The problem of sprinkler reliability

Sprinkler systems allow a considerable reduction of fire risk in buildings. Unfortunately, sprinklers are not failsafe technical systems. Relatively high rates of sprinkler failures evoke the problem of reliability. A solution to this problem is considered from several viewpoints. The diversity of...

Full description

Bibliographic Details
Main Author: Jurgita Šakėnaitė
Format: Article
Language:English
Published: Vilnius Gediminas Technical University 2011-04-01
Series:Mokslas: Lietuvos Ateitis
Subjects:
Online Access:https://www.jbem.vgtu.lt/index.php/MLA/article/view/10652
id doaj-f6e0ecda259643f79456bda59b41b7db
record_format Article
spelling doaj-f6e0ecda259643f79456bda59b41b7db2021-05-02T14:01:11ZengVilnius Gediminas Technical UniversityMokslas: Lietuvos Ateitis2029-23412029-22522011-04-011510.3846/mla.2009.5.07182The problem of sprinkler reliabilityJurgita Šakėnaitė0Vilniaus Gedimino technikos universitetas, Lithuania Sprinkler systems allow a considerable reduction of fire risk in buildings. Unfortunately, sprinklers are not failsafe technical systems. Relatively high rates of sprinkler failures evoke the problem of reliability. A solution to this problem is considered from several viewpoints. The diversity of sprinklers' failure modes is the first challenge for estimating reliability (failure probability). It is found that the use of the available data for estimation is problematic. The second challenge is that the published data is insufficiently described to allow a verification of its relevance to the specific case of failure probability estimation. It is suggested to apply the published data with partial relevance to Bayesian inference about failure probabilities. The data is used for developing prior distributions of the unknown values of the probabilities. Bayesian inference is carried out on the basis of binomial distribution used to model the operation of sprinklers on demand basis. A problem of aging and a possible increase in failure probability in the course of sprinkler service is shortly discussed. Article in English. Sprinklerių patikimumo problema Santrauka. Nagrinėta sprinklerių sistemų patikimumo vertinimo problema. Patikimumo matu laikoma sprinklerių atsako tikimybė. Rasta, kad šios tikimybės vertinimas yra sąlygiškai sudėtingas uždavinys. Sprinkleriai gali patirti atsaką labai įvairiais būdais. Be to, šis atsakas patiriamas retai. Tai lemia duomenų apie sprinklerių neįsijungimo gaisro metu negausumą, neleidžia vertinti atsako tikimybės, remiantis klasikiniu santykinio dažnio požiūriu. Patikimumo vertinimą komplikuoja tai, kad duomenys apie sprinklerių atsakus renkami gana nesistemingai, be teorinio pagrindo ir standartizavimo šalies, regiono ar pasaulio mastu. Duomenys paprastai fiksuojami pasyviai, kai sprinkleriai neįsijungia gaisro metu. Turimi empiriniai sprinklerių atsako dažniai gali būti naudojami kaip šiurkštūs tikimybių įverčiai. Juos galima taikyti Bajeso analizei, kai reikia formuoti apriorinį atsako tikimybės tankį. Šį tankį galima atnaujinti pasitelkiant negausius duomenis, surinktus konkrečioje šalyje, ir gautus stebint konkretaus tipo sprinklerius. Teorinis modelis kuriuo galima nusakyti sprinklerių atsakų tikėtinumą per pasirinktą gaisrų skaičių, yra binominis skirstinys. Sprinklerių atsako tikimybės vertinimą galima atlikti taikant standartinę binominio skirstinio parametro vertinimo procedūrą Bajeso statistikos metodais. Pagrindinė binominio skirstinio prielaida yra ta, kad sprinkleriai nesensta ir jų atsako tikimybė nesikeičia laikui bėgant. Galima spėsti, kad ši prielaida yra neteisinga. Deja, duomenų, kurie galėtų patvirtinti arba paneigti tą prielaidą, trūksta. Be tokių duomenų, nebus galima parinkti modelio, kuris nusako atsako tikimybės didėjimą sprinklerius eksploatuojant. Taigi sprinklerių senėjimas ir jų atsako tikimybės didėjimas tėra tik teorinė prielaida, kurią sunku įtraukti į sprinklerių patikimumo vertinimą. Reikšminiai žodžiai: sprinkleriai, gaisras, Bajeso požiūris, daugiakriterė atranka. https://www.jbem.vgtu.lt/index.php/MLA/article/view/10652spriklersfireBayesain approachmulti-attribute selection
