Lumen-apposing metal stents versus biliary fully-covered metal stents for EUS-guided drainage of pancreatic fluid collections: a case control study

Background and study aims Endoscopic ultrasound (EUS)-guided drainage has become first-line treatment for pancreatic fluid collections (PFC). The aim of this study was to compare the effectiveness and safety of biliary fully-covered self-expandable metal stents (BFCSEMS) and lumen-apposing metal ste...

Full description

Bibliographic Details
Main Authors: Ana Garcia Garcia de Paredes, Juan Angel Gonzalez Martin, Jose Ramon Foruny Olcina, Diego Juzgado Lucas, Fernando Gonzalez Panizo, Sergio Lopez Duran, Alba Martinez Sanchez, Alfonso Sanjuanbenito, Alejandra Caminoa, Agustin Albillos, Enrique Vazquez-Sequeiros
Format: Article
Language:English
Published: Georg Thieme Verlag KG 2020-01-01
Series:Endoscopy International Open
Online Access:http://www.thieme-connect.de/DOI/DOI?10.1055/a-1031-9295
Description
Summary:Background and study aims Endoscopic ultrasound (EUS)-guided drainage has become first-line treatment for pancreatic fluid collections (PFC). The aim of this study was to compare the effectiveness and safety of biliary fully-covered self-expandable metal stents (BFCSEMS) and lumen-apposing metal stents with electrocautery (EC-LAMS). Patients and methods From April 2008 to March 2017, consecutive patients with symptomatic PFC drained under EUS-guidance with metal stents were included. Patients drained with EC-LAMS were considered the study group and those drained with BFCSEMS the control group. Two primary endpoints were evaluated: effectiveness (defined as reduction of ≥ 50 % of PFC size in cross-sectional imaging and improvement of symptoms 6 months after the transmural drainage) and safety. Results Thirty patients were drained with EC-LAMS and 60 patients with BFCSEMS. Patients and PFC baseline characteristics in both groups were similar. Use of a coaxial double pigtail plastic stent and a nasocystic lavage catheter was significantly less frequent in patients drained with EC-LAMS (33 % vs. 100 %, and 13 % vs. 58 %, respectively; P < 0.0001). Technical success was 100 % in both groups. Procedure time was < 30 minutes in all patients drained with EC-LAMS and over 30 minutes in all patients drained with BFCSEMS (P = 0.0001). Clinical success was higher with a tendency to significance in patients drained with EC-LAMS (96 % vs. 82 %, P = 0.055) and the adverse event rate was lower (4 % vs. 18 %, P = 0.04). No case of procedure-related mortality was recorded. Conclusions EC-LAMS and BFCSEMS are both effective for EUS-guided drainage of PFC. However, EC-LAMS requires less time to be performed and appears to be safer.
ISSN:2364-3722
2196-9736