THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY

As a rule, methods evaluating the need and volume of fluid therapy are expensive, they require relevant equipment and it is not always available in hospitals; therefore it has been proposed to use mobile devices with Capstesia software to capture the image of the arterial pressure curve from the mon...

Full description

Bibliographic Details
Main Authors: R. S. Perfiliev, Yu. V. Skripkin, A. M. Ovezov, V. V. Likhvantsev
Format: Article
Language:Russian
Published: NEW TERRA Publishing House 2018-01-01
Series:Вестник анестезиологии и реаниматологии
Subjects:
Online Access:https://www.vair-journal.com/jour/article/view/194
id doaj-f74f402bee8b4478a5cdf72c874d25b4
record_format Article
spelling doaj-f74f402bee8b4478a5cdf72c874d25b42021-07-28T13:37:19ZrusNEW TERRA Publishing HouseВестник анестезиологии и реаниматологии2078-56582541-86532018-01-01146525610.21292/2078-5658-2017-14-6-52-56194THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPYR. S. Perfiliev0Yu. V. Skripkin1A. M. Ovezov2V. V. Likhvantsev3Moscow Regional Research Clinical Institute named after M. F. Vladimirsky, MoscowMoscow Regional Research Clinical Institute named after M. F. Vladimirsky, MoscowMoscow Regional Research Clinical Institute named after M. F. Vladimirsky, MoscowMoscow Regional Research Clinical Institute named after M. F. Vladimirsky, MoscowAs a rule, methods evaluating the need and volume of fluid therapy are expensive, they require relevant equipment and it is not always available in hospitals; therefore it has been proposed to use mobile devices with Capstesia software to capture the image of the arterial pressure curve from the monitor screen and to analyze it in order to determine the variability of the pulse pressure (PPV). Materials and subjects. The efficiency of defining the need for fluid therapy using Capstesia was assessed in the clinical settings. 95 integrated measurements were performed in 19 patients with septic shock, who had the catheter installed to monitor the fluid therapy for trans-pulmonary thermodilution; and the PiCCO2 monitor was used. Simultaneously, the test with the volemic load (VLT) was conducted and PPV was tested with the aid of Capstesia. Results. The analysis revealed significantly higher mean differences and ranges of levels' consistency when testing PPV by Capstesia, in which the error rate was also higher than the acceptable level and it made 56%, whereas the method of VLT had only 20% of errors and significantly smaller mean difference and ranges of consistency levels.https://www.vair-journal.com/jour/article/view/194variability of systolic outputvariability of pulse pressureinfusion therapy
collection DOAJ
language Russian
format Article
sources DOAJ
author R. S. Perfiliev
Yu. V. Skripkin
A. M. Ovezov
V. V. Likhvantsev
spellingShingle R. S. Perfiliev
Yu. V. Skripkin
A. M. Ovezov
V. V. Likhvantsev
THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY
Вестник анестезиологии и реаниматологии
variability of systolic output
variability of pulse pressure
infusion therapy
author_facet R. S. Perfiliev
Yu. V. Skripkin
A. M. Ovezov
V. V. Likhvantsev
author_sort R. S. Perfiliev
title THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY
title_short THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY
title_full THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY
title_fullStr THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY
title_full_unstemmed THE NOVEL MOBILE DEVICE APPLICATION OF CAPSTESIA AIMED TO DEFINE THE NEED FOR FLUID THERAPY
title_sort novel mobile device application of capstesia aimed to define the need for fluid therapy
publisher NEW TERRA Publishing House
series Вестник анестезиологии и реаниматологии
issn 2078-5658
2541-8653
publishDate 2018-01-01
description As a rule, methods evaluating the need and volume of fluid therapy are expensive, they require relevant equipment and it is not always available in hospitals; therefore it has been proposed to use mobile devices with Capstesia software to capture the image of the arterial pressure curve from the monitor screen and to analyze it in order to determine the variability of the pulse pressure (PPV). Materials and subjects. The efficiency of defining the need for fluid therapy using Capstesia was assessed in the clinical settings. 95 integrated measurements were performed in 19 patients with septic shock, who had the catheter installed to monitor the fluid therapy for trans-pulmonary thermodilution; and the PiCCO2 monitor was used. Simultaneously, the test with the volemic load (VLT) was conducted and PPV was tested with the aid of Capstesia. Results. The analysis revealed significantly higher mean differences and ranges of levels' consistency when testing PPV by Capstesia, in which the error rate was also higher than the acceptable level and it made 56%, whereas the method of VLT had only 20% of errors and significantly smaller mean difference and ranges of consistency levels.
topic variability of systolic output
variability of pulse pressure
infusion therapy
url https://www.vair-journal.com/jour/article/view/194
work_keys_str_mv AT rsperfiliev thenovelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
AT yuvskripkin thenovelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
AT amovezov thenovelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
AT vvlikhvantsev thenovelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
AT rsperfiliev novelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
AT yuvskripkin novelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
AT amovezov novelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
AT vvlikhvantsev novelmobiledeviceapplicationofcapstesiaaimedtodefinetheneedforfluidtherapy
_version_ 1721272499460636672