Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault

This paper presents the impact of GTO Controlled Series Capacitor (GCSC) parameters on the Inverse Definite Minimum Time (IDMT) Directional Overcurrent Relay (DOCR) based on the International Electrotechnical Commission (IEC) standards. The DOCR is used to protect a single 400 kV transmi...

Full description

Bibliographic Details
Main Authors: Zellagui Mohamed, Benabid Rabah, Chaghi Abdelaziz, Boudour Mohamed
Format: Article
Language:English
Published: Faculty of Technical Sciences in Cacak 2013-01-01
Series:Serbian Journal of Electrical Engineering
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/1451-4869/2013/1451-48691300011Z.pdf
id doaj-ed483ae275cc49edb2fb94eca917afd6
record_format Article
spelling doaj-ed483ae275cc49edb2fb94eca917afd62020-11-24T23:53:32ZengFaculty of Technical Sciences in CacakSerbian Journal of Electrical Engineering1451-48692217-71832013-01-0110338139810.2298/SJEE130505011Z1451-48691300011ZImpact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth faultZellagui Mohamed0Benabid Rabah1Chaghi Abdelaziz2Boudour Mohamed3LSP-IE Laboratory, Department of Electrical Engineering, University of Batna, Campus CUB, Street Med El Hadi Bouklouf, Banta, AlgeriaDepartment of Electrical Engineering, Nuclear Research Center of Birine (CRNB), Djelfa, AlgeriaLSP-IE Laboratory, Department of Electrical Engineering, University of Batna, Campus CUB, Street Med El Hadi Bouklouf, Banta, AlgeriaLSEI Laboratory, Department of Electrical Engineering, University of Sciences and Technology Houari Boumediene (USTHB), El Alia, Bab Ezzouar, Algiers, AlgeriaThis paper presents the impact of GTO Controlled Series Capacitor (GCSC) parameters on the Inverse Definite Minimum Time (IDMT) Directional Overcurrent Relay (DOCR) based on the International Electrotechnical Commission (IEC) standards. The DOCR is used to protect a single 400 kV transmission line of the Algerian transmission network which belongs to the Algerian Company of Electrical and Gas (Group Sonelgaz). The effects of GCSC on transmission line protected parameters as well as fault current and DOCR operation time in the presence of phase to earth fault with fault resistance are investigated considering three scenarios.http://www.doiserbia.nb.rs/img/doi/1451-4869/2013/1451-48691300011Z.pdfGTO Controlled Series Capacitor (GCSC)Apparent reactancephase to earth faultDirectional Overcurrent Relay (DOCR)Inverse Definite Minimum Time (IDMT)operation time
collection DOAJ
language English
format Article
sources DOAJ
author Zellagui Mohamed
Benabid Rabah
Chaghi Abdelaziz
Boudour Mohamed
spellingShingle Zellagui Mohamed
Benabid Rabah
Chaghi Abdelaziz
Boudour Mohamed
Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault
Serbian Journal of Electrical Engineering
GTO Controlled Series Capacitor (GCSC)
Apparent reactance
phase to earth fault
Directional Overcurrent Relay (DOCR)
Inverse Definite Minimum Time (IDMT)
operation time
author_facet Zellagui Mohamed
Benabid Rabah
Chaghi Abdelaziz
Boudour Mohamed
author_sort Zellagui Mohamed
title Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault
title_short Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault
title_full Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault
title_fullStr Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault
title_full_unstemmed Impact of GCSC on IDMT directional overcurrent relay in the presence of phase to earth fault
title_sort impact of gcsc on idmt directional overcurrent relay in the presence of phase to earth fault
publisher Faculty of Technical Sciences in Cacak
series Serbian Journal of Electrical Engineering
issn 1451-4869
2217-7183
publishDate 2013-01-01
description This paper presents the impact of GTO Controlled Series Capacitor (GCSC) parameters on the Inverse Definite Minimum Time (IDMT) Directional Overcurrent Relay (DOCR) based on the International Electrotechnical Commission (IEC) standards. The DOCR is used to protect a single 400 kV transmission line of the Algerian transmission network which belongs to the Algerian Company of Electrical and Gas (Group Sonelgaz). The effects of GCSC on transmission line protected parameters as well as fault current and DOCR operation time in the presence of phase to earth fault with fault resistance are investigated considering three scenarios.
topic GTO Controlled Series Capacitor (GCSC)
Apparent reactance
phase to earth fault
Directional Overcurrent Relay (DOCR)
Inverse Definite Minimum Time (IDMT)
operation time
url http://www.doiserbia.nb.rs/img/doi/1451-4869/2013/1451-48691300011Z.pdf
work_keys_str_mv AT zellaguimohamed impactofgcsconidmtdirectionalovercurrentrelayinthepresenceofphasetoearthfault
AT benabidrabah impactofgcsconidmtdirectionalovercurrentrelayinthepresenceofphasetoearthfault
AT chaghiabdelaziz impactofgcsconidmtdirectionalovercurrentrelayinthepresenceofphasetoearthfault
AT boudourmohamed impactofgcsconidmtdirectionalovercurrentrelayinthepresenceofphasetoearthfault
_version_ 1725469183044485120