Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone

The essence of the research was to develop a correlation dependence between the degree of limestone grinding and the efficiency of boiler flue gas desulfurization. The design of the Installation of Flue Gas Desulfurization (FGD) in the slurry of ground limestone begins with the assumption (based on...

Full description

Bibliographic Details
Main Author: Romanik Elżbieta
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20184400152
id doaj-f08cbaf979464cde931343d903fcfc37
record_format Article
spelling doaj-f08cbaf979464cde931343d903fcfc372021-02-02T05:45:44ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01440015210.1051/e3sconf/20184400152e3sconf_eko-dok2018_00152Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestoneRomanik ElżbietaThe essence of the research was to develop a correlation dependence between the degree of limestone grinding and the efficiency of boiler flue gas desulfurization. The design of the Installation of Flue Gas Desulfurization (FGD) in the slurry of ground limestone begins with the assumption (based on literature data or experience gained from previously completed and operated installations) of a certain pH value of this slurry in the reactor tank. The reagent is not yet indicated, its extraction location, its chemical composition, grain size and reactivity are not determined. Application practice and economics of these processes have shown that calcium reagents are the most advantageous in application because of the general availability of limestone, its large mining resources, existing infrastructure for its extraction, the network of suppliers and the purchase cost acceptable by the recipients. On a global scale, more than 90% of the flue gas desulfurization plant is treated with limestone [1]. The effectiveness of the desulfurization process is high, and some believe that the decisive influence is on the degree of limestone fragmentation dissolution rate of CaCO3 in the absorption slurry, its reactivity to absorbed SO2, the pH of the absorption slurry.https://doi.org/10.1051/e3sconf/20184400152
collection DOAJ
language English
format Article
sources DOAJ
author Romanik Elżbieta
spellingShingle Romanik Elżbieta
Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone
E3S Web of Conferences
author_facet Romanik Elżbieta
author_sort Romanik Elżbieta
title Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone
title_short Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone
title_full Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone
title_fullStr Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone
title_full_unstemmed Examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone
title_sort examination of the influence of macro and microscopic parameters of limestone on the effectiveness of gas phase desulphurisation according to the method of wet limestone
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2018-01-01
description The essence of the research was to develop a correlation dependence between the degree of limestone grinding and the efficiency of boiler flue gas desulfurization. The design of the Installation of Flue Gas Desulfurization (FGD) in the slurry of ground limestone begins with the assumption (based on literature data or experience gained from previously completed and operated installations) of a certain pH value of this slurry in the reactor tank. The reagent is not yet indicated, its extraction location, its chemical composition, grain size and reactivity are not determined. Application practice and economics of these processes have shown that calcium reagents are the most advantageous in application because of the general availability of limestone, its large mining resources, existing infrastructure for its extraction, the network of suppliers and the purchase cost acceptable by the recipients. On a global scale, more than 90% of the flue gas desulfurization plant is treated with limestone [1]. The effectiveness of the desulfurization process is high, and some believe that the decisive influence is on the degree of limestone fragmentation dissolution rate of CaCO3 in the absorption slurry, its reactivity to absorbed SO2, the pH of the absorption slurry.
url https://doi.org/10.1051/e3sconf/20184400152
work_keys_str_mv AT romanikelzbieta examinationoftheinfluenceofmacroandmicroscopicparametersoflimestoneontheeffectivenessofgasphasedesulphurisationaccordingtothemethodofwetlimestone
_version_ 1724302884876582912