Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry Noise

An electromagnetic flowmeter (EMF) can be used to measure the speed of slurry fluid. In this paper, according to Maxwell's equations and the dB/dt vortex electric field, a step excitation scheme is proposed. The original excitation process of the primary excitation current rise time is divided...

Full description

Bibliographic Details
Main Authors: Bin Li, Yue Yan, Jie Chen, Xinghang Fan
Format: Article
Language:English
Published: IEEE 2020-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/9138428/
id doaj-f2bde15eb69141a4a50278dc91b3e5b8
record_format Article
spelling doaj-f2bde15eb69141a4a50278dc91b3e5b82021-03-30T02:08:38ZengIEEEIEEE Access2169-35362020-01-01812654012655810.1109/ACCESS.2020.30084199138428Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry NoiseBin Li0https://orcid.org/0000-0002-1381-8798Yue Yan1https://orcid.org/0000-0002-4904-0711Jie Chen2Xinghang Fan3https://orcid.org/0000-0002-2890-6141School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, ChinaSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai, ChinaSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai, ChinaSchool of Mechatronic Engineering and Automation, Shanghai University, Shanghai, ChinaAn electromagnetic flowmeter (EMF) can be used to measure the speed of slurry fluid. In this paper, according to Maxwell's equations and the dB/dt vortex electric field, a step excitation scheme is proposed. The original excitation process of the primary excitation current rise time is divided into a two-step excitation process. Without increasing the excitation current rise time, the equivalent excitation frequency is increased by increasing the primary dB/dt. This method can enhance the EMF's ability to overcome slurry noise. The paper analyzes the design parameters of the step excitation scheme and designs the software and hardware. After that, the paper compares the step excitation scheme with the three-value rectangular wave excitation scheme based on wavelet transform signal processing. Experiments show that the step excitation EMF has a lower steady-state fluctuation rate when measuring mortar and has a stronger ability to overcome slurry noise. Additionally, the step excitation EMF and Yokogawa AXF 040G EMF are compared experimentally. Through flow calibration, clean water measurement, mortar measurement and dynamic response experiment, it is verified that the step excitation EMF has the ability to enhance the resistance to slurry noise at the same excitation frequency.https://ieeexplore.ieee.org/document/9138428/Electromagnetic flowmeterslurry noiseMaxwell’s equationsstep excitationslurry noise overcoming method
collection DOAJ
language English
format Article
sources DOAJ
author Bin Li
Yue Yan
Jie Chen
Xinghang Fan
spellingShingle Bin Li
Yue Yan
Jie Chen
Xinghang Fan
Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry Noise
IEEE Access
Electromagnetic flowmeter
slurry noise
Maxwell’s equations
step excitation
slurry noise overcoming method
author_facet Bin Li
Yue Yan
Jie Chen
Xinghang Fan
author_sort Bin Li
title Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry Noise
title_short Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry Noise
title_full Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry Noise
title_fullStr Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry Noise
title_full_unstemmed Study of the Ability of an Electromagnetic Flowmeter Based on Step Excitation to Overcome Slurry Noise
title_sort study of the ability of an electromagnetic flowmeter based on step excitation to overcome slurry noise
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2020-01-01
description An electromagnetic flowmeter (EMF) can be used to measure the speed of slurry fluid. In this paper, according to Maxwell's equations and the dB/dt vortex electric field, a step excitation scheme is proposed. The original excitation process of the primary excitation current rise time is divided into a two-step excitation process. Without increasing the excitation current rise time, the equivalent excitation frequency is increased by increasing the primary dB/dt. This method can enhance the EMF's ability to overcome slurry noise. The paper analyzes the design parameters of the step excitation scheme and designs the software and hardware. After that, the paper compares the step excitation scheme with the three-value rectangular wave excitation scheme based on wavelet transform signal processing. Experiments show that the step excitation EMF has a lower steady-state fluctuation rate when measuring mortar and has a stronger ability to overcome slurry noise. Additionally, the step excitation EMF and Yokogawa AXF 040G EMF are compared experimentally. Through flow calibration, clean water measurement, mortar measurement and dynamic response experiment, it is verified that the step excitation EMF has the ability to enhance the resistance to slurry noise at the same excitation frequency.
topic Electromagnetic flowmeter
slurry noise
Maxwell’s equations
step excitation
slurry noise overcoming method
url https://ieeexplore.ieee.org/document/9138428/
work_keys_str_mv AT binli studyoftheabilityofanelectromagneticflowmeterbasedonstepexcitationtoovercomeslurrynoise
AT yueyan studyoftheabilityofanelectromagneticflowmeterbasedonstepexcitationtoovercomeslurrynoise
AT jiechen studyoftheabilityofanelectromagneticflowmeterbasedonstepexcitationtoovercomeslurrynoise
AT xinghangfan studyoftheabilityofanelectromagneticflowmeterbasedonstepexcitationtoovercomeslurrynoise
_version_ 1724185798773833728