Biocide-mediated corrosion of coiled tubing.

Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable...

Full description

Bibliographic Details
Main Authors: Mohita Sharma, Dongshan An, Tao Liu, Tijan Pinnock, Frank Cheng, Gerrit Voordouw
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2017-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5528904?pdf=render
id doaj-f89b9c61774b4bc58bdce2a5017f84cf
record_format Article
spelling doaj-f89b9c61774b4bc58bdce2a5017f84cf2020-11-25T01:36:42ZengPublic Library of Science (PLoS)PLoS ONE1932-62032017-01-01127e018193410.1371/journal.pone.0181934Biocide-mediated corrosion of coiled tubing.Mohita SharmaDongshan AnTao LiuTijan PinnockFrank ChengGerrit VoordouwCoiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons did not lead to big changes in microbial community composition. In contrast other field water samples had most probable numbers of APB of 102/mL to 107/mL and incubation of these field water samples with carbon steel beads or coupons often gave large changes in microbial community composition. HPLC analysis indicated that all field water samples had elevated concentrations of bromide (average 1.6 mM), which may be derived from bronopol, which was used as a biocide. S19 had the highest bromide concentration (4.2 mM) and was the only water sample with a high concentration of active bronopol (13.8 mM, 2760 ppm). Corrosion rates increased linearly with bronopol concentration, as determined by weight loss of carbon steel beads, for experiments with S19, with filtered S19 and with bronopol dissolved in defined medium. This indicated that the high corrosion rate found for S19 was due to its high bronopol concentration. The corrosion rate of coiled tubing coupons also increased linearly with bronopol concentration as determined by electrochemical methods. Profilometry measurements also showed formation of multiple pits on the surface of coiled tubing coupon with an average pit depth of 60 μm after 1 week of incubation with 1 mM bronopol. At the recommended dosage of 100 ppm the corrosiveness of bronopol towards carbon steel beads was modest (0.011 mm/yr). Higher concentrations, resulting if biocide is added repeatedly as commonly done in shale gas operations, are more corrosive and should be avoided. Overdosing may be avoided by assaying the presence of residual biocide by HPLC, rather than by assaying the presence of residual surviving bacteria.http://europepmc.org/articles/PMC5528904?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Mohita Sharma
Dongshan An
Tao Liu
Tijan Pinnock
Frank Cheng
Gerrit Voordouw
spellingShingle Mohita Sharma
Dongshan An
Tao Liu
Tijan Pinnock
Frank Cheng
Gerrit Voordouw
Biocide-mediated corrosion of coiled tubing.
PLoS ONE
author_facet Mohita Sharma
Dongshan An
Tao Liu
Tijan Pinnock
Frank Cheng
Gerrit Voordouw
author_sort Mohita Sharma
title Biocide-mediated corrosion of coiled tubing.
title_short Biocide-mediated corrosion of coiled tubing.
title_full Biocide-mediated corrosion of coiled tubing.
title_fullStr Biocide-mediated corrosion of coiled tubing.
title_full_unstemmed Biocide-mediated corrosion of coiled tubing.
title_sort biocide-mediated corrosion of coiled tubing.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2017-01-01
description Coiled tubing corrosion was investigated for 16 field water samples (S5 to S20) from a Canadian shale gas field. Weight loss corrosion rates of carbon steel beads incubated with these field water samples averaged 0.2 mm/yr, but injection water sample S19 had 1.25±0.07 mm/yr. S19 had a most probable number of zero acid-producing bacteria and incubation of S19 with carbon steel beads or coupons did not lead to big changes in microbial community composition. In contrast other field water samples had most probable numbers of APB of 102/mL to 107/mL and incubation of these field water samples with carbon steel beads or coupons often gave large changes in microbial community composition. HPLC analysis indicated that all field water samples had elevated concentrations of bromide (average 1.6 mM), which may be derived from bronopol, which was used as a biocide. S19 had the highest bromide concentration (4.2 mM) and was the only water sample with a high concentration of active bronopol (13.8 mM, 2760 ppm). Corrosion rates increased linearly with bronopol concentration, as determined by weight loss of carbon steel beads, for experiments with S19, with filtered S19 and with bronopol dissolved in defined medium. This indicated that the high corrosion rate found for S19 was due to its high bronopol concentration. The corrosion rate of coiled tubing coupons also increased linearly with bronopol concentration as determined by electrochemical methods. Profilometry measurements also showed formation of multiple pits on the surface of coiled tubing coupon with an average pit depth of 60 μm after 1 week of incubation with 1 mM bronopol. At the recommended dosage of 100 ppm the corrosiveness of bronopol towards carbon steel beads was modest (0.011 mm/yr). Higher concentrations, resulting if biocide is added repeatedly as commonly done in shale gas operations, are more corrosive and should be avoided. Overdosing may be avoided by assaying the presence of residual biocide by HPLC, rather than by assaying the presence of residual surviving bacteria.
url http://europepmc.org/articles/PMC5528904?pdf=render
work_keys_str_mv AT mohitasharma biocidemediatedcorrosionofcoiledtubing
AT dongshanan biocidemediatedcorrosionofcoiledtubing
AT taoliu biocidemediatedcorrosionofcoiledtubing
AT tijanpinnock biocidemediatedcorrosionofcoiledtubing
AT frankcheng biocidemediatedcorrosionofcoiledtubing
AT gerritvoordouw biocidemediatedcorrosionofcoiledtubing
_version_ 1725061524276379648