Comparative Study on Performance of Renewable Energy Building Energy Supply System
The air source heat pump water system test bench and the compact all-glass vacuum tube solar water heating system test bench are (were) built on the roof of two adjacent teacher’s apartment buildings with the same structure, shape and material were constructed to study the performance of energy supp...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2021-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/09/e3sconf_iaecst20_01077.pdf |
id |
doaj-f3d1062476b04c959276a329ea164ebb |
---|---|
record_format |
Article |
spelling |
doaj-f3d1062476b04c959276a329ea164ebb2021-02-01T08:05:44ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012330107710.1051/e3sconf/202123301077e3sconf_iaecst20_01077Comparative Study on Performance of Renewable Energy Building Energy Supply SystemXiufang Jiang0Rongdan Diao1Li Zeng2Ying Zhang3Xinrong Lei4College of Civil Engineering and Architecture, Wenzhou UniversityCollege of Civil Engineering and Architecture, Wenzhou UniversityWenZhou JianZheng Energy Technology Co., LtdCollege of Civil Engineering and Architecture, Wenzhou UniversityCollege of Civil Engineering and Architecture, Wenzhou UniversityThe air source heat pump water system test bench and the compact all-glass vacuum tube solar water heating system test bench are (were) built on the roof of two adjacent teacher’s apartment buildings with the same structure, shape and material were constructed to study the performance of energy supply systems for different types of renewable energy buildings. The energy supply system performance and the performance parameters are comprehensively and systematically analyzed in the same environment conditions of the same period. The results show that the weight coefficients of the performance parameters of the two energy supply systems are equal by means of extension theory analysis. At the last, the comprehensive correlation degree Kj(1) of water outlet temperature on the performance of renewable energy power supply system is 2.07, the comprehensive correlation degree Kj(2) of water inlet temperature is 2.04, the comprehensive correlation degree Kj(3) of air temperature is 2.14, the comprehensive correlation degree Kj(4) of solar radiation is 4.97, and the comprehensive correlation degree Kj(5) of sunshine hours is 3.78.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/09/e3sconf_iaecst20_01077.pdf |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Xiufang Jiang Rongdan Diao Li Zeng Ying Zhang Xinrong Lei |
spellingShingle |
Xiufang Jiang Rongdan Diao Li Zeng Ying Zhang Xinrong Lei Comparative Study on Performance of Renewable Energy Building Energy Supply System E3S Web of Conferences |
author_facet |
Xiufang Jiang Rongdan Diao Li Zeng Ying Zhang Xinrong Lei |
author_sort |
Xiufang Jiang |
title |
Comparative Study on Performance of Renewable Energy Building Energy Supply System |
title_short |
Comparative Study on Performance of Renewable Energy Building Energy Supply System |
title_full |
Comparative Study on Performance of Renewable Energy Building Energy Supply System |
title_fullStr |
Comparative Study on Performance of Renewable Energy Building Energy Supply System |
title_full_unstemmed |
Comparative Study on Performance of Renewable Energy Building Energy Supply System |
title_sort |
comparative study on performance of renewable energy building energy supply system |
publisher |
EDP Sciences |
series |
E3S Web of Conferences |
issn |
2267-1242 |
publishDate |
2021-01-01 |
description |
The air source heat pump water system test bench and the compact all-glass vacuum tube solar water heating system test bench are (were) built on the roof of two adjacent teacher’s apartment buildings with the same structure, shape and material were constructed to study the performance of energy supply systems for different types of renewable energy buildings. The energy supply system performance and the performance parameters are comprehensively and systematically analyzed in the same environment conditions of the same period. The results show that the weight coefficients of the performance parameters of the two energy supply systems are equal by means of extension theory analysis. At the last, the comprehensive correlation degree Kj(1) of water outlet temperature on the performance of renewable energy power supply system is 2.07, the comprehensive correlation degree Kj(2) of water inlet temperature is 2.04, the comprehensive correlation degree Kj(3) of air temperature is 2.14, the comprehensive correlation degree Kj(4) of solar radiation is 4.97, and the comprehensive correlation degree Kj(5) of sunshine hours is 3.78. |
url |
https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/09/e3sconf_iaecst20_01077.pdf |
work_keys_str_mv |
AT xiufangjiang comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem AT rongdandiao comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem AT lizeng comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem AT yingzhang comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem AT xinronglei comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem |
_version_ |
1724315711431507968 |