Comparison of different configurations of the solar and wind power supply system with energy storage using Matlab

In the study the hybrid model of the solar and wind power supply system with electrochemical energy storage developed in MATLAB & SIMULINK and MS Visual Studio environments was presented. Simulation tests of the system with rated power of 60 kW were conducted in different configurations of conne...

Full description

Bibliographic Details
Main Authors: Głuchy Damian, Jarmuda Tomasz, Tomczewski Andrzej
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:ITM Web of Conferences
Online Access:https://doi.org/10.1051/itmconf/20181901023
Description
Summary:In the study the hybrid model of the solar and wind power supply system with electrochemical energy storage developed in MATLAB & SIMULINK and MS Visual Studio environments was presented. Simulation tests of the system with rated power of 60 kW were conducted in different configurations of connections with the receiver with the set load characteristics. For each configuration of the system the length of periods with no power supply of the receiver was calculated along with the value of the energy consumed and given to the power grid in the case of application of the electrochemical storage and its lack.