Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙ
In the nearest future, water consumption rate is to be reduced to 160 litres per person per day in Moscow. Water consumption reduction can cause reduction of the water flow velocity, deterioration of organoleptic properties of the water and cause flavours, odours, turbidity and colourity. The soluti...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Moscow State University of Civil Engineering (MGSU)
2013-04-01
|
Series: | Vestnik MGSU |
Subjects: | |
Online Access: | http://vestnikmgsu.ru/files/archive/RUS/issuepage/2013/4/13.pdf |
id |
doaj-f47e1dad98d64be4b2aeafbc259dd629 |
---|---|
record_format |
Article |
spelling |
doaj-f47e1dad98d64be4b2aeafbc259dd6292020-11-24T23:22:34ZengMoscow State University of Civil Engineering (MGSU)Vestnik MGSU 1997-09352304-66002013-04-014113120Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙOrlov Vladimir AleksandrovichAverkeev Il’ya AlekseevichIn the nearest future, water consumption rate is to be reduced to 160 litres per person per day in Moscow. Water consumption reduction can cause reduction of the water flow velocity, deterioration of organoleptic properties of the water and cause flavours, odours, turbidity and colourity. The solution may consist in the narrowing of the network diameter, especially in those sections that need urgent renovation, including trenchless renovation. It will accelerate the flow velocity and ensure pre-set sanitary and hygienic properties of the water. However, narrower diameters can affect fire water flows that constitute the subject matter of this research.The authors provide the research findings based on the automated hydraulic, technical and economic analysis of loop water supply systems performed through the employment of alternative renovation methods, modeling of a water supply network on the basis of existing diameters and on the basis of diameters reduced by grades 1 and 2. It is proven that water consumption reduction accompanied by the pipeline diameter reduction by one grade doesn’t cause deterioration of any hydraulic properties; rather, itaccelerates the water flow velocity and doesn’t cause any failure to comply with effective water supply norms applicable to fire extinguishing.The authors present their original method of identification of the optimal option for trenchless renovation of pipelines and their analysis of annual energy savings.<br>Представлены результаты исследований по проведению автоматизированных гидравлических и технико-экономических расчетов кольцевых водопроводных сетей с учетом альтернативных методов реновации, моделированию работы сети при реальных диаметрах, а также со сквозным их уменьшением на 1 и 2 сортамента. Показано, что в условиях снижения водопотребления уменьшение диаметра трубопроводных сетей на 1 сортамент не приводит к ухудшению гидравлических характеристик трубопроводов, способствует повышению скоростей течения воды и не влияет на обеспечение требуемых норм пожаротушения.Представлена методика определения оптимального варианта бестраншейной реновации трубопроводов и расчета годовой экономии электроэнергии.http://vestnikmgsu.ru/files/archive/RUS/issuepage/2013/4/13.pdfpipelineautomated designwater supply systemtrenchless renovationhydraulic modelfire extinguishing normsтрубопроводавтоматизированное проектированиеводопроводная сетьбестраншейная реновациягидравлическая модельнормы пожаротушения |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Orlov Vladimir Aleksandrovich Averkeev Il’ya Alekseevich |
spellingShingle |
Orlov Vladimir Aleksandrovich Averkeev Il’ya Alekseevich Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙ Vestnik MGSU pipeline automated design water supply system trenchless renovation hydraulic model fire extinguishing norms трубопровод автоматизированное проектирование водопроводная сеть бестраншейная реновация гидравлическая модель нормы пожаротушения |
author_facet |
Orlov Vladimir Aleksandrovich Averkeev Il’ya Alekseevich |
author_sort |
Orlov Vladimir Aleksandrovich |
title |
Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙ |
title_short |
Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙ |
title_full |
Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙ |
title_fullStr |
Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙ |
title_full_unstemmed |
Maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption ПОДДЕРЖАНИЕ ОПТИМАЛЬНЫХ ГИДРАВЛИЧЕСКИХ ПАРАМЕТРОВ РАБОТЫ ВОДОПРОВОДНЫХ СЕТЕЙ В УСЛОВИЯХ СОКРАЩЕННОГО ВОДОПОТРЕБЛЕНИЯ ПУТЕМ ИСПОЛЬЗОВАНИЯ БЕСТРАНШЕЙНЫХ ТЕХНОЛОГИЙ |
title_sort |
maintenance of optimum hydraulic parameters of operation of water supply networks using trenchless technologiesin the context of reduced water consumption поддержание оптимальных гидравлических параметров работы водопроводных сетей в условиях сокращенного водопотребления путем использования бестраншейных технологий |
publisher |
Moscow State University of Civil Engineering (MGSU) |
series |
Vestnik MGSU |
issn |
1997-0935 2304-6600 |
publishDate |
2013-04-01 |
description |
In the nearest future, water consumption rate is to be reduced to 160 litres per person per day in Moscow. Water consumption reduction can cause reduction of the water flow velocity, deterioration of organoleptic properties of the water and cause flavours, odours, turbidity and colourity. The solution may consist in the narrowing of the network diameter, especially in those sections that need urgent renovation, including trenchless renovation. It will accelerate the flow velocity and ensure pre-set sanitary and hygienic properties of the water. However, narrower diameters can affect fire water flows that constitute the subject matter of this research.The authors provide the research findings based on the automated hydraulic, technical and economic analysis of loop water supply systems performed through the employment of alternative renovation methods, modeling of a water supply network on the basis of existing diameters and on the basis of diameters reduced by grades 1 and 2. It is proven that water consumption reduction accompanied by the pipeline diameter reduction by one grade doesn’t cause deterioration of any hydraulic properties; rather, itaccelerates the water flow velocity and doesn’t cause any failure to comply with effective water supply norms applicable to fire extinguishing.The authors present their original method of identification of the optimal option for trenchless renovation of pipelines and their analysis of annual energy savings.<br>Представлены результаты исследований по проведению автоматизированных гидравлических и технико-экономических расчетов кольцевых водопроводных сетей с учетом альтернативных методов реновации, моделированию работы сети при реальных диаметрах, а также со сквозным их уменьшением на 1 и 2 сортамента. Показано, что в условиях снижения водопотребления уменьшение диаметра трубопроводных сетей на 1 сортамент не приводит к ухудшению гидравлических характеристик трубопроводов, способствует повышению скоростей течения воды и не влияет на обеспечение требуемых норм пожаротушения.Представлена методика определения оптимального варианта бестраншейной реновации трубопроводов и расчета годовой экономии электроэнергии. |
topic |
pipeline automated design water supply system trenchless renovation hydraulic model fire extinguishing norms трубопровод автоматизированное проектирование водопроводная сеть бестраншейная реновация гидравлическая модель нормы пожаротушения |
url |
http://vestnikmgsu.ru/files/archive/RUS/issuepage/2013/4/13.pdf |
work_keys_str_mv |
AT orlovvladimiraleksandrovich maintenanceofoptimumhydraulicparametersofoperationofwatersupplynetworksusingtrenchlesstechnologiesinthecontextofreducedwaterconsumptionpodderžanieoptimalʹnyhgidravličeskihparametrovrabotyvodoprovodnyhsetejvusloviâhsokraŝennogovodopotrebleniâputemisp AT averkeevilyaalekseevich maintenanceofoptimumhydraulicparametersofoperationofwatersupplynetworksusingtrenchlesstechnologiesinthecontextofreducedwaterconsumptionpodderžanieoptimalʹnyhgidravličeskihparametrovrabotyvodoprovodnyhsetejvusloviâhsokraŝennogovodopotrebleniâputemisp |
_version_ |
1725567538102796288 |