Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantation

AIM:To systematically assess the efficacy and safety of femtosecond laser-assisted cataract surgery(FLACS)implanted with multifocal intraocular lens(MFIOL)with conventional cataract surgery. METHODS: Electronic databases of PubMed, EMbase, Cochrane and OVID were searched for studies comparing FLACS-...

Full description

Bibliographic Details
Main Authors: Hui-Min Ge, Wei-Ling Yan, Xiang-Zhong Xu, Qin Jiang
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2021-09-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2021/9/202109018.pdf
id doaj-f5d759b5e23747b1aca10b6816873cf6
record_format Article
spelling doaj-f5d759b5e23747b1aca10b6816873cf62021-08-18T13:41:13ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51232021-09-012191580158810.3980/j.issn.1672-5123.2021.9.18202109018Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantationHui-Min Ge0Wei-Ling Yan1Xiang-Zhong Xu2Qin Jiang3The Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210000, Jiangsu Province, ChinaThe Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210000, Jiangsu Province, ChinaThe Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210000, Jiangsu Province, ChinaThe Affiliated Eye Hospital of Nanjing Medical University, Nanjing 210000, Jiangsu Province, ChinaAIM:To systematically assess the efficacy and safety of femtosecond laser-assisted cataract surgery(FLACS)implanted with multifocal intraocular lens(MFIOL)with conventional cataract surgery. METHODS: Electronic databases of PubMed, EMbase, Cochrane and OVID were searched for studies comparing FLACS-MFIOL and CP-MFIOL. Two independent reviewers performed the data extraction and analyzed. Visual acuity, spherical equivalent(SE), pseudophakic accommodation, cumulative dissipated energy(CDE)and endothelial cell density(ECD)were measured by Review Manager 5.4. Sensitivity and reporting bias were determined through the STATA 14 software. RESULTS: From 106 screened articles, 1 045 eyes from 6 randomized controlled trials(RCTs)and 5 retrospective cohort studies were included(one of which contained two groups of comparative data). There was no evidence for any important differences in uncorrected distance visual acuity(UDVA)between FLACS-MFIOL and CP-MFIOL group after 1d, 1wk, 1, 3mo and 1a [s: -0.02, 95% Confidence Interval(CI)(-0.05, 0.01), P=0.13; s: -0.01, 95% CI(-0.03, 0.01), P=0.24; s: -0.03, 95% CI(-0.06, 0.00), P=0.05; s: -0.03, 95% CI(-0.14, 0.08), P=0.59; s: -0.03, 95% CI(-0.06, 0.00), P=0.10]. We found little evidence of any important difference in uncorrected near visual acuity(UNVA)between the two groups after 1d, 1wk, 3mo and 1a [s: 0.04, 95% CI(-0.04, 0.12), P=0.30; s: 0.04, 95% CI(-0.06, 0.13), P=0.47; s: 0.00, 95% CI(-0.04, 0.04), P=0.97; s: 0.03, 95% CI(-0.06, 0.12), P=0.54]. There was a small advantage in favor of FLACS-MFIOL over CP-MFIOL for UNVA after 1mo [s: 0.03, 95% CI(0.00, 0.06), P=0.04; s: 0.06, 95% CI(-0.02, 0.15), P=0.14]. In eyes treated with FLACS-MFIOL, SE showed no difference compared to CP-MFIOL [s: 0.06, 95% CI(-0.02, 0.15), P=0.14], however, better than CP-MFIOL in distance and near pseudophakic accommodation [s: 0.57, 95% CI(0.42, 0.72), P<0.001; s: 1.32, 95% CI(0.99, 1.64), P<0.001]. Smaller CDE [s: -1.94, 95% CI(-2.59, -1.30), P<0.01; s: -3.81, 95% CI(-5.66, -1.96), P<0.01] of Ⅱ and Ⅲ nucleus patients and increased ECD [s: 111.75, 95% CI(86.27, 137.23), P<0.01] in FLACS-MFIOL group were analyzed. The sensitivity analysis indicated that the results were robust and no obvious reporting bias. CONCLUSION: Compared to CP-MFIOL, FLACS-MFIOL makes a better visual quality and pseudophakic accommodation, as well as reducing endothelial cell loss and phacoemulsification energy.http://ies.ijo.cn/cn_publish/2021/9/202109018.pdffemtosecond laserphacoemulsificationmultifocal intraocular lensmeta-analysis
collection DOAJ
language English
format Article
sources DOAJ
author Hui-Min Ge
Wei-Ling Yan
Xiang-Zhong Xu
Qin Jiang
spellingShingle Hui-Min Ge
