A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions

Abstract A new bio-mechanical model for elbow flexions is proposed to quantify the elbow torque generated as a function of the upper-arm circumferential strain and influencing factors of elbow angle and angular velocity. The upper-arm circumferential strain is used to represent the contractile inten...

Full description

Bibliographic Details
Main Authors: Xi Wang, Xiaoming Tao, Raymond C. H. So
Format: Article
Language:English
Published: Nature Publishing Group 2017-08-01
Series:Scientific Reports
Online Access:https://doi.org/10.1038/s41598-017-09071-x
id doaj-ed634b43ab3e49708289c09002264e78
record_format Article
spelling doaj-ed634b43ab3e49708289c09002264e782020-12-08T00:23:38ZengNature Publishing GroupScientific Reports2045-23222017-08-017111010.1038/s41598-017-09071-xA Bio-mechanical Model for Elbow Isokinetic and Isotonic FlexionsXi Wang0Xiaoming Tao1Raymond C. H. So2Institute of Textiles and Clothing, The Hong Kong Polytechnic UniversityInstitute of Textiles and Clothing, The Hong Kong Polytechnic UniversityHong Kong Sports InstituteAbstract A new bio-mechanical model for elbow flexions is proposed to quantify the elbow torque generated as a function of the upper-arm circumferential strain and influencing factors of elbow angle and angular velocity. The upper-arm circumferential strain is used to represent the contractile intensity of the dominant flexor, biceps brachii, whose behavior is described by Hill’s theory. Experiments with thirteen healthy subjects were conducted to determine the influencing factors. The temporal distributions of torque and elbow angle were measured by Biodex ®3 simultaneously, while the upper-arm circumference was obtained by a wearable anthropometric measurement device. Within the experimental range, the change of angular velocity has been found to have no effect on the torque generated. The new model was further verified experimentally with reasonable agreements obtained. The mean relative error of the torque estimated from the model is 15% and 22%, for isokinetic and isotonic flexions, respectively. The verified model establishes the relationship between the torque generated and circumference strain of the upper arm, for the first time, thus provide a scientific foundation for the anthropometric measurement technology as an alternative to sEMG for monitoring force/torque generation during elbow flexions.https://doi.org/10.1038/s41598-017-09071-x
collection DOAJ
language English
format Article
sources DOAJ
author Xi Wang
Xiaoming Tao
Raymond C. H. So
spellingShingle Xi Wang
Xiaoming Tao
Raymond C. H. So
A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions
Scientific Reports
author_facet Xi Wang
Xiaoming Tao
Raymond C. H. So
author_sort Xi Wang
title A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions
title_short A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions
title_full A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions
title_fullStr A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions
title_full_unstemmed A Bio-mechanical Model for Elbow Isokinetic and Isotonic Flexions
title_sort bio-mechanical model for elbow isokinetic and isotonic flexions
publisher Nature Publishing Group
series Scientific Reports
issn 2045-2322
publishDate 2017-08-01
description Abstract A new bio-mechanical model for elbow flexions is proposed to quantify the elbow torque generated as a function of the upper-arm circumferential strain and influencing factors of elbow angle and angular velocity. The upper-arm circumferential strain is used to represent the contractile intensity of the dominant flexor, biceps brachii, whose behavior is described by Hill’s theory. Experiments with thirteen healthy subjects were conducted to determine the influencing factors. The temporal distributions of torque and elbow angle were measured by Biodex ®3 simultaneously, while the upper-arm circumference was obtained by a wearable anthropometric measurement device. Within the experimental range, the change of angular velocity has been found to have no effect on the torque generated. The new model was further verified experimentally with reasonable agreements obtained. The mean relative error of the torque estimated from the model is 15% and 22%, for isokinetic and isotonic flexions, respectively. The verified model establishes the relationship between the torque generated and circumference strain of the upper arm, for the first time, thus provide a scientific foundation for the anthropometric measurement technology as an alternative to sEMG for monitoring force/torque generation during elbow flexions.
url https://doi.org/10.1038/s41598-017-09071-x
work_keys_str_mv AT xiwang abiomechanicalmodelforelbowisokineticandisotonicflexions
AT xiaomingtao abiomechanicalmodelforelbowisokineticandisotonicflexions
AT raymondchso abiomechanicalmodelforelbowisokineticandisotonicflexions
AT xiwang biomechanicalmodelforelbowisokineticandisotonicflexions
AT xiaomingtao biomechanicalmodelforelbowisokineticandisotonicflexions
AT raymondchso biomechanicalmodelforelbowisokineticandisotonicflexions
_version_ 1724396403324616704