The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia
Baekgrouund & purpose: Diagnosis of microcytic hgpochromia is rutinely done using automatied equipment cell counter which is expensive and requaires expert. Personal OFT can be used for this globular defect. The aim of this study is to determine the best NaCL con centration in OFT, the experimen...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mazandaran University of Medical Sciences
2005-01-01
|
Series: | Journal of Mazandaran University of Medical Sciences |
Subjects: | |
Online Access: | http://www.mazums.ac.ir/files/onlineJournals_96507=%20Mahdavi.pdf |
id |
doaj-f028d51d4a56480e905f4a11203a177e |
---|---|
record_format |
Article |
spelling |
doaj-f028d51d4a56480e905f4a11203a177e2020-11-25T00:47:40ZengMazandaran University of Medical SciencesJournal of Mazandaran University of Medical Sciences1735-92602005-01-0115484750The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromiaM. R MahdaviM. KosarainBaekgrouund & purpose: Diagnosis of microcytic hgpochromia is rutinely done using automatied equipment cell counter which is expensive and requaires expert. Personal OFT can be used for this globular defect. The aim of this study is to determine the best NaCL con centration in OFT, the experiments were done at fajer lab in 2001.Material & methods: 696 Random patients were examined simultaneouly for RBV indices by cell counter &method of onetube OFT. In this test .one drop (0.05 m1) of whole blood with 5 m1 of NaCl % 0.4 were mixed for 10 minutes ,and after centrifuging. Supernatal for hemolysis. Result: 382 patients with mcv> 80 had hemolysis . 228 patients with 74< mev <79 had hemolysis. 75 individuals with mcv<75 have no hemolysis and 5 with mcv>80 and 6 with 74<mwv<79 had no hemolysis.Conclusion: one tube OFT is very Sensetive for sereening of microcytic hypochromia but it is not practical for differential diagnosis of iron deficieney anenaia from minor thlassemia http://www.mazums.ac.ir/files/onlineJournals_96507=%20Mahdavi.pdfThalassemia screeningOne tubeOsmotic fragility test |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
M. R Mahdavi M. Kosarain |
spellingShingle |
M. R Mahdavi M. Kosarain The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia Journal of Mazandaran University of Medical Sciences Thalassemia screening One tube Osmotic fragility test |
author_facet |
M. R Mahdavi M. Kosarain |
author_sort |
M. R Mahdavi |
title |
The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia |
title_short |
The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia |
title_full |
The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia |
title_fullStr |
The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia |
title_full_unstemmed |
The strength of osmotic fragility test (OFT) in diagosis of microlcytic hypochromia |
title_sort |
strength of osmotic fragility test (oft) in diagosis of microlcytic hypochromia |
publisher |
Mazandaran University of Medical Sciences |
series |
Journal of Mazandaran University of Medical Sciences |
issn |
1735-9260 |
publishDate |
2005-01-01 |
description |
Baekgrouund & purpose: Diagnosis of microcytic hgpochromia is rutinely done using automatied equipment cell counter which is expensive and requaires expert. Personal OFT can be used for this globular defect. The aim of this study is to determine the best NaCL con centration in OFT, the experiments were done at fajer lab in 2001.Material & methods: 696 Random patients were examined simultaneouly for RBV indices by cell counter &method of onetube OFT. In this test .one drop (0.05 m1) of whole blood with 5 m1 of NaCl % 0.4 were mixed for 10 minutes ,and after centrifuging. Supernatal for hemolysis. Result: 382 patients with mcv> 80 had hemolysis . 228 patients with 74< mev <79 had hemolysis. 75 individuals with mcv<75 have no hemolysis and 5 with mcv>80 and 6 with 74<mwv<79 had no hemolysis.Conclusion: one tube OFT is very Sensetive for sereening of microcytic hypochromia but it is not practical for differential diagnosis of iron deficieney anenaia from minor thlassemia |
topic |
Thalassemia screening One tube Osmotic fragility test |
url |
http://www.mazums.ac.ir/files/onlineJournals_96507=%20Mahdavi.pdf |
work_keys_str_mv |
AT mrmahdavi thestrengthofosmoticfragilitytestoftindiagosisofmicrolcytichypochromia AT mkosarain thestrengthofosmoticfragilitytestoftindiagosisofmicrolcytichypochromia AT mrmahdavi strengthofosmoticfragilitytestoftindiagosisofmicrolcytichypochromia AT mkosarain strengthofosmoticfragilitytestoftindiagosisofmicrolcytichypochromia |
_version_ |
1725259214176124928 |