Method for reducing x-ray background signals from insertion device x-ray beam position monitors
A method is described that provides a solution to the long-standing problem of stray radiation-induced signals on photoemission-based x-ray beam position monitors (BPMs) located on insertion device x-ray beam lines. The method involves the introduction of a chicane into the accelerator lattice that...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
American Physical Society
1999-11-01
|
Series: | Physical Review Special Topics. Accelerators and Beams |
Online Access: | http://doi.org/10.1103/PhysRevSTAB.2.112801 |
id |
doaj-ee686951c87c43ffa39f5e299b4775e5 |
---|---|
record_format |
Article |
spelling |
doaj-ee686951c87c43ffa39f5e299b4775e52020-11-25T01:18:05ZengAmerican Physical SocietyPhysical Review Special Topics. Accelerators and Beams1098-44021999-11-0121111280110.1103/PhysRevSTAB.2.112801Method for reducing x-ray background signals from insertion device x-ray beam position monitorsGlenn DeckerOm SinghA method is described that provides a solution to the long-standing problem of stray radiation-induced signals on photoemission-based x-ray beam position monitors (BPMs) located on insertion device x-ray beam lines. The method involves the introduction of a chicane into the accelerator lattice that directs unwanted x radiation away from the photosensitive x-ray BPM blades. This technique has been implemented at the Advanced Photon Source, and experimental confirmation of the technique is provided.http://doi.org/10.1103/PhysRevSTAB.2.112801 |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Glenn Decker Om Singh |
spellingShingle |
Glenn Decker Om Singh Method for reducing x-ray background signals from insertion device x-ray beam position monitors Physical Review Special Topics. Accelerators and Beams |
author_facet |
Glenn Decker Om Singh |
author_sort |
Glenn Decker |
title |
Method for reducing x-ray background signals from insertion device x-ray beam position monitors |
title_short |
Method for reducing x-ray background signals from insertion device x-ray beam position monitors |
title_full |
Method for reducing x-ray background signals from insertion device x-ray beam position monitors |
title_fullStr |
Method for reducing x-ray background signals from insertion device x-ray beam position monitors |
title_full_unstemmed |
Method for reducing x-ray background signals from insertion device x-ray beam position monitors |
title_sort |
method for reducing x-ray background signals from insertion device x-ray beam position monitors |
publisher |
American Physical Society |
series |
Physical Review Special Topics. Accelerators and Beams |
issn |
1098-4402 |
publishDate |
1999-11-01 |
description |
A method is described that provides a solution to the long-standing problem of stray radiation-induced signals on photoemission-based x-ray beam position monitors (BPMs) located on insertion device x-ray beam lines. The method involves the introduction of a chicane into the accelerator lattice that directs unwanted x radiation away from the photosensitive x-ray BPM blades. This technique has been implemented at the Advanced Photon Source, and experimental confirmation of the technique is provided. |
url |
http://doi.org/10.1103/PhysRevSTAB.2.112801 |
work_keys_str_mv |
AT glenndecker methodforreducingxraybackgroundsignalsfrominsertiondevicexraybeampositionmonitors AT omsingh methodforreducingxraybackgroundsignalsfrominsertiondevicexraybeampositionmonitors |
_version_ |
1725143730079399936 |