Some particular design considerations for optimum utilization of under floor heating systems
This paper aims at studying the thermal behavior of an under floor heating system via CFD calculations. The results have discussed some important parameters that need to be controlled for an appropriate operation of the system. These parameters include the velocity inside the pipes, inlet temperatur...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2018-09-01
|
Series: | Case Studies in Thermal Engineering |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2214157X1830011X |
id |
doaj-f8a0e8fa13fc49949b37147c96653463 |
---|---|
record_format |
Article |
spelling |
doaj-f8a0e8fa13fc49949b37147c966534632020-11-24T23:01:14ZengElsevierCase Studies in Thermal Engineering2214-157X2018-09-0112423432Some particular design considerations for optimum utilization of under floor heating systemsS. Oubenmoh0A. Allouhi1A. Ait Mssad2R. Saadani3T. Kousksou4M. Rahmoune5M. Bentaleb6Laboratoire d′Etude des Matériaux Avancés et Applications, FS - EST Meknès, Université Moulay Ismail, Avenue Zitoune, BP 11201 Meknès, MoroccoEcole Supérieure de Technologie de Fès, USM.B.A, Route d′Imouzzer, BP 2427 Morocco; Corresponding author.Ecole Supérieure de Technologie de Fès, USM.B.A, Route d′Imouzzer, BP 2427 MoroccoLaboratoire d′Etude des Matériaux Avancés et Applications, FS - EST Meknès, Université Moulay Ismail, Avenue Zitoune, BP 11201 Meknès, MoroccoUniversité de Pau et des Pays de l′Adour, Laboratoire des Sciences pour l′Ingénieur Appliquées à la Mécanique et au Génie Electrique (SIAME), IFR – A. Jules Ferry, 64000 Pau, FranceLaboratoire d′Etude des Matériaux Avancés et Applications, FS - EST Meknès, Université Moulay Ismail, Avenue Zitoune, BP 11201 Meknès, MoroccoLaboratoire d′Etude des Matériaux Avancés et Applications, FS - EST Meknès, Université Moulay Ismail, Avenue Zitoune, BP 11201 Meknès, MoroccoThis paper aims at studying the thermal behavior of an under floor heating system via CFD calculations. The results have discussed some important parameters that need to be controlled for an appropriate operation of the system. These parameters include the velocity inside the pipes, inlet temperatures and the patterns of the tubing form. A new parameter to measure the floor thermal homogeneity has been introduced and evaluated. It is found that, generally, the modulated spiral configuration is the best configuration allowing less pressure losses and better thermal homogenization. Keywords: Under-floor heating, Design, Temperature distribution, Thermal homogenization, Configurationhttp://www.sciencedirect.com/science/article/pii/S2214157X1830011X |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
S. Oubenmoh A. Allouhi A. Ait Mssad R. Saadani T. Kousksou M. Rahmoune M. Bentaleb |
spellingShingle |
S. Oubenmoh A. Allouhi A. Ait Mssad R. Saadani T. Kousksou M. Rahmoune M. Bentaleb Some particular design considerations for optimum utilization of under floor heating systems Case Studies in Thermal Engineering |
author_facet |
S. Oubenmoh A. Allouhi A. Ait Mssad R. Saadani T. Kousksou M. Rahmoune M. Bentaleb |
author_sort |
S. Oubenmoh |
title |
Some particular design considerations for optimum utilization of under floor heating systems |
title_short |
Some particular design considerations for optimum utilization of under floor heating systems |
title_full |
Some particular design considerations for optimum utilization of under floor heating systems |
title_fullStr |
Some particular design considerations for optimum utilization of under floor heating systems |
title_full_unstemmed |
Some particular design considerations for optimum utilization of under floor heating systems |
title_sort |
some particular design considerations for optimum utilization of under floor heating systems |
publisher |
Elsevier |
series |
Case Studies in Thermal Engineering |
issn |
2214-157X |
publishDate |
2018-09-01 |
description |
This paper aims at studying the thermal behavior of an under floor heating system via CFD calculations. The results have discussed some important parameters that need to be controlled for an appropriate operation of the system. These parameters include the velocity inside the pipes, inlet temperatures and the patterns of the tubing form. A new parameter to measure the floor thermal homogeneity has been introduced and evaluated. It is found that, generally, the modulated spiral configuration is the best configuration allowing less pressure losses and better thermal homogenization. Keywords: Under-floor heating, Design, Temperature distribution, Thermal homogenization, Configuration |
url |
http://www.sciencedirect.com/science/article/pii/S2214157X1830011X |
work_keys_str_mv |
AT soubenmoh someparticulardesignconsiderationsforoptimumutilizationofunderfloorheatingsystems AT aallouhi someparticulardesignconsiderationsforoptimumutilizationofunderfloorheatingsystems AT aaitmssad someparticulardesignconsiderationsforoptimumutilizationofunderfloorheatingsystems AT rsaadani someparticulardesignconsiderationsforoptimumutilizationofunderfloorheatingsystems AT tkousksou someparticulardesignconsiderationsforoptimumutilizationofunderfloorheatingsystems AT mrahmoune someparticulardesignconsiderationsforoptimumutilizationofunderfloorheatingsystems AT mbentaleb someparticulardesignconsiderationsforoptimumutilizationofunderfloorheatingsystems |
_version_ |
1725640235356782592 |