Exploring the contribution of efflux on the resistance to fluoroquinolones in clinical isolates of <it>Staphylococcus aureus</it>

<p>Abstract</p> <p>Background</p> <p>Antimicrobial resistance mediated by efflux systems is still poorly characterized in <it>Staphylococcus aureus</it>, despite the description of several efflux pumps (EPs) for this bacterium. In this work we used several m...

Full description

Bibliographic Details
Main Authors: Costa Sofia, Falcão Celeste, Viveiros Miguel, Machado Diana, Martins Marta, Melo-Cristino José, Amaral Leonard, Couto Isabel
Format: Article
Language:English
Published: BMC 2011-10-01
Series:BMC Microbiology
Online Access:http://www.biomedcentral.com/1471-2180/11/241
Description
Summary:<p>Abstract</p> <p>Background</p> <p>Antimicrobial resistance mediated by efflux systems is still poorly characterized in <it>Staphylococcus aureus</it>, despite the description of several efflux pumps (EPs) for this bacterium. In this work we used several methodologies to characterize the efflux activity of 52 <it>S. aureus </it>isolates resistant to ciprofloxacin collected in a hospital in Lisbon, Portugal, in order to understand the role played by these systems in the resistance to fluoroquinolones.</p> <p>Results</p> <p>Augmented efflux activity was detected in 12 out of 52 isolates and correlated with increased resistance to fluoroquinolones. Addition of efflux inhibitors did not result in the full reversion of the fluoroquinolone resistance phenotype, yet it implied a significant decrease in the resistance levels, regardless of the type(s) of mutation(s) found in the quinolone-resistance determining region of <it>grlA </it>and <it>gyrA </it>genes, which accounted for the remaining resistance that was not efflux-mediated. Expression analysis of the genes coding for the main efflux pumps revealed increased expression only in the presence of inducing agents. Moreover, it showed that not only different substrates can trigger expression of different EP genes, but also that the same substrate can promote a variable response, according to its concentration. We also found isolates belonging to the same clonal type that showed different responses towards drug exposure, thus evidencing that highly related clinical isolates may diverge in the efflux-mediated response to noxious agents. The data gathered by real-time fluorometric and RT-qPCR assays suggest that <it>S. aureus </it>clinical isolates may be primed to efflux antimicrobial compounds.</p> <p>Conclusions</p> <p>The results obtained in this work do not exclude the importance of mutations in resistance to fluoroquinolones in <it>S. aureus</it>, yet they underline the contribution of efflux systems for the emergence of high-level resistance. All together, the results presented in this study show the potential role played by efflux systems in the development of resistance to fluoroquinolones in clinical isolates of <it>S. aureus</it>.</p>
ISSN:1471-2180