PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN
The influence of feed ratios ((LE/LR) ) on the performance of a packed liquid-liquid extraction column, with a diameter of 5.86 cm and a column height of 132 cm was investigated. The column is made of borosilicate glass and packed with 10 x 10 mm glass Raschig rings. In this study, a ternary system...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Pamukkale University
1999-03-01
|
Series: | Pamukkale University Journal of Engineering Sciences |
Subjects: | |
Online Access: | http://dergipark.ulakbim.gov.tr/pajes/article/view/5000089978 |
id |
doaj-f19eddf0d9324b98abaaefc4d5498d38 |
---|---|
record_format |
Article |
spelling |
doaj-f19eddf0d9324b98abaaefc4d5498d382020-11-24T22:29:03ZengPamukkale UniversityPamukkale University Journal of Engineering Sciences1300-70092147-58811999-03-0153116311675000084046PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMNİ. Metin HASDEMİRMehmet BİLGİNAhmet AYDINUmur DRAMURThe influence of feed ratios ((LE/LR) ) on the performance of a packed liquid-liquid extraction column, with a diameter of 5.86 cm and a column height of 132 cm was investigated. The column is made of borosilicate glass and packed with 10 x 10 mm glass Raschig rings. In this study, a ternary system composed of water + propionic acid + trichloroethylene was used. The data used to triangular diagram were obtained experimentally. The overall mass transfer coefficients, the numbers of overall mass transfer units, the heights of mass transfer units, the numbers of theoretical stages and height equivalent to a theoretical stage (H. E. T. S.) values were calculated and compared with each other.http://dergipark.ulakbim.gov.tr/pajes/article/view/5000089978Ekstraksiyon, Sıvı-sıvı, Dolgulu kolon, Kütle transferi |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
İ. Metin HASDEMİR Mehmet BİLGİN Ahmet AYDIN Umur DRAMUR |
spellingShingle |
İ. Metin HASDEMİR Mehmet BİLGİN Ahmet AYDIN Umur DRAMUR PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN Pamukkale University Journal of Engineering Sciences Ekstraksiyon, Sıvı-sıvı, Dolgulu kolon, Kütle transferi |
author_facet |
İ. Metin HASDEMİR Mehmet BİLGİN Ahmet AYDIN Umur DRAMUR |
author_sort |
İ. Metin HASDEMİR |
title |
PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN |
title_short |
PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN |
title_full |
PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN |
title_fullStr |
PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN |
title_full_unstemmed |
PERFORMANCE OF A PACKED LIQUID-LIQUID EXTRACTION COLUMN |
title_sort |
performance of a packed liquid-liquid extraction column |
publisher |
Pamukkale University |
series |
Pamukkale University Journal of Engineering Sciences |
issn |
1300-7009 2147-5881 |
publishDate |
1999-03-01 |
description |
The influence of feed ratios ((LE/LR) ) on the performance of a packed liquid-liquid extraction column, with a diameter of 5.86 cm and a column height of 132 cm was investigated. The column is made of borosilicate glass and packed with 10 x 10 mm glass Raschig rings. In this study, a ternary system composed of water + propionic acid + trichloroethylene was used. The data used to triangular diagram were obtained experimentally. The overall mass transfer coefficients, the numbers of overall mass transfer units, the heights of mass transfer units, the numbers of theoretical stages and height equivalent to a theoretical stage (H. E. T. S.) values were calculated and compared with each other. |
topic |
Ekstraksiyon, Sıvı-sıvı, Dolgulu kolon, Kütle transferi |
url |
http://dergipark.ulakbim.gov.tr/pajes/article/view/5000089978 |
work_keys_str_mv |
AT imetinhasdemir performanceofapackedliquidliquidextractioncolumn AT mehmetbilgin performanceofapackedliquidliquidextractioncolumn AT ahmetaydin performanceofapackedliquidliquidextractioncolumn AT umurdramur performanceofapackedliquidliquidextractioncolumn |
_version_ |
1725745050200047616 |