Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation Study

Purpose: In soft tissues, tumors have generally different sound speeds than normal tissues, so that sound speed images could be used to characterize breast cancer and to study the tumor invasion process. Ultrasound Computed Tomography (UCT) has a great potential to provide quantitative estimations...

Full description

Bibliographic Details
Main Authors: Razieh Solgi, Masoumeh Gity, Hojjat Mahani, Hossein Ghadiri
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2018-06-01
Series:Frontiers in Biomedical Technologies
Subjects:
Online Access:https://fbt.tums.ac.ir/index.php/fbt/article/view/158
id doaj-ec9ee33b3f5c468594e5b7175752c2e1
record_format Article
spelling doaj-ec9ee33b3f5c468594e5b7175752c2e12020-11-25T04:08:32ZengTehran University of Medical SciencesFrontiers in Biomedical Technologies2345-58372018-06-0151-2Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation StudyRazieh Solgi0Masoumeh Gity1Hojjat Mahani2Hossein Ghadiri3Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran. AND Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, IranAdvanced Diagnostic and Interventional Radiology Research Center, Tehran University of Medical Sciences, Tehran, Iran. AND Department of Radiology, Medical Imaging Center, Tehran University of Medical Sciences, Tehran, IranSchool of Radiation Application Research , Nuclear Science and Technology Research Institute, Tehran, IranDepartment of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran. AND Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran Purpose: In soft tissues, tumors have generally different sound speeds than normal tissues, so that sound speed images could be used to characterize breast cancer and to study the tumor invasion process. Ultrasound Computed Tomography (UCT) has a great potential to provide quantitative estimations of physical properties of normal and abnormal tissues that provides accurate characterization capability for breast cancer. The goal of this study is a comparison of two different detector arrangement and image reconstruction filters on image quality parameters in fan-beam back projection method to introduce the modified arrangement and filter to achieve high-quality USCT images. Materials and Methods: Two USCT systems with two different detector arrangement of the ultrasound array, ring-shape and parallel shape, have been simulated and Point Spread Function (PSF), Modulate Transform Function (MTF) and spatial resolution are three image quality parameters, have been investigated in both systems. In this study, a modified filter introduced that apply on the sinogram in two dimensions in spite of the Ram-Lak that apply on sinogram in one dimension. Results: These study results show that the spatial resolution affected by not only detector arrangement but also reconstruction filters. In addition, applying the modified filter improves the resolution of the ring-shaped system and destroy the resolution of the line one and we have higher resolution in the modified filter than Ram-Lak. Conclusion: The result suggests that to have high-resolution USCT images, the difference filters specially modified filter can be used and ring-shaped system has higher resolution images than line one. https://fbt.tums.ac.ir/index.php/fbt/article/view/158Fan Beam Back ProjectionImage QualityReconstruction FiltersUltrasound Computed Tomography
collection DOAJ
language English
format Article
sources DOAJ
author Razieh Solgi
Masoumeh Gity
Hojjat Mahani
Hossein Ghadiri
spellingShingle Razieh Solgi
Masoumeh Gity
Hojjat Mahani
Hossein Ghadiri
Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation Study
Frontiers in Biomedical Technologies
Fan Beam Back Projection
Image Quality
Reconstruction Filters
Ultrasound Computed Tomography
author_facet Razieh Solgi
Masoumeh Gity
Hojjat Mahani
Hossein Ghadiri
author_sort Razieh Solgi
title Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation Study
title_short Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation Study
title_full Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation Study
title_fullStr Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation Study
title_full_unstemmed Effect of Reconstruction Filters on Ultrasound Computed Tomography Image Quality in Two Different Detector Arrangements: A Preliminary Simulation Study
title_sort effect of reconstruction filters on ultrasound computed tomography image quality in two different detector arrangements: a preliminary simulation study
publisher Tehran University of Medical Sciences
series Frontiers in Biomedical Technologies
issn 2345-5837
publishDate 2018-06-01
description Purpose: In soft tissues, tumors have generally different sound speeds than normal tissues, so that sound speed images could be used to characterize breast cancer and to study the tumor invasion process. Ultrasound Computed Tomography (UCT) has a great potential to provide quantitative estimations of physical properties of normal and abnormal tissues that provides accurate characterization capability for breast cancer. The goal of this study is a comparison of two different detector arrangement and image reconstruction filters on image quality parameters in fan-beam back projection method to introduce the modified arrangement and filter to achieve high-quality USCT images. Materials and Methods: Two USCT systems with two different detector arrangement of the ultrasound array, ring-shape and parallel shape, have been simulated and Point Spread Function (PSF), Modulate Transform Function (MTF) and spatial resolution are three image quality parameters, have been investigated in both systems. In this study, a modified filter introduced that apply on the sinogram in two dimensions in spite of the Ram-Lak that apply on sinogram in one dimension. Results: These study results show that the spatial resolution affected by not only detector arrangement but also reconstruction filters. In addition, applying the modified filter improves the resolution of the ring-shaped system and destroy the resolution of the line one and we have higher resolution in the modified filter than Ram-Lak. Conclusion: The result suggests that to have high-resolution USCT images, the difference filters specially modified filter can be used and ring-shaped system has higher resolution images than line one.
topic Fan Beam Back Projection
Image Quality
Reconstruction Filters
Ultrasound Computed Tomography
url https://fbt.tums.ac.ir/index.php/fbt/article/view/158
work_keys_str_mv AT raziehsolgi effectofreconstructionfiltersonultrasoundcomputedtomographyimagequalityintwodifferentdetectorarrangementsapreliminarysimulationstudy
AT masoumehgity effectofreconstructionfiltersonultrasoundcomputedtomographyimagequalityintwodifferentdetectorarrangementsapreliminarysimulationstudy
AT hojjatmahani effectofreconstructionfiltersonultrasoundcomputedtomographyimagequalityintwodifferentdetectorarrangementsapreliminarysimulationstudy
AT hosseinghadiri effectofreconstructionfiltersonultrasoundcomputedtomographyimagequalityintwodifferentdetectorarrangementsapreliminarysimulationstudy
_version_ 1724425261416448000