TLC-Densitometric Determination of Five Coxibs in Pharmaceutical Preparations
A class of drugs called coxibs (COX-2 inhibitors) were created to help relieve pain and inflammation of osteoarthritis and rheumatoid arthritis with the lowest amount of side effects possible. The presented paper describes a new developed, optimized and validated thin layer chromatographic (TLC)-den...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2020-05-01
|
Series: | Processes |
Subjects: | |
Online Access: | https://www.mdpi.com/2227-9717/8/5/620 |
id |
doaj-f29fc795476f48f9aac4d3c50a2227fd |
---|---|
record_format |
Article |
spelling |
doaj-f29fc795476f48f9aac4d3c50a2227fd2020-11-25T02:52:01ZengMDPI AGProcesses2227-97172020-05-01862062010.3390/pr8050620TLC-Densitometric Determination of Five Coxibs in Pharmaceutical PreparationsPaweł Gumułka0Monika Dąbrowska1Małgorzata Starek2Department of Inorganic and Analytical Chemistry, Faculty of Pharmacy, Jagiellonian University Medical College, 9 Medyczna St., 30-688 Kraków, PolandDepartment of Inorganic and Analytical Chemistry, Faculty of Pharmacy, Jagiellonian University Medical College, 9 Medyczna St., 30-688 Kraków, PolandDepartment of Inorganic and Analytical Chemistry, Faculty of Pharmacy, Jagiellonian University Medical College, 9 Medyczna St., 30-688 Kraków, PolandA class of drugs called coxibs (COX-2 inhibitors) were created to help relieve pain and inflammation of osteoarthritis and rheumatoid arthritis with the lowest amount of side effects possible. The presented paper describes a new developed, optimized and validated thin layer chromatographic (TLC)-densitometric procedure for the simultaneous assay of five coxibs: celecoxib, etoricoxib, firecoxib, rofecoxib and cimicoxib. Chromatographic separation was conducted on HPTLC F<sub>254</sub> silica gel chromatographic plates as a stationary phase using chloroform–acetone–toluene (12:5:2, <i>v</i>/<i>v</i>/<i>v</i>) as a mobile phase. Densitometric detection was carried out at two wavelengths of 254 and 290 nm. The method was tested according to ICH guidelines for linearity, recovery and specificity. The presented method was linear in a wide range of concentrations for all analyzed compounds, with correlation coefficients greater than 0.99. The method is specific, precise (%RSD < 1) and accurate (more than 95%, %RSD < 2). Low-cost, simple and rapid, it can be used in laboratories for drug monitoring and quality control.https://www.mdpi.com/2227-9717/8/5/620coxibsTLC-densitometryvalidation of the methodhuman and veterinary drugs |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Paweł Gumułka Monika Dąbrowska Małgorzata Starek |
spellingShingle |
Paweł Gumułka Monika Dąbrowska Małgorzata Starek TLC-Densitometric Determination of Five Coxibs in Pharmaceutical Preparations Processes coxibs TLC-densitometry validation of the method human and veterinary drugs |
author_facet |
Paweł Gumułka Monika Dąbrowska Małgorzata Starek |
author_sort |
Paweł Gumułka |
title |
TLC-Densitometric Determination of Five Coxibs in Pharmaceutical Preparations |
title_short |
TLC-Densitometric Determination of Five Coxibs in Pharmaceutical Preparations |
title_full |
TLC-Densitometric Determination of Five Coxibs in Pharmaceutical Preparations |
title_fullStr |
TLC-Densitometric Determination of Five Coxibs in Pharmaceutical Preparations |
title_full_unstemmed |
TLC-Densitometric Determination of Five Coxibs in Pharmaceutical Preparations |
title_sort |
tlc-densitometric determination of five coxibs in pharmaceutical preparations |
publisher |
MDPI AG |
series |
Processes |
issn |
2227-9717 |
publishDate |
2020-05-01 |
description |
A class of drugs called coxibs (COX-2 inhibitors) were created to help relieve pain and inflammation of osteoarthritis and rheumatoid arthritis with the lowest amount of side effects possible. The presented paper describes a new developed, optimized and validated thin layer chromatographic (TLC)-densitometric procedure for the simultaneous assay of five coxibs: celecoxib, etoricoxib, firecoxib, rofecoxib and cimicoxib. Chromatographic separation was conducted on HPTLC F<sub>254</sub> silica gel chromatographic plates as a stationary phase using chloroform–acetone–toluene (12:5:2, <i>v</i>/<i>v</i>/<i>v</i>) as a mobile phase. Densitometric detection was carried out at two wavelengths of 254 and 290 nm. The method was tested according to ICH guidelines for linearity, recovery and specificity. The presented method was linear in a wide range of concentrations for all analyzed compounds, with correlation coefficients greater than 0.99. The method is specific, precise (%RSD < 1) and accurate (more than 95%, %RSD < 2). Low-cost, simple and rapid, it can be used in laboratories for drug monitoring and quality control. |
topic |
coxibs TLC-densitometry validation of the method human and veterinary drugs |
url |
https://www.mdpi.com/2227-9717/8/5/620 |
work_keys_str_mv |
AT pawełgumułka tlcdensitometricdeterminationoffivecoxibsinpharmaceuticalpreparations AT monikadabrowska tlcdensitometricdeterminationoffivecoxibsinpharmaceuticalpreparations AT małgorzatastarek tlcdensitometricdeterminationoffivecoxibsinpharmaceuticalpreparations |
_version_ |
1724731939556950016 |