Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers

OBJETIVO: O objetivo deste trabalho é estudar, em peças anatômicas; a relação entre os parafusos bicorticais pela técnica de Harms e Melcher e a artéria carótida interna. MÉTODOS: Nossa amostra consiste em cinco cadáveres. RESULTADOS: Os resultados encontrados foram: a média da menor distância entre...

Full description

Bibliographic Details
Main Authors: Guilherme Zanini Rocha, Aluízio Augusto Arantes Junior, Cassius Vinicius Correa dos Reis, Sebastião Nataniel Silva Gusmão, Warley Martins, Arthur Adolfo Nicolato, Guilherme Lourenço Lima Reis, Fernando Flavio Vasconcelos Gonçalves, Julio César Boynard Santiago
Format: Article
Language:English
Published: Sociedade Brasileira de Coluna (SBC) 2011-01-01
Series:Coluna/Columna
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512011000100011
id doaj-f158f1f57bfa409ea80e67f152f9aaeb
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Guilherme Zanini Rocha
Aluízio Augusto Arantes Junior
Cassius Vinicius Correa dos Reis
Sebastião Nataniel Silva Gusmão
Warley Martins
Arthur Adolfo Nicolato
Guilherme Lourenço Lima Reis
Fernando Flavio Vasconcelos Gonçalves
Julio César Boynard Santiago
spellingShingle Guilherme Zanini Rocha
Aluízio Augusto Arantes Junior
Cassius Vinicius Correa dos Reis
Sebastião Nataniel Silva Gusmão
Warley Martins
Arthur Adolfo Nicolato
Guilherme Lourenço Lima Reis
Fernando Flavio Vasconcelos Gonçalves
Julio César Boynard Santiago
Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
Coluna/Columna
Columna vertebral
Atlas cervical
Tornillos óseos
Arteria carótida interna
Cadáver
Tomografía
Coluna vertebral
Atlas cervical
Parafusos ósseos
Artéria carótida interna
Cadáver
Tomografia
Spine
Cervical atlas
bone screws
Carotid artery, internal
Cadaver
Tomography
author_facet Guilherme Zanini Rocha
Aluízio Augusto Arantes Junior
Cassius Vinicius Correa dos Reis
Sebastião Nataniel Silva Gusmão
Warley Martins
Arthur Adolfo Nicolato
Guilherme Lourenço Lima Reis
Fernando Flavio Vasconcelos Gonçalves
Julio César Boynard Santiago
author_sort Guilherme Zanini Rocha
title Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
title_short Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
title_full Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
title_fullStr Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
title_full_unstemmed Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
title_sort avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadavers
publisher Sociedade Brasileira de Coluna (SBC)
series Coluna/Columna
issn 1808-1851
2177-014X
publishDate 2011-01-01
description OBJETIVO: O objetivo deste trabalho é estudar, em peças anatômicas; a relação entre os parafusos bicorticais pela técnica de Harms e Melcher e a artéria carótida interna. MÉTODOS: Nossa amostra consiste em cinco cadáveres. RESULTADOS: Os resultados encontrados foram: a média da menor distância entre o orifício de saída do parafuso e a borda medial da artéria carótida interna direita foi de 11,55 mm (com variação de 10,05 a 14,23 mm), enquanto do lado esquerdo a média foi de 7,50 mm (variando de 2,75 a 12,42 mm). A média da menor distância entre a borda posterior da artéria carótida interna e a cortical anterior da massa lateral de C1 à direita foi de 4,24 mm (variando de 2,08 a 7,48 mm), enquanto do lado esquerdo a média obtida foi de 2,98 mm (com variação de 1,83 a 3,83 mm). CONCLUSÃO: Os resultados encontrados estão de acordo com os estudos similares existentes na literatura que enfatizam a necessidade de uma avaliação imaginológica criteriosa da posição anatômica da artéria carótida interna antes da utilização de parafusos bicorticais na massa lateral de C1 por via posterior.