Inclination measurement device for hospital beds’ in ICU

Ventilator-associated pneumonia is acquired by many patients connected to an artificial airway, causing their death of a great percentage to those who are affected. A close relationship has been found between ventilator-associated pneumonia and hospital beds tilting angle which the patients rest on....

Full description

Bibliographic Details
Main Authors: Daniela Naranjo López, María Alejandra González Jiménez, Sebastián Buitrago Toro, Jonathan Gallego Londoño
Format: Article
Language:English
Published: Universidad Distrital Francisco José de Caldas 2019-01-01
Series:Visión Electrónica
Subjects:
Online Access:https://revistas.udistrital.edu.co/index.php/visele/article/view/14408
id doaj-ef4168652f6b40d99b406534347b32f4
record_format Article
spelling doaj-ef4168652f6b40d99b406534347b32f42020-11-25T02:20:22ZengUniversidad Distrital Francisco José de CaldasVisión Electrónica1909-97462248-47282019-01-011319210010.14483/22484728.1440814408Inclination measurement device for hospital beds’ in ICUDaniela Naranjo LópezMaría Alejandra González JiménezSebastián Buitrago ToroJonathan Gallego LondoñoVentilator-associated pneumonia is acquired by many patients connected to an artificial airway, causing their death of a great percentage to those who are affected. A close relationship has been found between ventilator-associated pneumonia and hospital beds tilting angle which the patients rest on. The correct position has been established between 30° and 45° to reduce the likelihood of ventilator-associated pneumonia; so a tilt sensor linked to the hospital beds is a good method for measuring. The present article describes an electronic device which was developed able to create a link between an IMU sensor connected to a microcontroller and a Wi-Fi module that allows to display, in a real time graphical interface, located in the control center, the current position of hospital’s beds for being monitored by the nursing staff providing a record of the patients’ status in intensive care and emergency units. Device’s performance was checked by hysteresis and fixed position test along a previously defined time where errors in measurement of inclination remain within a suitable range.https://revistas.udistrital.edu.co/index.php/visele/article/view/14408inertial measurement unitmechanical ventilationtilt angleventilator-associated pneumoniawi-fi communication
collection DOAJ
language English
format Article
sources DOAJ
author Daniela Naranjo López
María Alejandra González Jiménez
Sebastián Buitrago Toro
Jonathan Gallego Londoño
spellingShingle Daniela Naranjo López
María Alejandra González Jiménez
Sebastián Buitrago Toro
Jonathan Gallego Londoño
Inclination measurement device for hospital beds’ in ICU
Visión Electrónica
inertial measurement unit
mechanical ventilation
tilt angle
ventilator-associated pneumonia
wi-fi communication
author_facet Daniela Naranjo López
María Alejandra González Jiménez
Sebastián Buitrago Toro
Jonathan Gallego Londoño
author_sort Daniela Naranjo López
title Inclination measurement device for hospital beds’ in ICU
title_short Inclination measurement device for hospital beds’ in ICU
title_full Inclination measurement device for hospital beds’ in ICU
title_fullStr Inclination measurement device for hospital beds’ in ICU
title_full_unstemmed Inclination measurement device for hospital beds’ in ICU
title_sort inclination measurement device for hospital beds’ in icu
publisher Universidad Distrital Francisco José de Caldas
series Visión Electrónica
issn 1909-9746
2248-4728
publishDate 2019-01-01
description Ventilator-associated pneumonia is acquired by many patients connected to an artificial airway, causing their death of a great percentage to those who are affected. A close relationship has been found between ventilator-associated pneumonia and hospital beds tilting angle which the patients rest on. The correct position has been established between 30° and 45° to reduce the likelihood of ventilator-associated pneumonia; so a tilt sensor linked to the hospital beds is a good method for measuring. The present article describes an electronic device which was developed able to create a link between an IMU sensor connected to a microcontroller and a Wi-Fi module that allows to display, in a real time graphical interface, located in the control center, the current position of hospital’s beds for being monitored by the nursing staff providing a record of the patients’ status in intensive care and emergency units. Device’s performance was checked by hysteresis and fixed position test along a previously defined time where errors in measurement of inclination remain within a suitable range.
topic inertial measurement unit
mechanical ventilation
tilt angle
ventilator-associated pneumonia
wi-fi communication
url https://revistas.udistrital.edu.co/index.php/visele/article/view/14408
work_keys_str_mv AT danielanaranjolopez inclinationmeasurementdeviceforhospitalbedsinicu
AT mariaalejandragonzalezjimenez inclinationmeasurementdeviceforhospitalbedsinicu
AT sebastianbuitragotoro inclinationmeasurementdeviceforhospitalbedsinicu
AT jonathangallegolondono inclinationmeasurementdeviceforhospitalbedsinicu
_version_ 1724871818841423872