Moisture in walls before and after internal wall insulation: a long-term in-situ dataset
This work addresses the need for long-term, high-resolution, in-situ datasets by providing in-wall humidity and temperature data from three walls of in-use office buildings over three to four years, two of which were insulated during this period. Temperature and humidity sensors were inserted diagon...
Main Authors: | Grint Naomi, Elwell Clifford A. |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2020-01-01
|
Series: | E3S Web of Conferences |
Online Access: | https://www.e3s-conferences.org/articles/e3sconf/pdf/2020/32/e3sconf_nsb2020_01005.pdf |