Modified technique and clinical application of central hole ICL implantation for 2a

AIM: To explore the application of improved skills in central hole ICL V4c implantation and its clinical efficacy. <p>METHODS: This study included 141 eyes of 72 patients with myopia from September 2015 to August 2016. An implantable contact lens with a central hole(ICL V4c)was inserted by imp...

Full description

Bibliographic Details
Main Authors: Wu-Mu Bi, Kang Sun, Lin-Hui Zhong, Rui-Juan Wang, Xia Guo, Jing Liu
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2019-07-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2019/7/201907029.pdf
id doaj-ee72c590e23b431286c8a779a7e949e3
record_format Article
spelling doaj-ee72c590e23b431286c8a779a7e949e32020-11-25T02:44:11ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51231672-51232019-07-011971208121110.3980/j.issn.1672-5123.2019.7.29Modified technique and clinical application of central hole ICL implantation for 2aWu-Mu Bi0Kang Sun1Lin-Hui Zhong2Rui-Juan Wang3Xia Guo4Jing Liu5Huizhou Aier Ophthalmology Hospital of Aier Ophthalmology Group, Huizhou 516000, Guangdong Province, ChinaHuizhou Aier Ophthalmology Hospital of Aier Ophthalmology Group, Huizhou 516000, Guangdong Province, ChinaHuizhou Aier Ophthalmology Hospital of Aier Ophthalmology Group, Huizhou 516000, Guangdong Province, ChinaHuizhou Aier Ophthalmology Hospital of Aier Ophthalmology Group, Huizhou 516000, Guangdong Province, ChinaHuizhou Aier Ophthalmology Hospital of Aier Ophthalmology Group, Huizhou 516000, Guangdong Province, ChinaHuizhou Aier Ophthalmology Hospital of Aier Ophthalmology Group, Huizhou 516000, Guangdong Province, ChinaAIM: To explore the application of improved skills in central hole ICL V4c implantation and its clinical efficacy. <p>METHODS: This study included 141 eyes of 72 patients with myopia from September 2015 to August 2016. An implantable contact lens with a central hole(ICL V4c)was inserted by improved surgical skills including single 2.8mm clear corneal incision, no anterior chamber viscoelastics before ICL implantation. The intraocular pressure(IOP)was measured at the early stage within 6h after operation. The visual acuity, diopter, intraocular pressure and corneal endothelial cell density were observed after operation and follow up 2a. <p>RESULTS: ICL V4c was implanted successfully in all patients by this improved skills and fine clinical results were achieved. Elevated IOP is possible at early stage post-operation, especially within 2h after operation. 95.7% had normal IOP 6h after operation. The postoperative IOP was stable within 2a follow-up period. The cumulative corneal endothelial loss rates of 6mo, 1a and 2a were 4.70%, 7.59% and 9.63% respectively. There was no complications such as subcapsular cataract during the 2a follow-up period.<p>CONCLUSION: The improved skills used in our study is safe and feasible.http://ies.ijo.cn/cn_publish/2019/7/201907029.pdfcentral hole ICL V4cposterior chamber phakic intraocular lensimproved techniqueintraocular pressurecorneal endothelial loss
collection DOAJ
language English
format Article
sources DOAJ
author Wu-Mu Bi
Kang Sun
Lin-Hui Zhong
Rui-Juan Wang
Xia Guo
Jing Liu
spellingShingle Wu-Mu Bi
Kang Sun
Lin-Hui Zhong
Rui-Juan Wang
Xia Guo
Jing Liu
Modified technique and clinical application of central hole ICL implantation for 2a
Guoji Yanke Zazhi
central hole ICL V4c
posterior chamber phakic intraocular lens
improved technique
intraocular pressure
corneal endothelial loss
author_facet Wu-Mu Bi
Kang Sun
Lin-Hui Zhong
Rui-Juan Wang
Xia Guo
Jing Liu
author_sort Wu-Mu Bi
title Modified technique and clinical application of central hole ICL implantation for 2a
title_short Modified technique and clinical application of central hole ICL implantation for 2a
title_full Modified technique and clinical application of central hole ICL implantation for 2a
title_fullStr Modified technique and clinical application of central hole ICL implantation for 2a
title_full_unstemmed Modified technique and clinical application of central hole ICL implantation for 2a
title_sort modified technique and clinical application of central hole icl implantation for 2a
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series Guoji Yanke Zazhi
issn 1672-5123
1672-5123
publishDate 2019-07-01
description AIM: To explore the application of improved skills in central hole ICL V4c implantation and its clinical efficacy. <p>METHODS: This study included 141 eyes of 72 patients with myopia from September 2015 to August 2016. An implantable contact lens with a central hole(ICL V4c)was inserted by improved surgical skills including single 2.8mm clear corneal incision, no anterior chamber viscoelastics before ICL implantation. The intraocular pressure(IOP)was measured at the early stage within 6h after operation. The visual acuity, diopter, intraocular pressure and corneal endothelial cell density were observed after operation and follow up 2a. <p>RESULTS: ICL V4c was implanted successfully in all patients by this improved skills and fine clinical results were achieved. Elevated IOP is possible at early stage post-operation, especially within 2h after operation. 95.7% had normal IOP 6h after operation. The postoperative IOP was stable within 2a follow-up period. The cumulative corneal endothelial loss rates of 6mo, 1a and 2a were 4.70%, 7.59% and 9.63% respectively. There was no complications such as subcapsular cataract during the 2a follow-up period.<p>CONCLUSION: The improved skills used in our study is safe and feasible.
topic central hole ICL V4c
posterior chamber phakic intraocular lens
improved technique
intraocular pressure
corneal endothelial loss
url http://ies.ijo.cn/cn_publish/2019/7/201907029.pdf
work_keys_str_mv AT wumubi modifiedtechniqueandclinicalapplicationofcentralholeiclimplantationfor2a
AT kangsun modifiedtechniqueandclinicalapplicationofcentralholeiclimplantationfor2a
AT linhuizhong modifiedtechniqueandclinicalapplicationofcentralholeiclimplantationfor2a
AT ruijuanwang modifiedtechniqueandclinicalapplicationofcentralholeiclimplantationfor2a
AT xiaguo modifiedtechniqueandclinicalapplicationofcentralholeiclimplantationfor2a
AT jingliu modifiedtechniqueandclinicalapplicationofcentralholeiclimplantationfor2a
_version_ 1724766863599075328