A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
Background. Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim. The aim of this study was to compare early changes of stability for two implants with identical macrodesign but with different surface topographies. Materials and Methods....
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2016-01-01
|
Series: | International Journal of Dentistry |
Online Access: | http://dx.doi.org/10.1155/2016/8424931 |
id |
doaj-f0cd96d7bfd84dd7b70291aa15b36b45 |
---|---|
record_format |
Article |
spelling |
doaj-f0cd96d7bfd84dd7b70291aa15b36b452020-11-25T01:11:45ZengHindawi LimitedInternational Journal of Dentistry1687-87281687-87362016-01-01201610.1155/2016/84249318424931A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately LoadedLeonardo Vanden Bogaerde0Lars Sennerby1Private Practice, Via Dante Alighieri 32, 20049 Concorezzo, ItalyDepartment of Oral & Maxillofacial Surgery, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, Medicinaregatan 12C, P.O. Box 450, 405 30 Gothenburg, SwedenBackground. Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim. The aim of this study was to compare early changes of stability for two implants with identical macrodesign but with different surface topographies. Materials and Methods. In 11 patients, a total of 22 implants (11 bimodal (minimally rough, control) and 11 proactive (moderately rough and hydrophilic, test), Neoss Ltd., Harrogate, UK) were immediately placed into fresh extraction sockets and immediately loaded. The peak insertion torque (IT) was measured in Ncm at placement. Resonance Frequency Analysis (RFA) measurements were made at baseline and 2, 4, 6, and 12 weeks after surgery. Results. The two implant types showed similar IT and RFA values at placement (NS). A dip of RFA values after 2 weeks followed by an increase was observed, where the test implant showed a less pronounced decrease and a more rapid recovery than the control implant. The test implants were significantly more stable than the control ones after 12 weeks. Conclusions. The results from the present study indicated that the hydrophilic and rougher test implant was more resistant to immediate loading and showed a significantly higher stability than the smoother control implant after 12 weeks.http://dx.doi.org/10.1155/2016/8424931 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Leonardo Vanden Bogaerde Lars Sennerby |
spellingShingle |
Leonardo Vanden Bogaerde Lars Sennerby A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded International Journal of Dentistry |
author_facet |
Leonardo Vanden Bogaerde Lars Sennerby |
author_sort |
Leonardo Vanden Bogaerde |
title |
A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded |
title_short |
A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded |
title_full |
A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded |
title_fullStr |
A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded |
title_full_unstemmed |
A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded |
title_sort |
randomized case-series study comparing the stability of implant with two different surfaces placed in fresh extraction sockets and immediately loaded |
publisher |
Hindawi Limited |
series |
International Journal of Dentistry |
issn |
1687-8728 1687-8736 |
publishDate |
2016-01-01 |
description |
Background. Hydrophilic and moderately rough implant surfaces have been proposed to enhance the osseointegration response. Aim. The aim of this study was to compare early changes of stability for two implants with identical macrodesign but with different surface topographies. Materials and Methods. In 11 patients, a total of 22 implants (11 bimodal (minimally rough, control) and 11 proactive (moderately rough and hydrophilic, test), Neoss Ltd., Harrogate, UK) were immediately placed into fresh extraction sockets and immediately loaded. The peak insertion torque (IT) was measured in Ncm at placement. Resonance Frequency Analysis (RFA) measurements were made at baseline and 2, 4, 6, and 12 weeks after surgery. Results. The two implant types showed similar IT and RFA values at placement (NS). A dip of RFA values after 2 weeks followed by an increase was observed, where the test implant showed a less pronounced decrease and a more rapid recovery than the control implant. The test implants were significantly more stable than the control ones after 12 weeks. Conclusions. The results from the present study indicated that the hydrophilic and rougher test implant was more resistant to immediate loading and showed a significantly higher stability than the smoother control implant after 12 weeks. |
url |
http://dx.doi.org/10.1155/2016/8424931 |
work_keys_str_mv |
AT leonardovandenbogaerde arandomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded AT larssennerby arandomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded AT leonardovandenbogaerde randomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded AT larssennerby randomizedcaseseriesstudycomparingthestabilityofimplantwithtwodifferentsurfacesplacedinfreshextractionsocketsandimmediatelyloaded |
_version_ |
1725169873270603776 |