Wei-Ling Yan
Xiang-Zhong Xu
Qin Jiang
Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantation
Guoji Yanke Zazhi
femtosecond laser
phacoemulsification
multifocal intraocular lens
meta-analysis
author_facet Hui-Min Ge
Wei-Ling Yan
Xiang-Zhong Xu
Qin Jiang
author_sort Hui-Min Ge
title Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantation
title_short Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantation
title_full Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantation
title_fullStr Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantation
title_full_unstemmed Meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with MFIOL implantation
title_sort meta-analysis of the efficacy and safety of femtosecond laser-assisted phacoemulsification combined with mfiol implantation
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
publishDate 2021-09-01
description AIM:To systematically assess the efficacy and safety of femtosecond laser-assisted cataract surgery(FLACS)implanted with multifocal intraocular lens(MFIOL)with conventional cataract surgery. METHODS: Electronic databases of PubMed, EMbase, Cochrane and OVID were searched for studies comparing FLACS-MFIOL and CP-MFIOL. Two independent reviewers performed the data extraction and analyzed. Visual acuity, spherical equivalent(SE), pseudophakic accommodation, cumulative dissipated energy(CDE)and endothelial cell density(ECD)were measured by Review Manager 5.4. Sensitivity and reporting bias were determined through the STATA 14 software. RESULTS: From 106 screened articles, 1 045 eyes from 6 randomized controlled trials(RCTs)and 5 retrospective cohort studies were included(one of which contained two groups of comparative data). There was no evidence for any important differences in uncorrected distance visual acuity(UDVA)between FLACS-MFIOL and CP-MFIOL group after 1d, 1wk, 1, 3mo and 1a [s: -0.02, 95% Confidence Interval(CI)(-0.05, 0.01), P=0.13; s: -0.01, 95% CI(-0.03, 0.01), P=0.24; s: -0.03, 95% CI(-0.06, 0.00), P=0.05; s: -0.03, 95% CI(-0.14, 0.08), P=0.59; s: -0.03, 95% CI(-0.06, 0.00), P=0.10]. We found little evidence of any important difference in uncorrected near visual acuity(UNVA)between the two groups after 1d, 1wk, 3mo and 1a [s: 0.04, 95% CI(-0.04, 0.12), P=0.30; s: 0.04, 95% CI(-0.06, 0.13), P=0.47; s: 0.00, 95% CI(-0.04, 0.04), P=0.97; s: 0.03, 95% CI(-0.06, 0.12), P=0.54]. There was a small advantage in favor of FLACS-MFIOL over CP-MFIOL for UNVA after 1mo [s: 0.03, 95% CI(0.00, 0.06), P=0.04; s: 0.06, 95% CI(-0.02, 0.15), P=0.14]. In eyes treated with FLACS-MFIOL, SE showed no difference compared to CP-MFIOL [s: 0.06, 95% CI(-0.02, 0.15), P=0.14], however, better than CP-MFIOL in distance and near pseudophakic accommodation [s: 0.57, 95% CI(0.42, 0.72), P<0.001; s: 1.32, 95% CI(0.99, 1.64), P<0.001]. Smaller CDE [s: -1.94, 95% CI(-2.59, -1.30), P<0.01; s: -3.81, 95% CI(-5.66, -1.96), P<0.01] of Ⅱ and Ⅲ nucleus patients and increased ECD [s: 111.75, 95% CI(86.27, 137.23), P<0.01] in FLACS-MFIOL group were analyzed. The sensitivity analysis indicated that the results were robust and no obvious reporting bias. CONCLUSION: Compared to CP-MFIOL, FLACS-MFIOL makes a better visual quality and pseudophakic accommodation, as well as reducing endothelial cell loss and phacoemulsification energy.
topic femtosecond laser
phacoemulsification
multifocal intraocular lens
meta-analysis
url http://ies.ijo.cn/cn_publish/2021/9/202109018.pdf
work_keys_str_mv AT huiminge metaanalysisoftheefficacyandsafetyoffemtosecondlaserassistedphacoemulsificationcombinedwithmfiolimplantation
AT weilingyan metaanalysisoftheefficacyandsafetyoffemtosecondlaserassistedphacoemulsificationcombinedwithmfiolimplantation
AT xiangzhongxu metaanalysisoftheefficacyandsafetyoffemtosecondlaserassistedphacoemulsificationcombinedwithmfiolimplantation
AT qinjiang metaanalysisoftheefficacyandsafetyoffemtosecondlaserassistedphacoemulsificationcombinedwithmfiolimplantation
_version_ 1721202821699731456