Lumen-apposing metal stents versus biliary fully-covered metal stents for EUS-guided drainage of pancreatic fluid collections: a case control study
Background and study aims Endoscopic ultrasound (EUS)-guided drainage has become first-line treatment for pancreatic fluid collections (PFC). The aim of this study was to compare the effectiveness and safety of biliary fully-covered self-expandable metal stents (BFCSEMS) and lumen-apposing metal ste...
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Georg Thieme Verlag KG
2020-01-01
|
Series: | Endoscopy International Open |
Online Access: | http://www.thieme-connect.de/DOI/DOI?10.1055/a-1031-9295 |
Summary: | Background and study aims Endoscopic ultrasound (EUS)-guided drainage has become first-line treatment for pancreatic fluid collections (PFC). The aim of this study was to compare the effectiveness and safety of biliary fully-covered self-expandable metal stents (BFCSEMS) and lumen-apposing metal stents with electrocautery (EC-LAMS).
Patients and methods From April 2008 to March 2017, consecutive patients with symptomatic PFC drained under EUS-guidance with metal stents were included. Patients drained with EC-LAMS were considered the study group and those drained with BFCSEMS the control group. Two primary endpoints were evaluated: effectiveness (defined as reduction of ≥ 50 % of PFC size in cross-sectional imaging and improvement of symptoms 6 months after the transmural drainage) and safety.
Results Thirty patients were drained with EC-LAMS and 60 patients with BFCSEMS. Patients and PFC baseline characteristics in both groups were similar. Use of a coaxial double pigtail plastic stent and a nasocystic lavage catheter was significantly less frequent in patients drained with EC-LAMS (33 % vs. 100 %, and 13 % vs. 58 %, respectively; P < 0.0001). Technical success was 100 % in both groups. Procedure time was < 30 minutes in all patients drained with EC-LAMS and over 30 minutes in all patients drained with BFCSEMS (P = 0.0001). Clinical success was higher with a tendency to significance in patients drained with EC-LAMS (96 % vs. 82 %, P = 0.055) and the adverse event rate was lower (4 % vs. 18 %, P = 0.04). No case of procedure-related mortality was recorded.
Conclusions EC-LAMS and BFCSEMS are both effective for EUS-guided drainage of PFC. However, EC-LAMS requires less time to be performed and appears to be safer. |
---|---|
ISSN: | 2364-3722 2196-9736 |