What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography

<p>Abstract</p> <p>Background</p> <p>Insufficient data describe the relationship of hemodynamic parameters to left ventricular (LV) diastolic flow propagation velocity (Vp) measured using color M-mode Doppler echocardiography.</p> <p>Methods</p> <p&...

Full description

Bibliographic Details
Main Authors: Bess Renee L, Yoganathan Ajit P, Walker David K, Scotten Lawrence N, Ogawa Toshihiro, Nordstrom Cheryl K, Gardin Julius M
Format: Article
Language:English
Published: BMC 2005-09-01
Series:Cardiovascular Ultrasound
Online Access:http://www.cardiovascularultrasound.com/content/3/1/24
id doaj-f2addcbf7a3146f4b4540153055958a9
record_format Article
spelling doaj-f2addcbf7a3146f4b4540153055958a92020-11-25T00:07:27ZengBMCCardiovascular Ultrasound1476-71202005-09-01312410.1186/1476-7120-3-24What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiographyBess Renee LYoganathan Ajit PWalker David KScotten Lawrence NOgawa ToshihiroNordstrom Cheryl KGardin Julius M<p>Abstract</p> <p>Background</p> <p>Insufficient data describe the relationship of hemodynamic parameters to left ventricular (LV) diastolic flow propagation velocity (Vp) measured using color M-mode Doppler echocardiography.</p> <p>Methods</p> <p>An in vitro LV model used to simulate LV diastolic inflow with Vp measured under conditions of varying: 1) Stroke volume, 2) heart rate (HR), 3) LV volume, 4) LV compliance, and 5) transmitral flow (TMF) waveforms (Type 1: constant low diastasis flow and Type 2: no diastasis flow).</p> <p>Results</p> <p>Univariate analysis revealed excellent correlations of Vp with stroke volume (r = 0.98), LV compliance (r = 0.94), and HR with Type 1 TMF (r = 0.97). However, with Type 2 TMF, HR was not associated with Vp. LV volume was not related to Vp under low compliance, but inversely related to Vp under high compliance conditions (r = -0.56).</p> <p>Conclusion</p> <p>These in vitro findings may help elucidate the relationship of hemodynamic parameters to early diastolic LV filling.</p> http://www.cardiovascularultrasound.com/content/3/1/24
collection DOAJ
language English
format Article
sources DOAJ
author Bess Renee L
Yoganathan Ajit P
Walker David K
Scotten Lawrence N
Ogawa Toshihiro
Nordstrom Cheryl K
Gardin Julius M
spellingShingle Bess Renee L
Yoganathan Ajit P
Walker David K
Scotten Lawrence N
Ogawa Toshihiro
Nordstrom Cheryl K
Gardin Julius M
What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
Cardiovascular Ultrasound
author_facet Bess Renee L
Yoganathan Ajit P
Walker David K
Scotten Lawrence N
Ogawa Toshihiro
Nordstrom Cheryl K
Gardin Julius M
author_sort Bess Renee L
title What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
title_short What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
title_full What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
title_fullStr What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
title_full_unstemmed What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
title_sort what parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography
publisher BMC
series Cardiovascular Ultrasound
issn 1476-7120
publishDate 2005-09-01
description <p>Abstract</p> <p>Background</p> <p>Insufficient data describe the relationship of hemodynamic parameters to left ventricular (LV) diastolic flow propagation velocity (Vp) measured using color M-mode Doppler echocardiography.</p> <p>Methods</p> <p>An in vitro LV model used to simulate LV diastolic inflow with Vp measured under conditions of varying: 1) Stroke volume, 2) heart rate (HR), 3) LV volume, 4) LV compliance, and 5) transmitral flow (TMF) waveforms (Type 1: constant low diastasis flow and Type 2: no diastasis flow).</p> <p>Results</p> <p>Univariate analysis revealed excellent correlations of Vp with stroke volume (r = 0.98), LV compliance (r = 0.94), and HR with Type 1 TMF (r = 0.97). However, with Type 2 TMF, HR was not associated with Vp. LV volume was not related to Vp under low compliance, but inversely related to Vp under high compliance conditions (r = -0.56).</p> <p>Conclusion</p> <p>These in vitro findings may help elucidate the relationship of hemodynamic parameters to early diastolic LV filling.</p>
url http://www.cardiovascularultrasound.com/content/3/1/24
work_keys_str_mv AT bessreneel whatparametersaffectleftventriculardiastolicflowpropagationvelocityinvitrostudiesusingcolormmodedopplerechocardiography
AT yoganathanajitp whatparametersaffectleftventriculardiastolicflowpropagationvelocityinvitrostudiesusingcolormmodedopplerechocardiography
AT walkerdavidk whatparametersaffectleftventriculardiastolicflowpropagationvelocityinvitrostudiesusingcolormmodedopplerechocardiography
AT scottenlawrencen whatparametersaffectleftventriculardiastolicflowpropagationvelocityinvitrostudiesusingcolormmodedopplerechocardiography
AT ogawatoshihiro whatparametersaffectleftventriculardiastolicflowpropagationvelocityinvitrostudiesusingcolormmodedopplerechocardiography
AT nordstromcherylk whatparametersaffectleftventriculardiastolicflowpropagationvelocityinvitrostudiesusingcolormmodedopplerechocardiography
AT gardinjuliusm whatparametersaffectleftventriculardiastolicflowpropagationvelocityinvitrostudiesusingcolormmodedopplerechocardiography
_version_ 1725418051188293632