Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum

<p>This article describes a differential pulse voltammetric (DPV) method for the determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electro-oxidation of diclofenac at platinum electrode in 0.1 M TBAClO<sub>4</sub>/acetonitri...

Full description

Bibliographic Details
Main Authors: Bilal Yilmaz, Selcuk Kaban, Bilge Kagan Akcay, Ulvihan Ciltas
Format: Article
Language:English
Published: Universidade de São Paulo 2015-06-01
Series:Brazilian Journal of Pharmaceutical Sciences
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502015000200285&lng=en&tlng=en
id doaj-f1a61ef90aeb453da892ec6f7dfb3627
record_format Article
spelling doaj-f1a61ef90aeb453da892ec6f7dfb36272020-11-25T00:33:35ZengUniversidade de São PauloBrazilian Journal of Pharmaceutical Sciences2175-97902015-06-0151228529410.1590/S1984-82502015000200005S1984-82502015000200285Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serumBilal YilmazSelcuk KabanBilge Kagan AkcayUlvihan Ciltas<p>This article describes a differential pulse voltammetric (DPV) method for the determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electro-oxidation of diclofenac at platinum electrode in 0.1 M TBAClO<sub>4</sub>/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL<sup>-1</sup>and 2-20 μg mL<sup>-1</sup> in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.87, and accuracy (relative error) was better than 4.12%. The method developed in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. In addition, the proposed technique was successfully applied to spiked human serum samples. No electro-active interferences from the endogenous substances were found in human serum.</p>http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502015000200285&lng=en&tlng=enDiclofenaco/determinaçãoVoltametria de pulso diferencial/análise quantitativaFormulações farmacêuticas/análiseSoro humano/análise.
collection DOAJ
language English
format Article
sources DOAJ
author Bilal Yilmaz
Selcuk Kaban
Bilge Kagan Akcay
Ulvihan Ciltas
spellingShingle Bilal Yilmaz
Selcuk Kaban
Bilge Kagan Akcay
Ulvihan Ciltas
Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
Brazilian Journal of Pharmaceutical Sciences
Diclofenaco/determinação
Voltametria de pulso diferencial/análise quantitativa
Formulações farmacêuticas/análise
Soro humano/análise.
author_facet Bilal Yilmaz
Selcuk Kaban
Bilge Kagan Akcay
Ulvihan Ciltas
author_sort Bilal Yilmaz
title Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
title_short Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
title_full Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
title_fullStr Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
title_full_unstemmed Differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
title_sort differential pulse voltammetric determination of diclofenac in pharmaceutical preparations and human serum
publisher Universidade de São Paulo
series Brazilian Journal of Pharmaceutical Sciences
issn 2175-9790
publishDate 2015-06-01
description <p>This article describes a differential pulse voltammetric (DPV) method for the determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electro-oxidation of diclofenac at platinum electrode in 0.1 M TBAClO<sub>4</sub>/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL<sup>-1</sup>and 2-20 μg mL<sup>-1</sup> in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.87, and accuracy (relative error) was better than 4.12%. The method developed in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. In addition, the proposed technique was successfully applied to spiked human serum samples. No electro-active interferences from the endogenous substances were found in human serum.</p>
topic Diclofenaco/determinação
Voltametria de pulso diferencial/análise quantitativa
Formulações farmacêuticas/análise
Soro humano/análise.
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502015000200285&lng=en&tlng=en
work_keys_str_mv AT bilalyilmaz differentialpulsevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
AT selcukkaban differentialpulsevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
AT bilgekaganakcay differentialpulsevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
AT ulvihanciltas differentialpulsevoltammetricdeterminationofdiclofenacinpharmaceuticalpreparationsandhumanserum
_version_ 1725316095034785792