collection DOAJ
language English
format Article
sources DOAJ
author Jurgita Šakėnaitė
spellingShingle Jurgita Šakėnaitė
The problem of sprinkler reliability
Mokslas: Lietuvos Ateitis
spriklers
fire
Bayesain approach
multi-attribute selection
author_facet Jurgita Šakėnaitė
author_sort Jurgita Šakėnaitė
title The problem of sprinkler reliability
title_short The problem of sprinkler reliability
title_full The problem of sprinkler reliability
title_fullStr The problem of sprinkler reliability
title_full_unstemmed The problem of sprinkler reliability
title_sort problem of sprinkler reliability
publisher Vilnius Gediminas Technical University
series Mokslas: Lietuvos Ateitis
issn 2029-2341
2029-2252
publishDate 2011-04-01
description Sprinkler systems allow a considerable reduction of fire risk in buildings. Unfortunately, sprinklers are not failsafe technical systems. Relatively high rates of sprinkler failures evoke the problem of reliability. A solution to this problem is considered from several viewpoints. The diversity of sprinklers' failure modes is the first challenge for estimating reliability (failure probability). It is found that the use of the available data for estimation is problematic. The second challenge is that the published data is insufficiently described to allow a verification of its relevance to the specific case of failure probability estimation. It is suggested to apply the published data with partial relevance to Bayesian inference about failure probabilities. The data is used for developing prior distributions of the unknown values of the probabilities. Bayesian inference is carried out on the basis of binomial distribution used to model the operation of sprinklers on demand basis. A problem of aging and a possible increase in failure probability in the course of sprinkler service is shortly discussed. Article in English. Sprinklerių patikimumo problema Santrauka. Nagrinėta sprinklerių sistemų patikimumo vertinimo problema. Patikimumo matu laikoma sprinklerių atsako tikimybė. Rasta, kad šios tikimybės vertinimas yra sąlygiškai sudėtingas uždavinys. Sprinkleriai gali patirti atsaką labai įvairiais būdais. Be to, šis atsakas patiriamas retai. Tai lemia duomenų apie sprinklerių neįsijungimo gaisro metu negausumą, neleidžia vertinti atsako tikimybės, remiantis klasikiniu santykinio dažnio požiūriu. Patikimumo vertinimą komplikuoja tai, kad duomenys apie sprinklerių atsakus renkami gana nesistemingai, be teorinio pagrindo ir standartizavimo šalies, regiono ar pasaulio mastu. Duomenys paprastai fiksuojami pasyviai, kai sprinkleriai neįsijungia gaisro metu. Turimi empiriniai sprinklerių atsako dažniai gali būti naudojami kaip šiurkštūs tikimybių įverčiai. Juos galima taikyti Bajeso analizei, kai reikia formuoti apriorinį atsako tikimybės tankį. Šį tankį galima atnaujinti pasitelkiant negausius duomenis, surinktus konkrečioje šalyje, ir gautus stebint konkretaus tipo sprinklerius. Teorinis modelis kuriuo galima nusakyti sprinklerių atsakų tikėtinumą per pasirinktą gaisrų skaičių, yra binominis skirstinys. Sprinklerių atsako tikimybės vertinimą galima atlikti taikant standartinę binominio skirstinio parametro vertinimo procedūrą Bajeso statistikos metodais. Pagrindinė binominio skirstinio prielaida yra ta, kad sprinkleriai nesensta ir jų atsako tikimybė nesikeičia laikui bėgant. Galima spėsti, kad ši prielaida yra neteisinga. Deja, duomenų, kurie galėtų patvirtinti arba paneigti tą prielaidą, trūksta. Be tokių duomenų, nebus galima parinkti modelio, kuris nusako atsako tikimybės didėjimą sprinklerius eksploatuojant. Taigi sprinklerių senėjimas ir jų atsako tikimybės didėjimas tėra tik teorinė prielaida, kurią sunku įtraukti į sprinklerių patikimumo vertinimą. Reikšminiai žodžiai: sprinkleriai, gaisras, Bajeso požiūris, daugiakriterė atranka.
topic spriklers
fire
Bayesain approach
multi-attribute selection
url https://www.jbem.vgtu.lt/index.php/MLA/article/view/10652
work_keys_str_mv AT jurgitasakenaite theproblemofsprinklerreliability
AT jurgitasakenaite problemofsprinklerreliability
_version_ 1721490906790494208