INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION
In addition to other detonation parameters detonation velocity is a value that provides indirect information on the strength i.e. brisance of an explosive and explosive performance. In addition to that, detonation velocity is a value which can be measured in a relatively simpler and more precise man...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Mining, Geology and Petroleum Engineering
2014-12-01
|
Series: | Rudarsko-geološko-naftni Zbornik |
Subjects: | |
Online Access: | http://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=199051&lang=en |
id |
doaj-f04437d4479042258b1da07318556766 |
---|---|
record_format |
Article |
spelling |
doaj-f04437d4479042258b1da073185567662020-11-24T21:56:39ZengFaculty of Mining, Geology and Petroleum EngineeringRudarsko-geološko-naftni Zbornik0353-45291849-04092014-12-012914955INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATIONMario Dobrilović0Vječislav Bohanek1Vinko Škrlec2Faculty of Mining, Geology and Petroleum Engineering, University of Zagreb, Pierottijeva 6, Zagreb, CroatiaFaculty of Mining, Geology and Petroleum Engineering, University of Zagreb, Pierottijeva 6, Zagreb, CroatiaFaculty of Mining, Geology and Petroleum Engineering, University of Zagreb, Pierottijeva 6, Zagreb, CroatiaIn addition to other detonation parameters detonation velocity is a value that provides indirect information on the strength i.e. brisance of an explosive and explosive performance. In addition to that, detonation velocity is a value which can be measured in a relatively simpler and more precise manner, by developed and accessible methods when compared to other detonation parameters Due to its simple use, compact instruments and satisfactory accuracy, electro-optical method of detonation velocity measurement is widely used. The paper describes the electro-optical measurement method and points out the factors that affect its accuracy. The accuracy of measurement is increased and measurement uncertainty is reduced by the measurement result analysis with the application of different measurement setups.http://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=199051&lang=envelocity of detonationelectro-optical methodmeasurement uncertainty |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Mario Dobrilović Vječislav Bohanek Vinko Škrlec |
spellingShingle |
Mario Dobrilović Vječislav Bohanek Vinko Škrlec INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION Rudarsko-geološko-naftni Zbornik velocity of detonation electro-optical method measurement uncertainty |
author_facet |
Mario Dobrilović Vječislav Bohanek Vinko Škrlec |
author_sort |
Mario Dobrilović |
title |
INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION |
title_short |
INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION |
title_full |
INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION |
title_fullStr |
INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION |
title_full_unstemmed |
INCREASING MEASUREMENT ACCURACY IN ELECTRO-OPTICAL METHOD FOR MEASURING VELOCITY OF DETONATION |
title_sort |
increasing measurement accuracy in electro-optical method for measuring velocity of detonation |
publisher |
Faculty of Mining, Geology and Petroleum Engineering |
series |
Rudarsko-geološko-naftni Zbornik |
issn |
0353-4529 1849-0409 |
publishDate |
2014-12-01 |
description |
In addition to other detonation parameters detonation velocity is a value that provides indirect information on the strength i.e. brisance of an explosive and explosive performance. In addition to that, detonation velocity is a value which can be measured in a relatively simpler and more precise manner, by developed and accessible methods when compared to other detonation parameters Due to its simple use, compact instruments and satisfactory accuracy, electro-optical method of detonation velocity measurement is widely used.
The paper describes the electro-optical measurement method and points out the factors that affect its accuracy. The accuracy of measurement is increased and measurement uncertainty is reduced by the measurement result analysis with the application of different measurement setups. |
topic |
velocity of detonation electro-optical method measurement uncertainty |
url |
http://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=199051&lang=en |
work_keys_str_mv |
AT mariodobrilovic increasingmeasurementaccuracyinelectroopticalmethodformeasuringvelocityofdetonation AT vjecislavbohanek increasingmeasurementaccuracyinelectroopticalmethodformeasuringvelocityofdetonation AT vinkoskrlec increasingmeasurementaccuracyinelectroopticalmethodformeasuringvelocityofdetonation |
_version_ |
1725858023333691392 |