Comparative Study on Performance of Renewable Energy Building Energy Supply System

The air source heat pump water system test bench and the compact all-glass vacuum tube solar water heating system test bench are (were) built on the roof of two adjacent teacher’s apartment buildings with the same structure, shape and material were constructed to study the performance of energy supp...

Full description

Bibliographic Details
Main Authors: Xiufang Jiang, Rongdan Diao, Li Zeng, Ying Zhang, Xinrong Lei
Format: Article
Language:English
Published: EDP Sciences 2021-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/09/e3sconf_iaecst20_01077.pdf
id doaj-f3d1062476b04c959276a329ea164ebb
record_format Article
spelling doaj-f3d1062476b04c959276a329ea164ebb2021-02-01T08:05:44ZengEDP SciencesE3S Web of Conferences2267-12422021-01-012330107710.1051/e3sconf/202123301077e3sconf_iaecst20_01077Comparative Study on Performance of Renewable Energy Building Energy Supply SystemXiufang Jiang0Rongdan Diao1Li Zeng2Ying Zhang3Xinrong Lei4College of Civil Engineering and Architecture, Wenzhou UniversityCollege of Civil Engineering and Architecture, Wenzhou UniversityWenZhou JianZheng Energy Technology Co., LtdCollege of Civil Engineering and Architecture, Wenzhou UniversityCollege of Civil Engineering and Architecture, Wenzhou UniversityThe air source heat pump water system test bench and the compact all-glass vacuum tube solar water heating system test bench are (were) built on the roof of two adjacent teacher’s apartment buildings with the same structure, shape and material were constructed to study the performance of energy supply systems for different types of renewable energy buildings. The energy supply system performance and the performance parameters are comprehensively and systematically analyzed in the same environment conditions of the same period. The results show that the weight coefficients of the performance parameters of the two energy supply systems are equal by means of extension theory analysis. At the last, the comprehensive correlation degree Kj(1) of water outlet temperature on the performance of renewable energy power supply system is 2.07, the comprehensive correlation degree Kj(2) of water inlet temperature is 2.04, the comprehensive correlation degree Kj(3) of air temperature is 2.14, the comprehensive correlation degree Kj(4) of solar radiation is 4.97, and the comprehensive correlation degree Kj(5) of sunshine hours is 3.78.https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/09/e3sconf_iaecst20_01077.pdf
collection DOAJ
language English
format Article
sources DOAJ
author Xiufang Jiang
Rongdan Diao
Li Zeng
Ying Zhang
Xinrong Lei
spellingShingle Xiufang Jiang
Rongdan Diao
Li Zeng
Ying Zhang
Xinrong Lei
Comparative Study on Performance of Renewable Energy Building Energy Supply System
E3S Web of Conferences
author_facet Xiufang Jiang
Rongdan Diao
Li Zeng
Ying Zhang
Xinrong Lei
author_sort Xiufang Jiang
title Comparative Study on Performance of Renewable Energy Building Energy Supply System
title_short Comparative Study on Performance of Renewable Energy Building Energy Supply System
title_full Comparative Study on Performance of Renewable Energy Building Energy Supply System
title_fullStr Comparative Study on Performance of Renewable Energy Building Energy Supply System
title_full_unstemmed Comparative Study on Performance of Renewable Energy Building Energy Supply System
title_sort comparative study on performance of renewable energy building energy supply system
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2021-01-01
description The air source heat pump water system test bench and the compact all-glass vacuum tube solar water heating system test bench are (were) built on the roof of two adjacent teacher’s apartment buildings with the same structure, shape and material were constructed to study the performance of energy supply systems for different types of renewable energy buildings. The energy supply system performance and the performance parameters are comprehensively and systematically analyzed in the same environment conditions of the same period. The results show that the weight coefficients of the performance parameters of the two energy supply systems are equal by means of extension theory analysis. At the last, the comprehensive correlation degree Kj(1) of water outlet temperature on the performance of renewable energy power supply system is 2.07, the comprehensive correlation degree Kj(2) of water inlet temperature is 2.04, the comprehensive correlation degree Kj(3) of air temperature is 2.14, the comprehensive correlation degree Kj(4) of solar radiation is 4.97, and the comprehensive correlation degree Kj(5) of sunshine hours is 3.78.
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2021/09/e3sconf_iaecst20_01077.pdf
work_keys_str_mv AT xiufangjiang comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem
AT rongdandiao comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem
AT lizeng comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem
AT yingzhang comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem
AT xinronglei comparativestudyonperformanceofrenewableenergybuildingenergysupplysystem
_version_ 1724315711431507968