Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
Abstract In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted insid...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Al-Khwarizmi College of Engineering – University of Baghdad
2015-06-01
|
Series: | Al-Khawarizmi Engineering Journal |
Subjects: | |
Online Access: | http://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/252 |
id |
doaj-f1a647001563492d9dda18267184c5e8 |
---|---|
record_format |
Article |
spelling |
doaj-f1a647001563492d9dda18267184c5e82020-11-24T21:55:29Zeng Al-Khwarizmi College of Engineering – University of BaghdadAl-Khawarizmi Engineering Journal1818-11712312-07892015-06-01113Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar CollectorJafar M. Hassan0Qussai J. Abdul-Ghafour1Mohammed F. Mohammed2Department of Mechanical Engineering/ University of TechnologyDepartment of Mechanical Engineering/ University of TechnologyDepartment of Mechanical Engineering/ University of Technology Abstract In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150) ℓ /hr. were 49 %, 57% and 63% respectively. Keywords: Twisted strip, solar collectors. http://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/252Keywords: Twisted strip, solar collectors. |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jafar M. Hassan Qussai J. Abdul-Ghafour Mohammed F. Mohammed |
spellingShingle |
Jafar M. Hassan Qussai J. Abdul-Ghafour Mohammed F. Mohammed Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector Al-Khawarizmi Engineering Journal Keywords: Twisted strip, solar collectors. |
author_facet |
Jafar M. Hassan Qussai J. Abdul-Ghafour Mohammed F. Mohammed |
author_sort |
Jafar M. Hassan |
title |
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector |
title_short |
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector |
title_full |
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector |
title_fullStr |
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector |
title_full_unstemmed |
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector |
title_sort |
influences of the twisted strips insertion on the performance of flat plate water solar collector |
publisher |
Al-Khwarizmi College of Engineering – University of Baghdad |
series |
Al-Khawarizmi Engineering Journal |
issn |
1818-1171 2312-0789 |
publishDate |
2015-06-01 |
description |
Abstract
In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150) ℓ /hr. were 49 %, 57% and 63% respectively.
Keywords: Twisted strip, solar collectors.
|
topic |
Keywords: Twisted strip, solar collectors. |
url |
http://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/252 |
work_keys_str_mv |
AT jafarmhassan influencesofthetwistedstripsinsertionontheperformanceofflatplatewatersolarcollector AT qussaijabdulghafour influencesofthetwistedstripsinsertionontheperformanceofflatplatewatersolarcollector AT mohammedfmohammed influencesofthetwistedstripsinsertionontheperformanceofflatplatewatersolarcollector |
_version_ |
1725862342545113088 |