<br>OBJETIVO: O objetivo de este estudio es, en las piezas anatómicas, la relación entre los tornillos bicorticales, mediante la técnica de Harms y Melcher, y la arteria carótida interna. MÉTODOS: La muestra se compone de cinco cadáveres. RESULTADOS: Los resultados fueron: la distancia más corta promedio, entre la salida del tornillo y el borde medial de la arteria carótida interna derecha, fue 11,55 mm (rango de 10,05 a 14,23 mm), mientras que, en la izquierda, el promedio fue 7,50 mm (rango 2,75 a 12,42 mm). La distancia más corta promedio, entre el borde posterior de la arteria carótida interna y la cortical anterior C1 de la derecha, fue 4,24 mm (que van desde 2,08 hasta 7,48 mm), mientras que, en el lado izquierdo, el promedio fue 2,98 mm. (que van desde 1,83 hasta 3,83 mm). Conclusión: Los resultados son consistentes con estudios similares en la literatura que hacen hincapié en la necesidad de una evaluación cuidadosa de las imágenes y posición anatómica de la arteria carótida interna, antes del uso de tornillos bicorticales de masa lateral de C1 por acceso posterior.<br>OBJECTIVE: The objective of this study is to study the relationship between bicortical screws and the internal carotid artery, in anatomical body parts, in screw fixation by the Harms and Melcher technique. METHODS: Our sample consisted of five cadavers. RESULTS: The results were as follows: the average shortest distance between the outlet of the screw and the medial edge of the right internal carotid artery was 11.55 mm (range 10.05 to 14.23 mm), while on the left side, the average was 7.50 mm (ranging from 2.75 to 12.42 mm). The average shortest distance between the posterior edge of the internal carotid artery and the anterior cortical C1 lateral mass on the right was 4.24 mm (ranging from 2.08 to 7.48 mm), while the left side, the average was 2.98 mm (ranging from 1.83 to 3.83 mm). CONCLUSION: The results are consistent with similar studies in the literature that emphasize the need for a careful assessment of images of anatomical position of the internal carotid artery prior to the use of bicortical screws in the C1 lateral mass by posterior access.
topic Columna vertebral
Atlas cervical
Tornillos óseos
Arteria carótida interna
Cadáver
Tomografía
Coluna vertebral
Atlas cervical
Parafusos ósseos
Artéria carótida interna
Cadáver
Tomografia
Spine
Cervical atlas
bone screws
Carotid artery, internal
Cadaver
Tomography
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512011000100011
work_keys_str_mv AT guilhermezaninirocha avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT aluizioaugustoarantesjunior avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT cassiusviniciuscorreadosreis avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT sebastiaonatanielsilvagusmao avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT warleymartins avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT arthuradolfonicolato avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT guilhermelourencolimareis avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT fernandoflaviovasconcelosgoncalves avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
AT juliocesarboynardsantiago avaliacaodatrajetoriadosparafusosbicorticaispelatecnicadeharmsemelcheremrelacaoaarteriacarotidainternaestudoexperimentalemcadaveresevaluaciondelatrayectoriadelostornillosbicorticalesenlatecnicadeharmsymelcherenrelacionconlaarteriacarotidainternaunestudioe
_version_ 1725981818581155840
spelling doaj-f158f1f57bfa409ea80e67f152f9aaeb2020-11-24T21:25:56ZengSociedade Brasileira de Coluna (SBC)Coluna/Columna 1808-18512177-014X2011-01-01101586110.1590/S1808-18512011000100011Avaliação da trajetória dos parafusos bicorticais pela técnica de harms e melcher em relação à artéria carótida interna: estudo experimental em cadáveres Evaluación de la trayectoria de los tornillos bicorticales en la técnica de harms y melcher en relación con la arteria carótida interna: un estudio experimental en cadáveres Evaluation of the trajectory of the bicortical screws in relation to the internal