Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model

Hazard evaluation of engineered nanomaterials (ENMs) using real-world exposure scenario could provide better interpretation of toxicity end points for their use in the assessment of human safety and for their implications in many fields such as toxicology, nanomedicine, and so forth. However, most o...

Full description

Bibliographic Details
Main Authors: L. Di Cristo, B. Grimaldi, T. Catelani, E. Vázquez, P.P. Pompa, S. Sabella
Format: Article
Language:English
Published: Elsevier 2020-03-01
Series:Materials Today Bio
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2590006420300107
id doaj-f3b7f180c829422f88471217bff5f31f
record_format Article
spelling doaj-f3b7f180c829422f88471217bff5f31f2020-11-25T03:53:10ZengElsevierMaterials Today Bio2590-00642020-03-016100050Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway modelL. Di Cristo0B. Grimaldi1T. Catelani2E. Vázquez3P.P. Pompa4S. Sabella5Drug Discovery and Development Department, Istituto Italiano di Tecnologia, Via Morego 30, Genova, 16136, Italy; Corresponding author.Drug Discovery and Development Department, Istituto Italiano di Tecnologia, Via Morego 30, Genova, 16136, ItalyElectron Microscopy Facility, Istituto Italiano di Tecnologia, Via Morego 30, Genova, 16163, ItalyDepartamento de Química Orgánica, Facultad de Ciencias y Tecnologías Químicas-IRICA, Universidad de Castilla-La Mancha, Ciudad Real, 13071, SpainNanobiointeractions & Nanodiagnostics, Istituto Italiano di Tecnologia (IIT), Via Morego 30, Genova, 16163, ItalyDrug Discovery and Development Department, Istituto Italiano di Tecnologia, Via Morego 30, Genova, 16136, Italy; Corresponding author.Hazard evaluation of engineered nanomaterials (ENMs) using real-world exposure scenario could provide better interpretation of toxicity end points for their use in the assessment of human safety and for their implications in many fields such as toxicology, nanomedicine, and so forth. However, most of the current studies, both in vivo and in vitro, do not reflect realistic conditions of human exposure to ENMs, due to the high doses implemented. Moreover, the use of cellular models cultured under submerged conditions limits their physiological relevance for lung exposure, where cells are primarily cultured at the air-liquid interface. Addressing such issues is even more challenging for emergent nanomaterials, such as graphene oxide (GO), for which little or no information on exposure is available. In this work, we studied the impact of repeated exposure of GO on a three-dimensional (3D) reconstruct of human bronchial tissue, using a nebulizer system focusing on short-term effects. The selected doses (reaching a maximum of ca. 20 ​μg/cm2 for a period of 4 weeks of exposure) were extrapolated from alveolar mass deposition values of a broader class of carbon-based nanomaterials, reflecting a full working lifetime of human exposure. Experimental results did not show strong toxic effects of GO in terms of viability and integrity of the lung tissue. However, since 2 weeks of treatment, repeated GO exposure elicited a proinflammatory response, moderate barrier impairment, and autophagosome accumulation, a process resulting from blockade of autophagy flux. Interestingly, the 3D airway model could recover such an effect by restoring autophagy flux at longer exposure (30 days). These findings indicate that prolonged exposure to GO produces a time window (during the 30 days of treatment set for this study) for which GO-mediated autophagy inhibition along with inflammation may potentially increase the susceptibility of exposed humans to pulmonary infections and/or lung diseases. This study also highlights the importance of using physiologically relevant in vitro models and doses derived from real-world exposure to obtain focused data for the assessment of human safety.http://www.sciencedirect.com/science/article/pii/S25900064203001073D airway modelOccupational exposure limitsRepeated exposureAerosol systemWorking lifetime exposure
collection DOAJ
language English
format Article
sources DOAJ
author L. Di Cristo
B. Grimaldi
T. Catelani
E. Vázquez
P.P. Pompa
S. Sabella
spellingShingle L. Di Cristo
B. Grimaldi
T. Catelani
E. Vázquez
P.P. Pompa
S. Sabella
Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model
Materials Today Bio
3D airway model
Occupational exposure limits
Repeated exposure
Aerosol system
Working lifetime exposure
author_facet L. Di Cristo
B. Grimaldi
T. Catelani
E. Vázquez
P.P. Pompa
S. Sabella
author_sort L. Di Cristo
title Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model
title_short Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model
title_full Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model
title_fullStr Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model
title_full_unstemmed Repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model
title_sort repeated exposure to aerosolized graphene oxide mediates autophagy inhibition and inflammation in a three-dimensional human airway model
publisher Elsevier
series Materials Today Bio
issn 2590-0064
publishDate 2020-03-01
description Hazard evaluation of engineered nanomaterials (ENMs) using real-world exposure scenario could provide better interpretation of toxicity end points for their use in the assessment of human safety and for their implications in many fields such as toxicology, nanomedicine, and so forth. However, most of the current studies, both in vivo and in vitro, do not reflect realistic conditions of human exposure to ENMs, due to the high doses implemented. Moreover, the use of cellular models cultured under submerged conditions limits their physiological relevance for lung exposure, where cells are primarily cultured at the air-liquid interface. Addressing such issues is even more challenging for emergent nanomaterials, such as graphene oxide (GO), for which little or no information on exposure is available. In this work, we studied the impact of repeated exposure of GO on a three-dimensional (3D) reconstruct of human bronchial tissue, using a nebulizer system focusing on short-term effects. The selected doses (reaching a maximum of ca. 20 ​μg/cm2 for a period of 4 weeks of exposure) were extrapolated from alveolar mass deposition values of a broader class of carbon-based nanomaterials, reflecting a full working lifetime of human exposure. Experimental results did not show strong toxic effects of GO in terms of viability and integrity of the lung tissue. However, since 2 weeks of treatment, repeated GO exposure elicited a proinflammatory response, moderate barrier impairment, and autophagosome accumulation, a process resulting from blockade of autophagy flux. Interestingly, the 3D airway model could recover such an effect by restoring autophagy flux at longer exposure (30 days). These findings indicate that prolonged exposure to GO produces a time window (during the 30 days of treatment set for this study) for which GO-mediated autophagy inhibition along with inflammation may potentially increase the susceptibility of exposed humans to pulmonary infections and/or lung diseases. This study also highlights the importance of using physiologically relevant in vitro models and doses derived from real-world exposure to obtain focused data for the assessment of human safety.
topic 3D airway model
Occupational exposure limits
Repeated exposure
Aerosol system
Working lifetime exposure
url http://www.sciencedirect.com/science/article/pii/S2590006420300107
work_keys_str_mv AT ldicristo repeatedexposuretoaerosolizedgrapheneoxidemediatesautophagyinhibitionandinflammationinathreedimensionalhumanairwaymodel
AT bgrimaldi repeatedexposuretoaerosolizedgrapheneoxidemediatesautophagyinhibitionandinflammationinathreedimensionalhumanairwaymodel
AT tcatelani repeatedexposuretoaerosolizedgrapheneoxidemediatesautophagyinhibitionandinflammationinathreedimensionalhumanairwaymodel
AT evazquez repeatedexposuretoaerosolizedgrapheneoxidemediatesautophagyinhibitionandinflammationinathreedimensionalhumanairwaymodel
AT pppompa repeatedexposuretoaerosolizedgrapheneoxidemediatesautophagyinhibitionandinflammationinathreedimensionalhumanairwaymodel
AT ssabella repeatedexposuretoaerosolizedgrapheneoxidemediatesautophagyinhibitionandinflammationinathreedimensionalhumanairwaymodel
_version_ 1724479670838099968