Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects

Aims: To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance. Patients and Methods: The sample comprised...

Full description

Bibliographic Details
Main Author: Chintan Malhotra
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2009-01-01
Series:Oman Journal of Ophthalmology
Subjects:
Online Access:http://www.ojoonline.org/article.asp?issn=0974-620X;year=2009;volume=2;issue=1;spage=27;epage=32;aulast=Malhotra
id doaj-ee40199a45b44ebe9c51c0563b62bad0
record_format Article
spelling doaj-ee40199a45b44ebe9c51c0563b62bad02020-11-25T01:41:42ZengWolters Kluwer Medknow PublicationsOman Journal of Ophthalmology0974-620X2009-01-0121273210.4103/0974-620X.48419Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjectsChintan MalhotraAims: To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance. Patients and Methods: The sample comprised 30 patients of stable POAG (group 1) and 20 age-matched normal controls (group2) who performed both SWAP and W-W perimetry thrice at monthly intervals. Long-term variability at each location in the visual field was calculated as the standard deviation of three threshold decibel values taken from the three visual fields performed. Mean LTV was then calculated for the entire field for each subgroup and compared. Results: Mean LTV in SWAP and W-W perimetry in glaucoma patients was 3.01 ± 0.74 dB and 2.73 ± 1.07dB respectively. In normal subjects mean LTV of SWAP and W-W perimetry was 2.69 ± 0.91 db and 1.97 ± 1.34 dB respectively. Intra group analysis revealed that mean LTV of SWAP was greater compared to W-W perimetry in normal subjects and glaucoma patients. In the latter, the difference did not reach statistical significance. Inter group analysis showed that mean LTV in both SWAP and W-W perimetry was greater in glaucoma patients than in normal subjects. Factors other than POAG that could influence LTV, including progression of cataract and change in pupil size due to use of pilocarpine were excluded. Mean examination time for SWAP per sitting was 7.65% longer than that for W-W perimetry. Conclusions: Higher mean LTV of SWAP as compared to W-W perimetry needs to be taken into consideration when evaluating serial visual fields for change. Use of rapid threshold algorithms e.g. SITA (Swedish interactive test algorithm) SWAP should be encouraged as these will reduce the patient fatigue and increase the reliability of the test.http://www.ojoonline.org/article.asp?issn=0974-620X;year=2009;volume=2;issue=1;spage=27;epage=32;aulast=MalhotraLong-term variabilityshort-wavelength automated perimetrywhite-on-white perimetry
collection DOAJ
language English
format Article
sources DOAJ
author Chintan Malhotra
spellingShingle Chintan Malhotra
Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
Oman Journal of Ophthalmology
Long-term variability
short-wavelength automated perimetry
white-on-white perimetry
author_facet Chintan Malhotra
author_sort Chintan Malhotra
title Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_short Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_full Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_fullStr Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_full_unstemmed Long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
title_sort long-term variability in short-wavelength automated perimetry compared to standard perimetry in glaucoma patients and normal subjects
publisher Wolters Kluwer Medknow Publications
series Oman Journal of Ophthalmology
issn 0974-620X
publishDate 2009-01-01
description Aims: To compare long-term variability (LTV) in short-wavelength automated perimetry (SWAP) with that of standard white-on-white (W-W) perimetry, in primary open angle glaucoma (POAG) patients and normal subjects and to determine its clinical significance. Patients and Methods: The sample comprised 30 patients of stable POAG (group 1) and 20 age-matched normal controls (group2) who performed both SWAP and W-W perimetry thrice at monthly intervals. Long-term variability at each location in the visual field was calculated as the standard deviation of three threshold decibel values taken from the three visual fields performed. Mean LTV was then calculated for the entire field for each subgroup and compared. Results: Mean LTV in SWAP and W-W perimetry in glaucoma patients was 3.01 ± 0.74 dB and 2.73 ± 1.07dB respectively. In normal subjects mean LTV of SWAP and W-W perimetry was 2.69 ± 0.91 db and 1.97 ± 1.34 dB respectively. Intra group analysis revealed that mean LTV of SWAP was greater compared to W-W perimetry in normal subjects and glaucoma patients. In the latter, the difference did not reach statistical significance. Inter group analysis showed that mean LTV in both SWAP and W-W perimetry was greater in glaucoma patients than in normal subjects. Factors other than POAG that could influence LTV, including progression of cataract and change in pupil size due to use of pilocarpine were excluded. Mean examination time for SWAP per sitting was 7.65% longer than that for W-W perimetry. Conclusions: Higher mean LTV of SWAP as compared to W-W perimetry needs to be taken into consideration when evaluating serial visual fields for change. Use of rapid threshold algorithms e.g. SITA (Swedish interactive test algorithm) SWAP should be encouraged as these will reduce the patient fatigue and increase the reliability of the test.
topic Long-term variability
short-wavelength automated perimetry
white-on-white perimetry
url http://www.ojoonline.org/article.asp?issn=0974-620X;year=2009;volume=2;issue=1;spage=27;epage=32;aulast=Malhotra
work_keys_str_mv AT chintanmalhotra longtermvariabilityinshortwavelengthautomatedperimetrycomparedtostandardperimetryinglaucomapatientsandnormalsubjects
_version_ 1725040170706665472