Active Filter Analysis on Designing Electronic Stethoscope

Early heart disease detection could be vital and some other diagnostic ways are being developed. In this paper, a lowcost tool for a diagnostic that analyzes the digitized heartbeat sound is given. This can be used to detect heart anomalies. The instrument shows the heart sound and also keeps a pati...

Full description

Bibliographic Details
Main Authors: Prihatin Oktivasari, Riandini Riandini, Rahmah A. Fitri, Sungguh I. Malaon
Format: Article
Language:English
Published: Indonesian Institute of Sciences 2019-12-01
Series:Jurnal Elektronika dan Telekomunikasi
Subjects:
Online Access:https://www.jurnalet.com/jet/article/view/278
id doaj-f1b513ace2514881a103ae7f5c9c536a
record_format Article
spelling doaj-f1b513ace2514881a103ae7f5c9c536a2020-11-25T02:39:59ZengIndonesian Institute of SciencesJurnal Elektronika dan Telekomunikasi1411-82892527-99552019-12-01192515610.14203/jet.v19.51-56163Active Filter Analysis on Designing Electronic StethoscopePrihatin Oktivasari0Riandini Riandini1Rahmah A. Fitri2Sungguh I. Malaon3Department of Informatic and Computer Engineering -Politeknik Negeri JakartaDepartment of Electrical Engineering - Politeknik Negeri JakartaDepartment of Electrical Engineering - Politeknik Negeri JakartaDepartment of Electrical Engineering - Politeknik Negeri JakartaEarly heart disease detection could be vital and some other diagnostic ways are being developed. In this paper, a lowcost tool for a diagnostic that analyzes the digitized heartbeat sound is given. This can be used to detect heart anomalies. The instrument shows the heart sound and also keeps a patient's long-term record for future use. The signal from the heart provides a lot of knowledge about the heart and offers an initial diagnosis recommendation. The electronic stethoscope uses the condenser microphone, preamplifier circuit, and filter circuit. The optimum filter is Butterworth with a fourth-order Sallen key low pass filter topology with a gain of 0.707 volts, -3.01 dB, and a fourth-order high pass filter with a gain of 0.782 volts, -2.137 dB. The frequency of the heart sound is about 20 Hz – 120 Hz in general. Therefore, the lower cutoff frequency of the filter is set to 20 Hz, while the higher cutoff frequency set to 120 Hz. The evaluation used to measure the performance of an electronic stethoscope is to compare with a conventional stethoscope, the recorded sound is the same.https://www.jurnalet.com/jet/article/view/278filteramplifiercondenser micelectronic stethoscope
collection DOAJ
language English
format Article
sources DOAJ
author Prihatin Oktivasari
Riandini Riandini
Rahmah A. Fitri
Sungguh I. Malaon
spellingShingle Prihatin Oktivasari
Riandini Riandini
Rahmah A. Fitri
Sungguh I. Malaon
Active Filter Analysis on Designing Electronic Stethoscope
Jurnal Elektronika dan Telekomunikasi
filter
amplifier
condenser mic
electronic stethoscope
author_facet Prihatin Oktivasari
Riandini Riandini
Rahmah A. Fitri
Sungguh I. Malaon
author_sort Prihatin Oktivasari
title Active Filter Analysis on Designing Electronic Stethoscope
title_short Active Filter Analysis on Designing Electronic Stethoscope
title_full Active Filter Analysis on Designing Electronic Stethoscope
title_fullStr Active Filter Analysis on Designing Electronic Stethoscope
title_full_unstemmed Active Filter Analysis on Designing Electronic Stethoscope
title_sort active filter analysis on designing electronic stethoscope
publisher Indonesian Institute of Sciences
series Jurnal Elektronika dan Telekomunikasi
issn 1411-8289
2527-9955
publishDate 2019-12-01
description Early heart disease detection could be vital and some other diagnostic ways are being developed. In this paper, a lowcost tool for a diagnostic that analyzes the digitized heartbeat sound is given. This can be used to detect heart anomalies. The instrument shows the heart sound and also keeps a patient's long-term record for future use. The signal from the heart provides a lot of knowledge about the heart and offers an initial diagnosis recommendation. The electronic stethoscope uses the condenser microphone, preamplifier circuit, and filter circuit. The optimum filter is Butterworth with a fourth-order Sallen key low pass filter topology with a gain of 0.707 volts, -3.01 dB, and a fourth-order high pass filter with a gain of 0.782 volts, -2.137 dB. The frequency of the heart sound is about 20 Hz – 120 Hz in general. Therefore, the lower cutoff frequency of the filter is set to 20 Hz, while the higher cutoff frequency set to 120 Hz. The evaluation used to measure the performance of an electronic stethoscope is to compare with a conventional stethoscope, the recorded sound is the same.
topic filter
amplifier
condenser mic
electronic stethoscope
url https://www.jurnalet.com/jet/article/view/278
work_keys_str_mv AT prihatinoktivasari activefilteranalysisondesigningelectronicstethoscope
AT riandiniriandini activefilteranalysisondesigningelectronicstethoscope
AT rahmahafitri activefilteranalysisondesigningelectronicstethoscope
AT sungguhimalaon activefilteranalysisondesigningelectronicstethoscope
_version_ 1724783740123611136