Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional Floors

This study intends to analyze and design existing RC frames, of different concrete compressive strengths when extended by adding more floors to the existing buildings. It may be decided whether a strengthening scheme is feasible or not.In this work, analyses are made of 3 buildings of 14-stories wit...

Full description

Bibliographic Details
Main Author: Bayan S. Al-Nu’man
Format: Article
Language:English
Published: Ishik University 2016-12-01
Series:Eurasian Journal of Science and Engineering
Subjects:
Online Access:http://eajse.org/wp-content/uploads/2017/02/28-40.pdf
id doaj-ee0964e675ad4034902e8a7236e794a6
record_format Article
spelling doaj-ee0964e675ad4034902e8a7236e794a62020-11-25T01:56:41ZengIshik UniversityEurasian Journal of Science and Engineering2414-56292414-56022016-12-0121284010.23918/eajse.2414214Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional FloorsBayan S. Al-Nu’manThis study intends to analyze and design existing RC frames, of different concrete compressive strengths when extended by adding more floors to the existing buildings. It may be decided whether a strengthening scheme is feasible or not.In this work, analyses are made of 3 buildings of 14-stories with different compressive strengths in the first 6-floor columns for each building, extended to 16-stories frame by adding 2 stories of Normal weight concrete (NWC) or Steel.A case study is selected which is an existing RC buildings, and the owner requested 2 additional floors. It is assumed that the foundation system is capable of carrying the additional floors. First the capacity of the superstructures must be known, by using data obtained from the previous designs of the existing buildings.After extending the building by NWC or Steel, by using STAAD-pro, it has been shown that a considerable portion of the total number of columns in the superstructure of the existing building couldn’t carry the new loads due to the additional 2 floors, so in order to add two additional floors, strengthening scheme must be planned for the columns which require additional capacity.http://eajse.org/wp-content/uploads/2017/02/28-40.pdfExisting BuildingAdditional FloorStrengthen
collection DOAJ
language English
format Article
sources DOAJ
author Bayan S. Al-Nu’man
spellingShingle Bayan S. Al-Nu’man
Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional Floors
Eurasian Journal of Science and Engineering
Existing Building
Additional Floor
Strengthen
author_facet Bayan S. Al-Nu’man
author_sort Bayan S. Al-Nu’man
title Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional Floors
title_short Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional Floors
title_full Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional Floors
title_fullStr Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional Floors
title_full_unstemmed Assessment of Strengthening Scheme of Existing Buildings Extended by Adding Additional Floors
title_sort assessment of strengthening scheme of existing buildings extended by adding additional floors
publisher Ishik University
series Eurasian Journal of Science and Engineering
issn 2414-5629
2414-5602
publishDate 2016-12-01
description This study intends to analyze and design existing RC frames, of different concrete compressive strengths when extended by adding more floors to the existing buildings. It may be decided whether a strengthening scheme is feasible or not.In this work, analyses are made of 3 buildings of 14-stories with different compressive strengths in the first 6-floor columns for each building, extended to 16-stories frame by adding 2 stories of Normal weight concrete (NWC) or Steel.A case study is selected which is an existing RC buildings, and the owner requested 2 additional floors. It is assumed that the foundation system is capable of carrying the additional floors. First the capacity of the superstructures must be known, by using data obtained from the previous designs of the existing buildings.After extending the building by NWC or Steel, by using STAAD-pro, it has been shown that a considerable portion of the total number of columns in the superstructure of the existing building couldn’t carry the new loads due to the additional 2 floors, so in order to add two additional floors, strengthening scheme must be planned for the columns which require additional capacity.
topic Existing Building
Additional Floor
Strengthen
url http://eajse.org/wp-content/uploads/2017/02/28-40.pdf
work_keys_str_mv AT bayansalnuman assessmentofstrengtheningschemeofexistingbuildingsextendedbyaddingadditionalfloors
_version_ 1724978613082652672