A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions
Abstract A new bio-mechanical model for elbow flexions is proposed to quantify the elbow torque generated as a function of the upper-arm circumferential strain and influencing factors of elbow angle and angular velocity. The upper-arm circumferential strain is used to represent the contractile inten...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Nature Publishing Group
2017-08-01
|
Series: | Scientific Reports |
Online Access: | https://doi.org/10.1038/s41598-017-09071-x |
id |
doaj-ed634b43ab3e49708289c09002264e78 |
---|---|
record_format |
Article |
spelling |
doaj-ed634b43ab3e49708289c09002264e782020-12-08T00:23:38ZengNature Publishing GroupScientific Reports2045-23222017-08-017111010.1038/s41598-017-09071-xA Bio-mechanical Model for Elbow Isokinetic and Isotonic FlexionsXi Wang0Xiaoming Tao1Raymond C. H. So2Institute of Textiles and Clothing, The Hong Kong Polytechnic UniversityInstitute of Textiles and Clothing, The Hong Kong Polytechnic UniversityHong Kong Sports InstituteAbstract A new bio-mechanical model for elbow flexions is proposed to quantify the elbow torque generated as a function of the upper-arm circumferential strain and influencing factors of elbow angle and angular velocity. The upper-arm circumferential strain is used to represent the contractile intensity of the dominant flexor, biceps brachii, whose behavior is described by Hill’s theory. Experiments with thirteen healthy subjects were conducted to determine the influencing factors. The temporal distributions of torque and elbow angle were measured by Biodex ®3 simultaneously, while the upper-arm circumference was obtained by a wearable anthropometric measurement device. Within the experimental range, the change of angular velocity has been found to have no effect on the torque generated. The new model was further verified experimentally with reasonable agreements obtained. The mean relative error of the torque estimated from the model is 15% and 22%, for isokinetic and isotonic flexions, respectively. The verified model establishes the relationship between the torque generated and circumference strain of the upper arm, for the first time, thus provide a scientific foundation for the anthropometric measurement technology as an alternative to sEMG for monitoring force/torque generation during elbow flexions.https://doi.org/10.1038/s41598-017-09071-x |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Xi Wang Xiaoming Tao Raymond C. H. So |
spellingShingle |
Xi Wang Xiaoming Tao Raymond C. H. So A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions Scientific Reports |
author_facet |
Xi Wang Xiaoming Tao Raymond C. H. So |
author_sort |
Xi Wang |
title |
A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions |
title_short |
A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions |
title_full |
A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions |
title_fullStr |
A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions |
title_full_unstemmed |
A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions |
title_sort |
bio-mechanical model for elbow isokinetic and isotonic flexions |
publisher |
Nature Publishing Group |
series |
Scientific Reports |
issn |
2045-2322 |
publishDate |
2017-08-01 |
description |
Abstract A new bio-mechanical model for elbow flexions is proposed to quantify the elbow torque generated as a function of the upper-arm circumferential strain and influencing factors of elbow angle and angular velocity. The upper-arm circumferential strain is used to represent the contractile intensity of the dominant flexor, biceps brachii, whose behavior is described by Hill’s theory. Experiments with thirteen healthy subjects were conducted to determine the influencing factors. The temporal distributions of torque and elbow angle were measured by Biodex ®3 simultaneously, while the upper-arm circumference was obtained by a wearable anthropometric measurement device. Within the experimental range, the change of angular velocity has been found to have no effect on the torque generated. The new model was further verified experimentally with reasonable agreements obtained. The mean relative error of the torque estimated from the model is 15% and 22%, for isokinetic and isotonic flexions, respectively. The verified model establishes the relationship between the torque generated and circumference strain of the upper arm, for the first time, thus provide a scientific foundation for the anthropometric measurement technology as an alternative to sEMG for monitoring force/torque generation during elbow flexions. |
url |
https://doi.org/10.1038/s41598-017-09071-x |
work_keys_str_mv |
AT xiwang abiomechanicalmodelforelbowisokineticandisotonicflexions AT xiaomingtao abiomechanicalmodelforelbowisokineticandisotonicflexions AT raymondchso abiomechanicalmodelforelbowisokineticandisotonicflexions AT xiwang biomechanicalmodelforelbowisokineticandisotonicflexions AT xiaomingtao biomechanicalmodelforelbowisokineticandisotonicflexions AT raymondchso biomechanicalmodelforelbowisokineticandisotonicflexions |
_version_ |
1724396403324616704 |