carotid artery, in fixation by the harms and melcher technique: an experimental study in cadaversGuilherme Zanini RochaAluízio Augusto Arantes JuniorCassius Vinicius Correa dos ReisSebastião Nataniel Silva GusmãoWarley MartinsArthur Adolfo NicolatoGuilherme Lourenço Lima ReisFernando Flavio Vasconcelos GonçalvesJulio César Boynard SantiagoOBJETIVO: O objetivo deste trabalho é estudar, em peças anatômicas; a relação entre os parafusos bicorticais pela técnica de Harms e Melcher e a artéria carótida interna. MÉTODOS: Nossa amostra consiste em cinco cadáveres. RESULTADOS: Os resultados encontrados foram: a média da menor distância entre o orifício de saída do parafuso e a borda medial da artéria carótida interna direita foi de 11,55 mm (com variação de 10,05 a 14,23 mm), enquanto do lado esquerdo a média foi de 7,50 mm (variando de 2,75 a 12,42 mm). A média da menor distância entre a borda posterior da artéria carótida interna e a cortical anterior da massa lateral de C1 à direita foi de 4,24 mm (variando de 2,08 a 7,48 mm), enquanto do lado esquerdo a média obtida foi de 2,98 mm (com variação de 1,83 a 3,83 mm). CONCLUSÃO: Os resultados encontrados estão de acordo com os estudos similares existentes na literatura que enfatizam a necessidade de uma avaliação imaginológica criteriosa da posição anatômica da artéria carótida interna antes da utilização de parafusos bicorticais na massa lateral de C1 por via posterior.<br>OBJETIVO: O objetivo de este estudio es, en las piezas anatómicas, la relación entre los tornillos bicorticales, mediante la técnica de Harms y Melcher, y la arteria carótida interna. MÉTODOS: La muestra se compone de cinco cadáveres. RESULTADOS: Los resultados fueron: la distancia más corta promedio, entre la salida del tornillo y el borde medial de la arteria carótida interna derecha, fue 11,55 mm (rango de 10,05 a 14,23 mm), mientras que, en la izquierda, el promedio fue 7,50 mm (rango 2,75 a 12,42 mm). La distancia más corta promedio, entre el borde posterior de la arteria carótida interna y la cortical anterior C1 de la derecha, fue 4,24 mm (que van desde 2,08 hasta 7,48 mm), mientras que, en el lado izquierdo, el promedio fue 2,98 mm. (que van desde 1,83 hasta 3,83 mm). Conclusión: Los resultados son consistentes con estudios similares en la literatura que hacen hincapié en la necesidad de una evaluación cuidadosa de las imágenes y posición anatómica de la arteria carótida interna, antes del uso de tornillos bicorticales de masa lateral de C1 por acceso posterior.<br>OBJECTIVE: The objective of this study is to study the relationship between bicortical screws and the internal carotid artery, in anatomical body parts, in screw fixation by the Harms and Melcher technique. METHODS: Our sample consisted of five cadavers. RESULTS: The results were as follows: the average shortest distance between the outlet of the screw and the medial edge of the right internal carotid artery was 11.55 mm (range 10.05 to 14.23 mm), while on the left side, the average was 7.50 mm (ranging from 2.75 to 12.42 mm). The average shortest distance between the posterior edge of the internal carotid artery and the anterior cortical C1 lateral mass on the right was 4.24 mm (ranging from 2.08 to 7.48 mm), while the left side, the average was 2.98 mm (ranging from 1.83 to 3.83 mm). CONCLUSION: The results are consistent with similar studies in the literature that emphasize the need for a careful assessment of images of anatomical position of the internal carotid artery prior to the use of bicortical screws in the C1 lateral mass by posterior access.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-18512011000100011Columna vertebralAtlas cervicalTornillos óseosArteria carótida internaCadáverTomografíaColuna vertebralAtlas cervicalParafusos ósseosArtéria carótida internaCadáverTomografiaSpineCervical atlasbone screwsCarotid artery, internalCadaverTomography