Series: | Heliyon |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2405844020316819 |
id |
doaj-f93af4a62df04dee95520ec48750884b |
---|---|
record_format |
Article |
spelling |
doaj-f93af4a62df04dee95520ec48750884b2020-11-25T03:41:16ZengElsevierHeliyon2405-84402020-09-0169e04838Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regionsEbenezer I. Onyeocha0Kevin N. Nwaigwe1Nnamdi V. Ogueke2Emmanuel E. Anyanwu3Department of Mechanical Engineering, Federal University of Technology Owerri, PMB 1526 Owerri NigeriaDepartment of Mechanical Engineering, University of Botswana, Gaborone, Botswana; Corresponding author.Department of Mechanical Engineering, Federal University of Technology Owerri, PMB 1526 Owerri NigeriaDepartment of Mechanical Engineering, Federal University of Technology Owerri, PMB 1526 Owerri NigeriaA work on the design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer suitable for use in tropical regions is presented. The system comprises of a refrigerator with its condenser unit retrofitted to serve as the heat recovery mechanism and a drying chamber. The refrigerator had a vapour compression cycle driven by environmentally friendly R134a working fluid (refrigerant). The dryer component was powered by heat dissipated by the condenser piping from the exit of the compressor (superheat region) to the entrance of the sub-cooled region. The maximum drying temperature attained during pre-loading test was 49 °C while the evaporator provided cooling at a temperature of 5 °C. The specific moisture extraction rate of the dryer varied over 0.19–0.22 kg/kW.hr while 150W of cooling was produced at the evaporator in all cases. The energy utilization ratio obtained was 0.92, indicating that 92% of the waste heat recovered was actually utilized. The system coefficient of performance was estimated to be 10.09 thus indicating that the energy derived from IRWHRD was 10 times the energy it consumed. Application potentials therefore exist for use of this dual purpose system for simultaneous production of refrigeration and heating. Storage of food and drying of fabrics make the IRWHRD an option for use in both agricultural development and entrepreneurship development in laundry business.http://www.sciencedirect.com/science/article/pii/S2405844020316819EnergyMechanical engineeringEnergy conservationEnergy economicsHeat transferMass transfer |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Ebenezer I. Onyeocha Kevin N. Nwaigwe Nnamdi V. Ogueke Emmanuel E. Anyanwu |
spellingShingle |
Ebenezer I. Onyeocha Kevin N. Nwaigwe Nnamdi V. Ogueke Emmanuel E. Anyanwu Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions Heliyon Energy Mechanical engineering Energy conservation Energy economics Heat transfer Mass transfer |
author_facet |
Ebenezer I. Onyeocha Kevin N. Nwaigwe Nnamdi V. Ogueke Emmanuel E. Anyanwu |
author_sort |
Ebenezer I. Onyeocha |
title |
Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions |
title_short |
Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions |
title_full |
Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions |
title_fullStr |
Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions |
title_full_unstemmed |
Design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions |
title_sort |
design and construction of an integrated tetrafluoroethane (r134a) refrigerator-waste heat recovery dryer for fabric drying in tropical regions |
publisher |
Elsevier |
series |
Heliyon |
issn |
2405-8440 |
publishDate |
2020-09-01 |
description |
A work on the design and construction of an integrated tetrafluoroethane (R134a) refrigerator-waste heat recovery dryer suitable for use in tropical regions is presented. The system comprises of a refrigerator with its condenser unit retrofitted to serve as the heat recovery mechanism and a drying chamber. The refrigerator had a vapour compression cycle driven by environmentally friendly R134a working fluid (refrigerant). The dryer component was powered by heat dissipated by the condenser piping from the exit of the compressor (superheat region) to the entrance of the sub-cooled region. The maximum drying temperature attained during pre-loading test was 49 °C while the evaporator provided cooling at a temperature of 5 °C. The specific moisture extraction rate of the dryer varied over 0.19–0.22 kg/kW.hr while 150W of cooling was produced at the evaporator in all cases. The energy utilization ratio obtained was 0.92, indicating that 92% of the waste heat recovered was actually utilized. The system coefficient of performance was estimated to be 10.09 thus indicating that the energy derived from IRWHRD was 10 times the energy it consumed. Application potentials therefore exist for use of this dual purpose system for simultaneous production of refrigeration and heating. Storage of food and drying of fabrics make the IRWHRD an option for use in both agricultural development and entrepreneurship development in laundry business. |
topic |
Energy Mechanical engineering Energy conservation Energy economics Heat transfer Mass transfer |
url |
http://www.sciencedirect.com/science/article/pii/S2405844020316819 |
work_keys_str_mv |
AT ebenezerionyeocha designandconstructionofanintegratedtetrafluoroethaner134arefrigeratorwasteheatrecoverydryerforfabricdryingintropicalregions AT kevinnnwaigwe designandconstructionofanintegratedtetrafluoroethaner134arefrigeratorwasteheatrecoverydryerforfabricdryingintropicalregions AT nnamdivogueke designandconstructionofanintegratedtetrafluoroethaner134arefrigeratorwasteheatrecoverydryerforfabricdryingintropicalregions AT emmanueleanyanwu designandconstructionofanintegratedtetrafluoroethaner134arefrigeratorwasteheatrecoverydryerforfabricdryingintropicalregions |
_version_ |
1724530662132678656 |