Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, Cameroon

Background. The purpose of this study was to estimate the doses delivered to adult patients during chest examination for comparison with those elsewhere and to establish a local diagnostic reference level for the chest. The doses delivered in the standard X-ray examinations are not sufficiently opti...

Full description

Bibliographic Details
Main Authors: Guiswe Gnowe, Henri Paul Ekobena Fouda, Mbo Amvene Jéremie, Takmou Pascal, Bonaventure Babinne Graobe
Format: Article
Language:English
Published: Hindawi Limited 2019-01-01
Series:Radiology Research and Practice
Online Access:http://dx.doi.org/10.1155/2019/3619498
id doaj-f2c504646bd74c39a9c948f28882edbb
record_format Article
spelling doaj-f2c504646bd74c39a9c948f28882edbb2020-11-25T02:42:39ZengHindawi LimitedRadiology Research and Practice2090-19412090-195X2019-01-01201910.1155/2019/36194983619498Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, CameroonGuiswe Gnowe0Henri Paul Ekobena Fouda1Mbo Amvene Jéremie2Takmou Pascal3Bonaventure Babinne Graobe4Higher Institute of Sciences, Health Technics and Management of Garoua, Garoua, CameroonUniversity Technological of Institute, University of Ngaoundere, Ngaoundere, CameroonFaculty of Medicine and Biomedical Sciences of Garoua, Garoua, CameroonGeneral Hospital of Douala, Douala, CameroonHigher Institute of Sciences, Health Technics and Management of Garoua, Garoua, CameroonBackground. The purpose of this study was to estimate the doses delivered to adult patients during chest examination for comparison with those elsewhere and to establish a local diagnostic reference level for the chest. The doses delivered in the standard X-ray examinations are not sufficiently optimized and controlled. The working protocols for the same exam given differ for similar morphotypes within the same hospital structure. Materials and Methods. The entrance skin dose (mGy) of the chest was evaluated on 105 adult patients with a mass of 70 ± 10 kg in accordance with the 75th percentile of the irradiation parameters. The analysis and processing of the data was carried out by Excel 2010. The entrance skin dose of the chest obtained in mGy was 0.18 ± 0.21 for the PA incidence. Conclusion. The present study allowed us to observe large variations at the entrance skin doses of the chest. These variations have made it possible to understand that the entrance skin doses to the chest are optimized and do not exceed the proportions of those estimated by others and standards internationally. This aspect demonstrates that the diagnostic reference levels as enumerated are dependent on the doses delivered and include not only the notions of quality of the radiographic image and the quality assurance of the radiological equipments but also the level of the manipulators trained.http://dx.doi.org/10.1155/2019/3619498
collection DOAJ
language English
format Article
sources DOAJ
author Guiswe Gnowe
Henri Paul Ekobena Fouda
Mbo Amvene Jéremie
Takmou Pascal
Bonaventure Babinne Graobe
spellingShingle Guiswe Gnowe
Henri Paul Ekobena Fouda
Mbo Amvene Jéremie
Takmou Pascal
Bonaventure Babinne Graobe
Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, Cameroon
Radiology Research and Practice
author_facet Guiswe Gnowe
Henri Paul Ekobena Fouda
Mbo Amvene Jéremie
Takmou Pascal
Bonaventure Babinne Graobe
author_sort Guiswe Gnowe
title Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, Cameroon
title_short Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, Cameroon
title_full Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, Cameroon
title_fullStr Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, Cameroon
title_full_unstemmed Assessment of the Local Exposure Level during Adult Chest X-Rays at the Ngaoundere Regional Hospital, Cameroon
title_sort assessment of the local exposure level during adult chest x-rays at the ngaoundere regional hospital, cameroon
publisher Hindawi Limited
series Radiology Research and Practice
issn 2090-1941
2090-195X
publishDate 2019-01-01
description Background. The purpose of this study was to estimate the doses delivered to adult patients during chest examination for comparison with those elsewhere and to establish a local diagnostic reference level for the chest. The doses delivered in the standard X-ray examinations are not sufficiently optimized and controlled. The working protocols for the same exam given differ for similar morphotypes within the same hospital structure. Materials and Methods. The entrance skin dose (mGy) of the chest was evaluated on 105 adult patients with a mass of 70 ± 10 kg in accordance with the 75th percentile of the irradiation parameters. The analysis and processing of the data was carried out by Excel 2010. The entrance skin dose of the chest obtained in mGy was 0.18 ± 0.21 for the PA incidence. Conclusion. The present study allowed us to observe large variations at the entrance skin doses of the chest. These variations have made it possible to understand that the entrance skin doses to the chest are optimized and do not exceed the proportions of those estimated by others and standards internationally. This aspect demonstrates that the diagnostic reference levels as enumerated are dependent on the doses delivered and include not only the notions of quality of the radiographic image and the quality assurance of the radiological equipments but also the level of the manipulators trained.
url http://dx.doi.org/10.1155/2019/3619498
work_keys_str_mv AT guiswegnowe assessmentofthelocalexposurelevelduringadultchestxraysatthengaoundereregionalhospitalcameroon
AT henripaulekobenafouda assessmentofthelocalexposurelevelduringadultchestxraysatthengaoundereregionalhospitalcameroon
AT mboamvenejeremie assessmentofthelocalexposurelevelduringadultchestxraysatthengaoundereregionalhospitalcameroon
AT takmoupascal assessmentofthelocalexposurelevelduringadultchestxraysatthengaoundereregionalhospitalcameroon
AT bonaventurebabinnegraobe assessmentofthelocalexposurelevelduringadultchestxraysatthengaoundereregionalhospitalcameroon
_version_ 1724772391825965056