Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.

Polarization-resolved second harmonic generation (P-SHG) microscopy has evolved as a promising technique to reveal subresolution information about the structure and orientation of ordered biological macromolecules. To extend the adoption of the technique, it should be easily integrated onto commerci...

Full description

Bibliographic Details
Main Authors: Elisabeth I Romijn, Andreas Finnøy, Rajesh Kumar, Magnus B Lilledahl
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5892897?pdf=render
id doaj-f8e98ccd578341ae8c13d508aec772c6
record_format Article
spelling doaj-f8e98ccd578341ae8c13d508aec772c62020-11-25T00:40:42ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-01134e019502710.1371/journal.pone.0195027Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.Elisabeth I RomijnAndreas FinnøyRajesh KumarMagnus B LilledahlPolarization-resolved second harmonic generation (P-SHG) microscopy has evolved as a promising technique to reveal subresolution information about the structure and orientation of ordered biological macromolecules. To extend the adoption of the technique, it should be easily integrated onto commercial laser scanning microscopes. Furthermore, procedures for easy calibration and assessment of measurement accuracy are essential, and measurements should be fully automated to allow for analysis of large quantities of samples. In this paper we present a setup for P-SHG which is readily incorporated on commercial multiphoton microscopes. The entire system is completely automated which allows for rapid calibration through the freely available software and for automated imaging for different polarization measurements, including linear and circular polarization of the excitation beam. The results show that calibration settings are highly system dependent. We also show that the accuracy of the polarization control is easily quantified and that it varies between systems. The accuracy can be tuned by iterative alignment of optics or a more fine-grained calibration procedure. Images of real samples show that the red accuracy of the results is easily visualized with the automated setup. Through this system we believe that P-SHG could develop a wider adoption in biomedical applications.http://europepmc.org/articles/PMC5892897?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Elisabeth I Romijn
Andreas Finnøy
Rajesh Kumar
Magnus B Lilledahl
spellingShingle Elisabeth I Romijn
Andreas Finnøy
Rajesh Kumar
Magnus B Lilledahl
Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.
PLoS ONE
author_facet Elisabeth I Romijn
Andreas Finnøy
Rajesh Kumar
Magnus B Lilledahl
author_sort Elisabeth I Romijn
title Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.
title_short Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.
title_full Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.
title_fullStr Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.
title_full_unstemmed Automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.
title_sort automated calibration and control for polarization-resolved second harmonic generation on commercial microscopes.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2018-01-01
description Polarization-resolved second harmonic generation (P-SHG) microscopy has evolved as a promising technique to reveal subresolution information about the structure and orientation of ordered biological macromolecules. To extend the adoption of the technique, it should be easily integrated onto commercial laser scanning microscopes. Furthermore, procedures for easy calibration and assessment of measurement accuracy are essential, and measurements should be fully automated to allow for analysis of large quantities of samples. In this paper we present a setup for P-SHG which is readily incorporated on commercial multiphoton microscopes. The entire system is completely automated which allows for rapid calibration through the freely available software and for automated imaging for different polarization measurements, including linear and circular polarization of the excitation beam. The results show that calibration settings are highly system dependent. We also show that the accuracy of the polarization control is easily quantified and that it varies between systems. The accuracy can be tuned by iterative alignment of optics or a more fine-grained calibration procedure. Images of real samples show that the red accuracy of the results is easily visualized with the automated setup. Through this system we believe that P-SHG could develop a wider adoption in biomedical applications.
url http://europepmc.org/articles/PMC5892897?pdf=render
work_keys_str_mv AT elisabethiromijn automatedcalibrationandcontrolforpolarizationresolvedsecondharmonicgenerationoncommercialmicroscopes
AT andreasfinnøy automatedcalibrationandcontrolforpolarizationresolvedsecondharmonicgenerationoncommercialmicroscopes
AT rajeshkumar automatedcalibrationandcontrolforpolarizationresolvedsecondharmonicgenerationoncommercialmicroscopes
AT magnusblilledahl automatedcalibrationandcontrolforpolarizationresolvedsecondharmonicgenerationoncommercialmicroscopes
_version_ 1725288543554633728