Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model
Background. Early radiological diagnosis and continual monitoring are of ultimate importance for timely treatment of delayed union, nonunion, and infection after bone fracture surgery. Although magnetic resonance imaging (MRI) could provide superior detailed images compared with X-ray and computed t...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2016-01-01
|
Series: | BioMed Research International |
Online Access: | http://dx.doi.org/10.1155/2016/1429892 |
id |
doaj-f817d81216934091b1167bcec5742ad9 |
---|---|
record_format |
Article |
spelling |
doaj-f817d81216934091b1167bcec5742ad92020-11-24T21:15:42ZengHindawi LimitedBioMed Research International2314-61332314-61412016-01-01201610.1155/2016/14298921429892Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal ModelZhe Jin0Yuheng Guan1Guibo Yu2Yu Sun3Department of Orthopaedics, First Hospital of China Medical University, 155 Nan Jing Bei Street, Heping District, Shenyang 110001, ChinaDepartment of Radiological Diagnosis and Interventional Treatment, First Hospital of China Medical University, Shenyang 110001, ChinaDepartment of Radiological Diagnosis and Interventional Treatment, First Hospital of China Medical University, Shenyang 110001, ChinaDepartment of Orthopaedics, First Hospital of China Medical University, 155 Nan Jing Bei Street, Heping District, Shenyang 110001, ChinaBackground. Early radiological diagnosis and continual monitoring are of ultimate importance for timely treatment of delayed union, nonunion, and infection after bone fracture surgery. Although magnetic resonance imaging (MRI) could provide superior detailed images compared with X-ray and computed tomography (CT) without ionizing radiation, metal implants used for fracture fixation lead to abundant artifacts on MRI and thus prohibit accurate interpretation. The authors develop a novel intramedullary fixation model of rat femoral fracture using polyetheretherketone (PEEK) threaded rods and investigate its feasibility for in vivo MRI monitoring of the fracture healing process without artifact. Methods. Femoral fractures of 3 adult male Sprague-Dawley rats were fixed with intramedullary PEEK threaded rods. X-ray and MRI examinations were performed at day 7 postoperatively. Radiological images were analyzed for the existence of artifact interruption and postoperative changes in bone and peripheral soft tissue. Results. Postoperative plain film revealed no loss of reduction. MRI images illustrated the whole length of femur and peripheral tissue without artifact interruption, and the cortical bone, implanted PEEK rod, and soft tissue were clearly illustrated. Conclusion. This preliminary study introduced a novel rat model for in vivo MRI monitoring of the fracture healing process without metal artifact, by using intramedullary fixation of femur with PEEK threaded rod.http://dx.doi.org/10.1155/2016/1429892 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Zhe Jin Yuheng Guan Guibo Yu Yu Sun |
spellingShingle |
Zhe Jin Yuheng Guan Guibo Yu Yu Sun Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model BioMed Research International |
author_facet |
Zhe Jin Yuheng Guan Guibo Yu Yu Sun |
author_sort |
Zhe Jin |
title |
Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model |
title_short |
Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model |
title_full |
Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model |
title_fullStr |
Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model |
title_full_unstemmed |
Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model |
title_sort |
magnetic resonance imaging of postoperative fracture healing process without metal artifact: a preliminary report of a novel animal model |
publisher |
Hindawi Limited |
series |
BioMed Research International |
issn |
2314-6133 2314-6141 |
publishDate |
2016-01-01 |
description |
Background. Early radiological diagnosis and continual monitoring are of ultimate importance for timely treatment of delayed union, nonunion, and infection after bone fracture surgery. Although magnetic resonance imaging (MRI) could provide superior detailed images compared with X-ray and computed tomography (CT) without ionizing radiation, metal implants used for fracture fixation lead to abundant artifacts on MRI and thus prohibit accurate interpretation. The authors develop a novel intramedullary fixation model of rat femoral fracture using polyetheretherketone (PEEK) threaded rods and investigate its feasibility for in vivo MRI monitoring of the fracture healing process without artifact. Methods. Femoral fractures of 3 adult male Sprague-Dawley rats were fixed with intramedullary PEEK threaded rods. X-ray and MRI examinations were performed at day 7 postoperatively. Radiological images were analyzed for the existence of artifact interruption and postoperative changes in bone and peripheral soft tissue. Results. Postoperative plain film revealed no loss of reduction. MRI images illustrated the whole length of femur and peripheral tissue without artifact interruption, and the cortical bone, implanted PEEK rod, and soft tissue were clearly illustrated. Conclusion. This preliminary study introduced a novel rat model for in vivo MRI monitoring of the fracture healing process without metal artifact, by using intramedullary fixation of femur with PEEK threaded rod. |
url |
http://dx.doi.org/10.1155/2016/1429892 |
work_keys_str_mv |
AT zhejin magneticresonanceimagingofpostoperativefracturehealingprocesswithoutmetalartifactapreliminaryreportofanovelanimalmodel AT yuhengguan magneticresonanceimagingofpostoperativefracturehealingprocesswithoutmetalartifactapreliminaryreportofanovelanimalmodel AT guiboyu magneticresonanceimagingofpostoperativefracturehealingprocesswithoutmetalartifactapreliminaryreportofanovelanimalmodel AT yusun magneticresonanceimagingofpostoperativefracturehealingprocesswithoutmetalartifactapreliminaryreportofanovelanimalmodel |
_version_ |
1716744358479265792 |