Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses

<p>Abstract</p> <p>Background</p> <p>To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume...

Full description

Bibliographic Details
Main Authors: Yavuz Melek, Pehlivan Berrin, Topkan Erkan, Arslan Gungor, Onal Cem, Oymak Ezgi, Yavuz Aydin
Format: Article
Language:English
Published: BMC 2009-07-01
Series:Journal of Experimental & Clinical Cancer Research
Online Access:http://www.jeccr.com/content/28/1/95
id doaj-f68f0d77c9fc48228c1d510b3fd771ec
record_format Article
spelling doaj-f68f0d77c9fc48228c1d510b3fd771ec2020-11-25T00:23:34ZengBMCJournal of Experimental & Clinical Cancer Research1756-99662009-07-012819510.1186/1756-9966-28-95Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk dosesYavuz MelekPehlivan BerrinTopkan ErkanArslan GungorOnal CemOymak EzgiYavuz Aydin<p>Abstract</p> <p>Background</p> <p>To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume analysis of organs at risk (OARs), by representing point doses defined by the International Commission on Radiation Units and Measurement (ICRU) and dose volume histograms (DVHs) from 3D planning.</p> <p>Methods</p> <p>We analyzed the dosimetric data for 62 conventional and CT-based ICBT plans. The gross tumor volume (GTV), clinical target volume (CTV) and organs at risk (OAR)s were contoured on the CT-plan. Point A and ICRU 38 rectal and bladder points were defined on reconstructed CT images.</p> <p>Results</p> <p>Patients were categorized on the basis of whether the >95% isodose line of the point-A prescription dose encompassed the CTV (group 1, n = 24) or not (group 2, n = 38). The mean GTV and CTV (8.1 cc and 20.6 cc) were smaller in group 1 than in group 2 (24.7 cc and 48.4 cc) (<it>P <</it>0.001). The mean percentage of GTV and CTV coverage with the 7 Gy isodose was 93.1% and 88.2% for all patients, and decreased with increasing tumor size and stage. The mean D2 and D5 rectum doses were 1.66 and 1.42 times higher than the corresponding ICRU point doses and the mean D2 and D5 bladder doses were 1.51 and 1.28 times higher. The differences between the ICRU dose and the D2 and D5 doses were significantly higher in group 2 than in group 1 for the bladder, but not for the rectum.</p> <p>Conclusion</p> <p>The CT-plan is superior to the conventional plan in target volume coverage and appropriate evaluation of OARs, as the conventional plan overestimates tumor doses and underestimates OAR doses.</p> http://www.jeccr.com/content/28/1/95
collection DOAJ
language English
format Article
sources DOAJ
author Yavuz Melek
Pehlivan Berrin
Topkan Erkan
Arslan Gungor
Onal Cem
Oymak Ezgi
Yavuz Aydin
spellingShingle Yavuz Melek
Pehlivan Berrin
Topkan Erkan
Arslan Gungor
Onal Cem
Oymak Ezgi
Yavuz Aydin
Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
Journal of Experimental & Clinical Cancer Research
author_facet Yavuz Melek
Pehlivan Berrin
Topkan Erkan
Arslan Gungor
Onal Cem
Oymak Ezgi
Yavuz Aydin
author_sort Yavuz Melek
title Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_short Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_full Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_fullStr Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_full_unstemmed Comparison of conventional and CT-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
title_sort comparison of conventional and ct-based planning for intracavitary brachytherapy for cervical cancer: target volume coverage and organs at risk doses
publisher BMC
series Journal of Experimental & Clinical Cancer Research
issn 1756-9966
publishDate 2009-07-01
description <p>Abstract</p> <p>Background</p> <p>To compare intracavitary brachytherapy (ICBT) planning methods for cervical cancer, based on either orthogonal radiographs (conventional plan) or CT sections (CT plan); the comparison focused on target volume coverage and dose volume analysis of organs at risk (OARs), by representing point doses defined by the International Commission on Radiation Units and Measurement (ICRU) and dose volume histograms (DVHs) from 3D planning.</p> <p>Methods</p> <p>We analyzed the dosimetric data for 62 conventional and CT-based ICBT plans. The gross tumor volume (GTV), clinical target volume (CTV) and organs at risk (OAR)s were contoured on the CT-plan. Point A and ICRU 38 rectal and bladder points were defined on reconstructed CT images.</p> <p>Results</p> <p>Patients were categorized on the basis of whether the >95% isodose line of the point-A prescription dose encompassed the CTV (group 1, n = 24) or not (group 2, n = 38). The mean GTV and CTV (8.1 cc and 20.6 cc) were smaller in group 1 than in group 2 (24.7 cc and 48.4 cc) (<it>P <</it>0.001). The mean percentage of GTV and CTV coverage with the 7 Gy isodose was 93.1% and 88.2% for all patients, and decreased with increasing tumor size and stage. The mean D2 and D5 rectum doses were 1.66 and 1.42 times higher than the corresponding ICRU point doses and the mean D2 and D5 bladder doses were 1.51 and 1.28 times higher. The differences between the ICRU dose and the D2 and D5 doses were significantly higher in group 2 than in group 1 for the bladder, but not for the rectum.</p> <p>Conclusion</p> <p>The CT-plan is superior to the conventional plan in target volume coverage and appropriate evaluation of OARs, as the conventional plan overestimates tumor doses and underestimates OAR doses.</p>
url http://www.jeccr.com/content/28/1/95
work_keys_str_mv AT yavuzmelek comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT pehlivanberrin comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT topkanerkan comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT arslangungor comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT onalcem comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT oymakezgi comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
AT yavuzaydin comparisonofconventionalandctbasedplanningforintracavitarybrachytherapyforcervicalcancertargetvolumecoverageandorgansatriskdoses
_version_ 1725356257658798080