The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care Ultrasound

Giriş: Acil servis ve yoğun bakımdaki hastaların; tanı, tedavi ve takibinde intravasküler volüm durumunun, doğru ve hızlı şekilde tespiti oldukça önemli ve bir o kadar da zordur. Hemodinamik izlemin amacı kardiyovasküler yetmezliği belirlemek ve stabil olmayan kritik düzeydeki hastalara (septik şok,...

Full description

Bibliographic Details
Main Authors: Meltem İnce, Metin Ocak
Format: Article
Language:English
Published: Rabia Yılmaz 2020-12-01
Series:Journal of Contemporary Medicine
Subjects:
Online Access:https://dergipark.org.tr/tr/pub/jcm/issue/54171/728902?publisher=rabia-yilmaz
id doaj-eebe13c7f1bb44e0a49bc3dd31408726
record_format Article
spelling doaj-eebe13c7f1bb44e0a49bc3dd314087262020-12-07T19:58:29ZengRabia YılmazJournal of Contemporary Medicine2667-71802020-12-01104171809The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care UltrasoundMeltem İnce0Metin OcakSAMSUN GAZİ DEVLET HASTANESİGiriş: Acil servis ve yoğun bakımdaki hastaların; tanı, tedavi ve takibinde intravasküler volüm durumunun, doğru ve hızlı şekilde tespiti oldukça önemli ve bir o kadar da zordur. Hemodinamik izlemin amacı kardiyovasküler yetmezliği belirlemek ve stabil olmayan kritik düzeydeki hastalara (septik şok, hipovolemi, kardiyojenik şok v.b.) en uygun tedaviyi sağlamaktır. Amaç: Bu çalışmada amacımız; acil servis ve yoğun bakım ünitesinde, intravasküler volüm durumunu değerlendirmede ve doğru volüm replasmanına yönlenmede ultrasonografi ile vena cava inferior çapı ,vena cava inferior - kollapsibilite indeksi (spontan solunumu olan hastalar için) ve vena cava inferior distensibilite indeksi (mekanik ventilasyon desteğinde soluyan hastalar için) ölçümünün invaziv kateter yerleştirilerek yapılan santral venöz basınç değeri ile karşılaştırılması ve arasındaki ilişkinin saptanmasıdır. Gereç ve Yöntem: Bu çalışma acil tıp kliniğine 01.06.2014-01.04.2015 tarihleri arasında başvuran veya bu tarihler arasında acil yoğun bakım ünitesinde yatmakta olan, herhangi bir endikasyon ile santral venöz kateter takılan 18 yaş üstü hastalar üzerinde prospektif olarak yürütüldü. Vena cava inferiordan ultrasonografik M mod kullanılarak, hem inspiryum hem de ekspiryum fazında ölçümler alındı ve milimetre cinsinden kaydedildi. Hastalardan eş zamanlı santral venöz basınç ölçümü monometrik cihazlar ile yapıldı ve sonuçlar cm H2O cinsinden kayıt altına alındı. Bulgular: Hastaların % 43.3’ü kadın (n:26), % 56.7’si erkek (n:34) olup, yaş ortalamaları 70.58 ± 14.86 yıl idi. Santral venöz basınç ile vena cava inferior çapları arasında pozitif yönde, vena cava inferior- kollapsibilite indeksi arasında negatif yönde yüksek derecede korelasyon tespit edildi. Çalışmamızda ayrıca mekanik ventilatör ile solunumu sağlanan hastalarda da vena cava inferior- distensibilite indeksi ve santral venöz basınç arasında negatif yönde yüksek derecede korelasyon olduğu saptandı. Sonuç: Acil servis ve yoğun bakım ünitelerinde mekanik ventile ya da spontan solunuma sahip olan kritik hastalarda; hızlı, güvenilir, kolay uygulanabilir, maliyeti düşük ve noninvaziv bir yöntem olan ultrasonografi ile vena cava inferior çapındaki respiratuar değişkenlik ölçümü; volüm durumunu değerlendirmede ve santral venöz basıncı tahmin etmede kullanılabilir.https://dergipark.org.tr/tr/pub/jcm/issue/54171/728902?publisher=rabia-yilmazsantral venöz basınçvena cava inferiorultrasonografivolüm durumucentral venous pressurevena cava inferiorultrasonographyvolume status
collection DOAJ
language English
format Article
sources DOAJ
author Meltem İnce
Metin Ocak
spellingShingle Meltem İnce
Metin Ocak
The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care Ultrasound
Journal of Contemporary Medicine
santral venöz basınç
vena cava inferior
ultrasonografi
volüm durumu
central venous pressure
vena cava inferior
ultrasonography
volume status
author_facet Meltem İnce
