Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger

Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion...

Full description

Bibliographic Details
Main Authors: L. A. Ljutenko, V. M. Mikhailov
Format: Article
Language:English
Published: National Technical University "Kharkiv Polytechnic Institute" 2021-06-01
Series:Електротехніка і електромеханіка
Subjects:
Online Access:http://eie.khpi.edu.ua/article/view/234463/233444
id doaj-f7a5277160fb4065b92474654a3248a1
record_format Article
spelling doaj-f7a5277160fb4065b92474654a3248a12021-07-02T21:16:46ZengNational Technical University "Kharkiv Polytechnic Institute"Електротехніка і електромеханіка2074-272X2309-34042021-06-013424610.20998/2074-272X.2021.3.07Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum dischargerL. A. Ljutenko0https://orcid.org/0000-0002-7860-3835V. M. Mikhailov1https://orcid.org/0000-0001-7989-5932National Technical University «Kharkiv Polytechnic Institute», UkraineNational Technical University «Kharkiv Polytechnic Institute», UkrainePurpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion of cylindrical thin-walled tubular workpieces using an external coil. Methodology. High voltage magnetic-pulse installation of NTU «KhPI» with controlled vacuum discharger, multiturn coil with inside dielectrical die and inside aluminum alloy workpiece are used. The capacitance and charge voltage of capacitive energy storage are changed. Discharge current pulses are measured by Rogowski coil and the oscillograph. Results. Parts of complicated shape are made by expansion of cylindrical tubular workpieces with help of external coil. Pressed metallic tubular part is removable from inner dielectric rod. Originality. The frequency of «cut» pulse is defined by negative magnetic field pressure amplitude. It is shown that we must coordinate this frequency and charge voltage with capacitive storage parameters by high probability of pulse «cut». Practical value. It is shown how to use installations with controlled vacuum dischargers in magnetic forming technology based on «cut» pulses.http://eie.khpi.edu.ua/article/view/234463/233444high-voltage magnetic-pulse installationscapacitive energy storagecontrolled vacuum dischargercurrent pulse «cut»probability of «cut»external coilexpansion of cylindrical tubular workpiecepart of complicated shape
collection DOAJ
language English
format Article
sources DOAJ
author L. A. Ljutenko
V. M. Mikhailov
spellingShingle L. A. Ljutenko
V. M. Mikhailov
Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
Електротехніка і електромеханіка
high-voltage magnetic-pulse installations
capacitive energy storage
controlled vacuum discharger
current pulse «cut»
probability of «cut»
external coil
expansion of cylindrical tubular workpiece
part of complicated shape
author_facet L. A. Ljutenko
V. M. Mikhailov
author_sort L. A. Ljutenko
title Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_short Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_full Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_fullStr Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_full_unstemmed Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
title_sort expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger
publisher National Technical University "Kharkiv Polytechnic Institute"
series Електротехніка і електромеханіка
issn 2074-272X
2309-3404
publishDate 2021-06-01
description Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of the discharge current pulses and the expansion of cylindrical thin-walled tubular workpieces using an external coil. Methodology. High voltage magnetic-pulse installation of NTU «KhPI» with controlled vacuum discharger, multiturn coil with inside dielectrical die and inside aluminum alloy workpiece are used. The capacitance and charge voltage of capacitive energy storage are changed. Discharge current pulses are measured by Rogowski coil and the oscillograph. Results. Parts of complicated shape are made by expansion of cylindrical tubular workpieces with help of external coil. Pressed metallic tubular part is removable from inner dielectric rod. Originality. The frequency of «cut» pulse is defined by negative magnetic field pressure amplitude. It is shown that we must coordinate this frequency and charge voltage with capacitive storage parameters by high probability of pulse «cut». Practical value. It is shown how to use installations with controlled vacuum dischargers in magnetic forming technology based on «cut» pulses.
topic high-voltage magnetic-pulse installations
capacitive energy storage
controlled vacuum discharger
current pulse «cut»
probability of «cut»
external coil
expansion of cylindrical tubular workpiece
part of complicated shape
url http://eie.khpi.edu.ua/article/view/234463/233444
work_keys_str_mv AT laljutenko expansionofcylindricaltubularworkpiecesonhighvoltagemagneticpulseinstallationwithcontrolledvacuumdischarger
AT vmmikhailov expansionofcylindricaltubularworkpiecesonhighvoltagemagneticpulseinstallationwithcontrolledvacuumdischarger
_version_ 1721322226722013184