Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of Microwells
Many conventional biochemical assays are performed using populations of cells to determine their quantitative biomolecular profiles. However, population averages do not reflect actual physiological processes in individual cells, which occur either on short time scales or nonsynchronously. Therefore,...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2011-12-01
|
Series: | Sensors |
Subjects: | |
Online Access: | http://www.mdpi.com/1424-8220/12/1/347/ |
id |
doaj-f7609d49dcac4045bac9c3959ff9f5aa |
---|---|
record_format |
Article |
spelling |
doaj-f7609d49dcac4045bac9c3959ff9f5aa2020-11-25T00:55:22ZengMDPI AGSensors1424-82202011-12-0112134735810.3390/s120100347Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of MicrowellsNikolay A. MaslovChun-Ping JenJu-Hsiu HsiaoMany conventional biochemical assays are performed using populations of cells to determine their quantitative biomolecular profiles. However, population averages do not reflect actual physiological processes in individual cells, which occur either on short time scales or nonsynchronously. Therefore, accurate analysis at the single-cell level has become a highly attractive tool for investigating cellular content. Microfluidic chips with arrays of microwells were developed for single-cell chemical lysis in the present study. The cellular occupancy in 30-mm-diameter microwells (91.45%) was higher than that in 20-mm-diameter microwells (83.19%) at an injection flow rate of 2.8 mL/min. However, most of the occupied 20-mm-diameter microwells contained individual cells. The results of chemical lysis experiments at the single-cell level indicate that cell membranes were gradually lysed as the lysis buffer was injected; they were fully lysed after 12 s. Single-cell chemical lysis was demonstrated in the proposed microfluidic chip, which is suitable for high-throughput cell lysis.http://www.mdpi.com/1424-8220/12/1/347/microwellsingle-cellcell lysismicrofluidics |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Nikolay A. Maslov Chun-Ping Jen Ju-Hsiu Hsiao |
spellingShingle |
Nikolay A. Maslov Chun-Ping Jen Ju-Hsiu Hsiao Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of Microwells Sensors microwell single-cell cell lysis microfluidics |
author_facet |
Nikolay A. Maslov Chun-Ping Jen Ju-Hsiu Hsiao |
author_sort |
Nikolay A. Maslov |
title |
Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of Microwells |
title_short |
Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of Microwells |
title_full |
Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of Microwells |
title_fullStr |
Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of Microwells |
title_full_unstemmed |
Single-Cell Chemical Lysis on Microfluidic Chips with Arrays of Microwells |
title_sort |
single-cell chemical lysis on microfluidic chips with arrays of microwells |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2011-12-01 |
description |
Many conventional biochemical assays are performed using populations of cells to determine their quantitative biomolecular profiles. However, population averages do not reflect actual physiological processes in individual cells, which occur either on short time scales or nonsynchronously. Therefore, accurate analysis at the single-cell level has become a highly attractive tool for investigating cellular content. Microfluidic chips with arrays of microwells were developed for single-cell chemical lysis in the present study. The cellular occupancy in 30-mm-diameter microwells (91.45%) was higher than that in 20-mm-diameter microwells (83.19%) at an injection flow rate of 2.8 mL/min. However, most of the occupied 20-mm-diameter microwells contained individual cells. The results of chemical lysis experiments at the single-cell level indicate that cell membranes were gradually lysed as the lysis buffer was injected; they were fully lysed after 12 s. Single-cell chemical lysis was demonstrated in the proposed microfluidic chip, which is suitable for high-throughput cell lysis. |
topic |
microwell single-cell cell lysis microfluidics |
url |
http://www.mdpi.com/1424-8220/12/1/347/ |
work_keys_str_mv |
AT nikolayamaslov singlecellchemicallysisonmicrofluidicchipswitharraysofmicrowells AT chunpingjen singlecellchemicallysisonmicrofluidicchipswitharraysofmicrowells AT juhsiuhsiao singlecellchemicallysisonmicrofluidicchipswitharraysofmicrowells |
_version_ |
1725230537255157760 |