Metin Ocak
author_sort Meltem İnce
title The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care Ultrasound
title_short The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care Ultrasound
title_full The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care Ultrasound
title_fullStr The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care Ultrasound
title_full_unstemmed The Most Useful Method To Evaluate The Volume Status Of Critical Patients In The Emergency And Intensive Care Units: Point Of Care Ultrasound
title_sort most useful method to evaluate the volume status of critical patients in the emergency and intensive care units: point of care ultrasound
publisher Rabia Yılmaz
series Journal of Contemporary Medicine
issn 2667-7180
publishDate 2020-12-01
description Giriş: Acil servis ve yoğun bakımdaki hastaların; tanı, tedavi ve takibinde intravasküler volüm durumunun, doğru ve hızlı şekilde tespiti oldukça önemli ve bir o kadar da zordur. Hemodinamik izlemin amacı kardiyovasküler yetmezliği belirlemek ve stabil olmayan kritik düzeydeki hastalara (septik şok, hipovolemi, kardiyojenik şok v.b.) en uygun tedaviyi sağlamaktır. Amaç: Bu çalışmada amacımız; acil servis ve yoğun bakım ünitesinde, intravasküler volüm durumunu değerlendirmede ve doğru volüm replasmanına yönlenmede ultrasonografi ile vena cava inferior çapı ,vena cava inferior - kollapsibilite indeksi (spontan solunumu olan hastalar için) ve vena cava inferior distensibilite indeksi (mekanik ventilasyon desteğinde soluyan hastalar için) ölçümünün invaziv kateter yerleştirilerek yapılan santral venöz basınç değeri ile karşılaştırılması ve arasındaki ilişkinin saptanmasıdır. Gereç ve Yöntem: Bu çalışma acil tıp kliniğine 01.06.2014-01.04.2015 tarihleri arasında başvuran veya bu tarihler arasında acil yoğun bakım ünitesinde yatmakta olan, herhangi bir endikasyon ile santral venöz kateter takılan 18 yaş üstü hastalar üzerinde prospektif olarak yürütüldü. Vena cava inferiordan ultrasonografik M mod kullanılarak, hem inspiryum hem de ekspiryum fazında ölçümler alındı ve milimetre cinsinden kaydedildi. Hastalardan eş zamanlı santral venöz basınç ölçümü monometrik cihazlar ile yapıldı ve sonuçlar cm H2O cinsinden kayıt altına alındı. Bulgular: Hastaların % 43.3’ü kadın (n:26), % 56.7’si erkek (n:34) olup, yaş ortalamaları 70.58 ± 14.86 yıl idi. Santral venöz basınç ile vena cava inferior çapları arasında pozitif yönde, vena cava inferior- kollapsibilite indeksi arasında negatif yönde yüksek derecede korelasyon tespit edildi. Çalışmamızda ayrıca mekanik ventilatör ile solunumu sağlanan hastalarda da vena cava inferior- distensibilite indeksi ve santral venöz basınç arasında negatif yönde yüksek derecede korelasyon olduğu saptandı. Sonuç: Acil servis ve yoğun bakım ünitelerinde mekanik ventile ya da spontan solunuma sahip olan kritik hastalarda; hızlı, güvenilir, kolay uygulanabilir, maliyeti düşük ve noninvaziv bir yöntem olan ultrasonografi ile vena cava inferior çapındaki respiratuar değişkenlik ölçümü; volüm durumunu değerlendirmede ve santral venöz basıncı tahmin etmede kullanılabilir.
topic santral venöz basınç
vena cava inferior
ultrasonografi
volüm durumu
central venous pressure
vena cava inferior
ultrasonography
volume status
url https://dergipark.org.tr/tr/pub/jcm/issue/54171/728902?publisher=rabia-yilmaz
work_keys_str_mv AT meltemince themostusefulmethodtoevaluatethevolumestatusofcriticalpatientsintheemergencyandintensivecareunitspointofcareultrasound
AT metinocak themostusefulmethodtoevaluatethevolumestatusofcriticalpatientsintheemergencyandintensivecareunitspointofcareultrasound
AT meltemince mostusefulmethodtoevaluatethevolumestatusofcriticalpatientsintheemergencyandintensivecareunitspointofcareultrasound
AT metinocak mostusefulmethodtoevaluatethevolumestatusofcriticalpatientsintheemergencyandintensivecareunitspointofcareultrasound
_version_ 1724397325760069632