Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector

Abstract     In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted insid...

Full description

Bibliographic Details
Main Authors: Jafar M. Hassan, Qussai J. Abdul-Ghafour, Mohammed F. Mohammed
Format: Article
Language:English
Published: Al-Khwarizmi College of Engineering – University of Baghdad 2015-06-01
Series:Al-Khawarizmi Engineering Journal
Subjects:
Online Access:http://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/252
id doaj-f1a647001563492d9dda18267184c5e8
record_format Article
spelling doaj-f1a647001563492d9dda18267184c5e82020-11-24T21:55:29Zeng Al-Khwarizmi College of Engineering – University of BaghdadAl-Khawarizmi Engineering Journal1818-11712312-07892015-06-01113Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar CollectorJafar M. Hassan0Qussai J. Abdul-Ghafour1Mohammed F. Mohammed2Department of Mechanical Engineering/ University of TechnologyDepartment of Mechanical Engineering/ University of TechnologyDepartment of Mechanical Engineering/ University of Technology Abstract     In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150) ℓ /hr. were 49 %, 57% and 63% respectively.  Keywords: Twisted strip, solar collectors. http://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/252Keywords: Twisted strip, solar collectors.
collection DOAJ
language English
format Article
sources DOAJ
author Jafar M. Hassan
Qussai J. Abdul-Ghafour
Mohammed F. Mohammed
spellingShingle Jafar M. Hassan
Qussai J. Abdul-Ghafour
Mohammed F. Mohammed
Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
Al-Khawarizmi Engineering Journal
Keywords: Twisted strip, solar collectors.
author_facet Jafar M. Hassan
Qussai J. Abdul-Ghafour
Mohammed F. Mohammed
author_sort Jafar M. Hassan
title Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
title_short Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
title_full Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
title_fullStr Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
title_full_unstemmed Influences of the Twisted Strips Insertion on the Performance of Flat Plate Water Solar Collector
title_sort influences of the twisted strips insertion on the performance of flat plate water solar collector
publisher Al-Khwarizmi College of Engineering – University of Baghdad
series Al-Khawarizmi Engineering Journal
issn 1818-1171
2312-0789
publishDate 2015-06-01
description Abstract     In order to enhance the efficiency of flat plate solar water collectors without changing in its original shape and with low additional cost, twisted strips are inserted inside its riser pipes. Three flat plate collectors are used for test. Family of twisted strips are inserted inside each collector risers with different twisted ratios (TR=3,4,5). The collectors are connected in parallel mode (Z-Configuration) and are exposed to the same conditions (solar radiation and ambient temperature) .The experimental results show that, the highest heat transfer rate occurs at twisted ratio (3) .Consequently, for the same twisted ratio the daily efficiencies for the solar collector at different flow rate used (60,100 and 150) ℓ /hr. were 49 %, 57% and 63% respectively.  Keywords: Twisted strip, solar collectors.
topic Keywords: Twisted strip, solar collectors.
url http://alkej.uobaghdad.edu.iq/index.php/alkej/article/view/252
work_keys_str_mv AT jafarmhassan influencesofthetwistedstripsinsertionontheperformanceofflatplatewatersolarcollector
AT qussaijabdulghafour influencesofthetwistedstripsinsertionontheperformanceofflatplatewatersolarcollector
AT mohammedfmohammed influencesofthetwistedstripsinsertionontheperformanceofflatplatewatersolarcollector
_version_ 1725862342545113088