A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded

Background. Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim. The aim of this study was to compare early changes of stability for two implants with identical macrodesign but with different surface topographies. Materials and Methods....

Full description

Bibliographic Details
Main Authors: Leonardo Vanden Bogaerde, Lars Sennerby
Format: Article
Language:English
Published: Hindawi Limited 2016-01-01
Series:International Journal of Dentistry
Online Access:http://dx.doi.org/10.1155/2016/8424931
id doaj-f0cd96d7bfd84dd7b70291aa15b36b45
record_format Article
spelling doaj-f0cd96d7bfd84dd7b70291aa15b36b452020-11-25T01:11:45ZengHindawi LimitedInternational Journal of Dentistry1687-87281687-87362016-01-01201610.1155/2016/84249318424931A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately LoadedLeonardo Vanden Bogaerde0Lars Sennerby1Private Practice, Via Dante Alighieri 32, 20049 Concorezzo, ItalyDepartment of Oral & Maxillofacial Surgery, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Medicinaregatan 12C, P.O. Box 450, 405 30 Gothenburg, SwedenBackground. Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim. The aim of this study was to compare early changes of stability for two implants with identical macrodesign but with different surface topographies. Materials and Methods. In 11 patients, a total of 22 implants (11 bimodal (minimally rough, control) and 11 proactive (moderately rough and hydrophilic, test), Neoss Ltd., Harrogate, UK) were immediately placed into fresh extraction sockets and immediately loaded. The peak insertion torque (IT) was measured in Ncm at placement. Resonance Frequency Analysis (RFA) measurements were made at baseline and 2, 4, 6, and 12 weeks after surgery. Results. The two implant types showed similar IT and RFA values at placement (NS). A dip of RFA values after 2 weeks followed by an increase was observed, where the test implant showed a less pronounced decrease and a more rapid recovery than the control implant. The test implants were significantly more stable than the control ones after 12 weeks. Conclusions. The results from the present study indicated that the hydrophilic and rougher test implant was more resistant to immediate loading and showed a significantly higher stability than the smoother control implant after 12 weeks.http://dx.doi.org/10.1155/2016/8424931
collection DOAJ
language English
format Article
sources DOAJ
author Leonardo Vanden Bogaerde
Lars Sennerby
spellingShingle Leonardo Vanden Bogaerde
Lars Sennerby
A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
International Journal of Dentistry
author_facet Leonardo Vanden Bogaerde
Lars Sennerby
author_sort Leonardo Vanden Bogaerde
title A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
title_short A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
title_full A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
title_fullStr A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
title_full_unstemmed A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
title_sort randomized case-series study comparing the stability of implant with two different surfaces placed in fresh extraction sockets and immediately loaded
publisher Hindawi Limited
series International Journal of Dentistry
issn 1687-8728
1687-8736
publishDate 2016-01-01
description Background. Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim. The aim of this study was to compare early changes of stability for two implants with identical macrodesign but with different surface topographies. Materials and Methods. In 11 patients, a total of 22 implants (11 bimodal (minimally rough, control) and 11 proactive (moderately rough and hydrophilic, test), Neoss Ltd., Harrogate, UK) were immediately placed into fresh extraction sockets and immediately loaded. The peak insertion torque (IT) was measured in Ncm at placement. Resonance Frequency Analysis (RFA) measurements were made at baseline and 2, 4, 6, and 12 weeks after surgery. Results. The two implant types showed similar IT and RFA values at placement (NS). A dip of RFA values after 2 weeks followed by an increase was observed, where the test implant showed a less pronounced decrease and a more rapid recovery than the control implant. The test implants were significantly more stable than the control ones after 12 weeks. Conclusions. The results from the present study indicated that the hydrophilic and rougher test implant was more resistant to immediate loading and showed a significantly higher stability than the smoother control implant after 12 weeks.
url http://dx.doi.org/10.1155/2016/8424931
work_keys_str_mv AT leonardovandenbogaerde arandomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded
AT larssennerby arandomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded
AT leonardovandenbogaerde randomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded
AT larssennerby randomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded
_version_ 1725169873270603776