Air exchange management in shipyard shops
At the present time a new design document “Ventilation and heating of shipyard shops” commissioned by the Department of shipbuilding industry, Ministry of Industry and Trade of Russian Federation, is being worked out. The second edition of the document was endorsed by the leading shipbuilders, desig...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Peter the Great St. Petersburg Polytechnic University
2013-10-01
|
Series: | Инженерно-строительный журнал |
Subjects: | |
Online Access: | http://engstroy.spb.ru/index_2013_06/grimitlin.pdf |
id |
doaj-f587a69faa1b4372b30bee0e6f8f1aa5 |
---|---|
record_format |
Article |
spelling |
doaj-f587a69faa1b4372b30bee0e6f8f1aa52020-11-25T01:50:54ZengPeter the Great St. Petersburg Polytechnic UniversityИнженерно-строительный журнал2071-47262071-03052013-10-0141671110.5862/MCE.41.1Air exchange management in shipyard shopsA.M. GrimitlinG.M. PozinAt the present time a new design document “Ventilation and heating of shipyard shops” commissioned by the Department of shipbuilding industry, Ministry of Industry and Trade of Russian Federation, is being worked out. The second edition of the document was endorsed by the leading shipbuilders, design and research organizations. Government confirmation of the document is planned on December 2013.The article describes the modern principles of air renewal in the shipyard shops, which will be used in the regulations that are being developed now.The mechanical ventilation should be provided in the shipyard shops. It is necessary to use local exhaust ventilation to collect harmful substances straight near the place of its dispersion. In addition to the local exhaust ventilation and also if it is impossible to organize it in given engineering process the general ventilation should be provided.http://engstroy.spb.ru/index_2013_06/grimitlin.pdfshipyard shopsventilationair supply methodsevaluation of air renewalmain types of local exhausts |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
A.M. Grimitlin G.M. Pozin |
spellingShingle |
A.M. Grimitlin G.M. Pozin Air exchange management in shipyard shops Инженерно-строительный журнал shipyard shops ventilation air supply methods evaluation of air renewal main types of local exhausts |
author_facet |
A.M. Grimitlin G.M. Pozin |
author_sort |
A.M. Grimitlin |
title |
Air exchange management in shipyard shops |
title_short |
Air exchange management in shipyard shops |
title_full |
Air exchange management in shipyard shops |
title_fullStr |
Air exchange management in shipyard shops |
title_full_unstemmed |
Air exchange management in shipyard shops |
title_sort |
air exchange management in shipyard shops |
publisher |
Peter the Great St. Petersburg Polytechnic University |
series |
Инженерно-строительный журнал |
issn |
2071-4726 2071-0305 |
publishDate |
2013-10-01 |
description |
At the present time a new design document “Ventilation and heating of shipyard shops” commissioned by the Department of shipbuilding industry, Ministry of Industry and Trade of Russian Federation, is being worked out. The second edition of the document was endorsed by the leading shipbuilders, design and research organizations. Government confirmation of the document is planned on December 2013.The article describes the modern principles of air renewal in the shipyard shops, which will be used in the regulations that are being developed now.The mechanical ventilation should be provided in the shipyard shops. It is necessary to use local exhaust ventilation to collect harmful substances straight near the place of its dispersion. In addition to the local exhaust ventilation and also if it is impossible to organize it in given engineering process the general ventilation should be provided. |
topic |
shipyard shops ventilation air supply methods evaluation of air renewal main types of local exhausts |
url |
http://engstroy.spb.ru/index_2013_06/grimitlin.pdf |