The Device for Low-Cost Measurement of 2D Thermal Distribution
<span style="font-family: Times New Roman; font-size: small;"> </span><p class="Abstract" style="margin: 1pt 0in 0pt;"><span lang="EN-US"><span style="font-size: x-small;"><span style="font-family: Times New Roma...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
International Science and Engineering Society, o.s.
2012-12-01
|
Series: | International Journal of Advances in Telecommunications, Electrotechnics, Signals and Systems |
Online Access: | http://ijates.org/index.php/ijates/article/view/38 |
id |
doaj-f08f45d202114d7f85bf207821e3b441 |
---|---|
record_format |
Article |
spelling |
doaj-f08f45d202114d7f85bf207821e3b4412020-11-25T00:03:25ZengInternational Science and Engineering Society, o.s.International Journal of Advances in Telecommunications, Electrotechnics, Signals and Systems1805-54432012-12-0112-3495210.11601/ijates.v1i2-3.3829The Device for Low-Cost Measurement of 2D Thermal DistributionJiri Minar0Kamil Riha1Brno University of TechnologyBrno University of Technology<span style="font-family: Times New Roman; font-size: small;"> </span><p class="Abstract" style="margin: 1pt 0in 0pt;"><span lang="EN-US"><span style="font-size: x-small;"><span style="font-family: Times New Roman;">The article describes a specialized device for measurement of thermal distribution of two dimensional surfaces for some applications in medical industry, and mechanical or civil engineering. The device is a substitution of expensive device for this kind of measurement is thermal camera which can be expensive for some application or should have the limitation of non-possibility to read temperature behind a barrier (wall, bandage). </span></span></span></p><span style="font-family: Times New Roman; font-size: small;"> </span><p class="Abstract" style="margin: 1pt 0in 0pt;"><span lang="EN-US"><span style="font-size: x-small;"><span style="font-family: Times New Roman;">The main goal of this work was to design a device for measurement of thermal distribution on 2D surface for low-cost measuring processes with slow change of temperature and for processes, which do not require high resolution of collected data. The next advantage of presented device is a possibility of temperature measurement behind the barrier.</span></span></span></p><span style="font-family: Times New Roman; font-size: small;"> </span>http://ijates.org/index.php/ijates/article/view/38 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jiri Minar Kamil Riha |
spellingShingle |
Jiri Minar Kamil Riha The Device for Low-Cost Measurement of 2D Thermal Distribution International Journal of Advances in Telecommunications, Electrotechnics, Signals and Systems |
author_facet |
Jiri Minar Kamil Riha |
author_sort |
Jiri Minar |
title |
The Device for Low-Cost Measurement of 2D Thermal Distribution |
title_short |
The Device for Low-Cost Measurement of 2D Thermal Distribution |
title_full |
The Device for Low-Cost Measurement of 2D Thermal Distribution |
title_fullStr |
The Device for Low-Cost Measurement of 2D Thermal Distribution |
title_full_unstemmed |
The Device for Low-Cost Measurement of 2D Thermal Distribution |
title_sort |
device for low-cost measurement of 2d thermal distribution |
publisher |
International Science and Engineering Society, o.s. |
series |
International Journal of Advances in Telecommunications, Electrotechnics, Signals and Systems |
issn |
1805-5443 |
publishDate |
2012-12-01 |
description |
<span style="font-family: Times New Roman; font-size: small;"> </span><p class="Abstract" style="margin: 1pt 0in 0pt;"><span lang="EN-US"><span style="font-size: x-small;"><span style="font-family: Times New Roman;">The article describes a specialized device for measurement of thermal distribution of two dimensional surfaces for some applications in medical industry, and mechanical or civil engineering. The device is a substitution of expensive device for this kind of measurement is thermal camera which can be expensive for some application or should have the limitation of non-possibility to read temperature behind a barrier (wall, bandage). </span></span></span></p><span style="font-family: Times New Roman; font-size: small;"> </span><p class="Abstract" style="margin: 1pt 0in 0pt;"><span lang="EN-US"><span style="font-size: x-small;"><span style="font-family: Times New Roman;">The main goal of this work was to design a device for measurement of thermal distribution on 2D surface for low-cost measuring processes with slow change of temperature and for processes, which do not require high resolution of collected data. The next advantage of presented device is a possibility of temperature measurement behind the barrier.</span></span></span></p><span style="font-family: Times New Roman; font-size: small;"> </span> |
url |
http://ijates.org/index.php/ijates/article/view/38 |
work_keys_str_mv |
AT jiriminar thedeviceforlowcostmeasurementof2dthermaldistribution AT kamilriha thedeviceforlowcostmeasurementof2dthermaldistribution AT jiriminar deviceforlowcostmeasurementof2dthermaldistribution AT kamilriha deviceforlowcostmeasurementof2dthermaldistribution |
_version_ |
1725434043708735488 |