Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
National Technical University "Kharkiv Polytechnic Institute"
2021-06-01
|
Series: | Електротехніка і електромеханіка |
Subjects: | |
Online Access: | http://eie.khpi.edu.ua/article/view/234463/233444 |
id |
doaj-f7a5277160fb4065b92474654a3248a1 |
---|---|
record_format |
Article |
spelling |
doaj-f7a5277160fb4065b92474654a3248a12021-07-02T21:16:46ZengNational Technical University "Kharkiv Polytechnic Institute"Електротехніка і електромеханіка2074-272X2309-34042021-06-013424610.20998/2074-272X.2021.3.07Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum dischargerL. A. Ljutenko0https://orcid.org/0000-0002-7860-3835V. M. Mikhailov1https://orcid.org/0000-0001-7989-5932National Technical University «Kharkiv Polytechnic Institute», UkraineNational Technical University «Kharkiv Polytechnic Institute», UkrainePurpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion of cylindrical thin-walled tubular workpieces using an external coil. Methodology. High voltage magnetic-pulse installation of NTU «KhPI» with controlled vacuum discharger, multiturn coil with inside dielectrical die and inside aluminum alloy workpiece are used. The capacitance and charge voltage of capacitive energy storage are changed. Discharge current pulses are measured by Rogowski coil and the oscillograph. Results. Parts of complicated shape are made by expansion of cylindrical tubular workpieces with help of external coil. Pressed metallic tubular part is removable from inner dielectric rod. Originality. The frequency of «cut» pulse is defined by negative magnetic field pressure amplitude. It is shown that we must coordinate this frequency and charge voltage with capacitive storage parameters by high probability of pulse «cut». Practical value. It is shown how to use installations with controlled vacuum dischargers in magnetic forming technology based on «cut» pulses.http://eie.khpi.edu.ua/article/view/234463/233444high-voltage magnetic-pulse installationscapacitive energy storagecontrolled vacuum dischargercurrent pulse «cut»probability of «cut»external coilexpansion of cylindrical tubular workpiecepart of complicated shape |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
L. A. Ljutenko V. M. Mikhailov |
spellingShingle |
L. A. Ljutenko V. M. Mikhailov Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger Електротехніка і електромеханіка high-voltage magnetic-pulse installations capacitive energy storage controlled vacuum discharger current pulse «cut» probability of «cut» external coil expansion of cylindrical tubular workpiece part of complicated shape |
author_facet |
L. A. Ljutenko V. M. Mikhailov |
author_sort |
L. A. Ljutenko |
title |
Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger |
title_short |
Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger |
title_full |
Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger |
title_fullStr |
Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger |
title_full_unstemmed |
Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger |
title_sort |
expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger |
publisher |
National Technical University "Kharkiv Polytechnic Institute" |
series |
Електротехніка і електромеханіка |
issn |
2074-272X 2309-3404 |
publishDate |
2021-06-01 |
description |
Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion of cylindrical thin-walled tubular workpieces using an external coil. Methodology. High voltage magnetic-pulse installation of NTU «KhPI» with controlled vacuum discharger, multiturn coil with inside dielectrical die and inside aluminum alloy workpiece are used. The capacitance and charge voltage of capacitive energy storage are changed. Discharge current pulses are measured by Rogowski coil and the oscillograph. Results. Parts of complicated shape are made by expansion of cylindrical tubular workpieces with help of external coil. Pressed metallic tubular part is removable from inner dielectric rod. Originality. The frequency of «cut» pulse is defined by negative magnetic field pressure amplitude. It is shown that we must coordinate this frequency and charge voltage with capacitive storage parameters by high probability of pulse «cut». Practical value. It is shown how to use installations with controlled vacuum dischargers in magnetic forming technology based on «cut» pulses. |
topic |
high-voltage magnetic-pulse installations capacitive energy storage controlled vacuum discharger current pulse «cut» probability of «cut» external coil expansion of cylindrical tubular workpiece part of complicated shape |
url |
http://eie.khpi.edu.ua/article/view/234463/233444 |
work_keys_str_mv |
AT laljutenko expansionofcylindricaltubularworkpiecesonhighvoltagemagneticpulseinstallationwithcontrolledvacuumdischarger AT vmmikhailov expansionofcylindricaltubularworkpiecesonhighvoltagemagneticpulseinstallationwithcontrolledvacuumdischarger |
_version_ |
1721322226722013184 |