Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects

The aim of this study was to evaluate the test–retest reliability of a conventional gait model (CGM), the Plug-in Gait model, to calculate the angles of the hip, knee, and ankle during initial contact (IC) and toe-off (TO). Gait analysis was performed using the Vicon Motion System<sup>®</su...

Full description

Bibliographic Details
Main Authors: Francisco Molina-Rueda, Pilar Fernández-González, Alicia Cuesta-Gómez, Aikaterini Koutsou, María Carratalá-Tejada, Juan Carlos Miangolarra-Page
Format: Article
Language:English
Published: MDPI AG 2021-02-01
Series:International Journal of Environmental Research and Public Health
Subjects:
Online Access:https://www.mdpi.com/1660-4601/18/3/1343
id doaj-ec5b13d3fcf84d16a88078c132e1e754
record_format Article
spelling doaj-ec5b13d3fcf84d16a88078c132e1e7542021-02-03T00:04:54ZengMDPI AGInternational Journal of Environmental Research and Public Health1661-78271660-46012021-02-01181343134310.3390/ijerph18031343Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy SubjectsFrancisco Molina-Rueda0Pilar Fernández-González1Alicia Cuesta-Gómez2Aikaterini Koutsou3María Carratalá-Tejada4Juan Carlos Miangolarra-Page5Motion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, SpainMotion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, SpainMotion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, SpainDepartment of Information Systems Engineering, University San Pablo CEU, Boadilla del Monte, 28668 Madrid, SpainMotion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, SpainMotion Analysis, Ergonomics, Biomechanics and Motor Control Laboratory (LAMBECOM), Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, SpainThe aim of this study was to evaluate the test–retest reliability of a conventional gait model (CGM), the Plug-in Gait model, to calculate the angles of the hip, knee, and ankle during initial contact (IC) and toe-off (TO). Gait analysis was performed using the Vicon Motion System<sup>®</sup> (Oxford Metrics, Oxford, UK). The study group consisted of 50 healthy subjects. To evaluate the test–retest reliability, the intraclass correlation coefficient (ICC), the standard error of measurement (SEM), the minimal detectable change (MDC), and the Bland–Altman analysis with 95% limits of agreement were calculated. The ICC for the joint angles of the hip, knee, and ankle was higher than 0.80. However, the ankle angle at IC had an ICC lower than 0.80. The SEM was <5° for all parameters. The MDC was large (>5°) for the hip angle at IC. The Bland–Altman analysis indicated that the magnitude of divergence was between ±5° and ±9° at IC and around ±7° at TO. In conclusion, the ICC for the plug-in gait model was good for the hip, knee, and ankle angles during IC and TO. The plots revealed a disagreement between measurements that should be considered in patients’ clinical assessments.https://www.mdpi.com/1660-4601/18/3/1343biomechanicsgait analysismovement assessmentoptical motion capturereliability
collection DOAJ
language English
format Article
sources DOAJ
author Francisco Molina-Rueda
Pilar Fernández-González
Alicia Cuesta-Gómez
Aikaterini Koutsou
María Carratalá-Tejada
Juan Carlos Miangolarra-Page
spellingShingle Francisco Molina-Rueda
Pilar Fernández-González
Alicia Cuesta-Gómez
Aikaterini Koutsou
María Carratalá-Tejada
Juan Carlos Miangolarra-Page
Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects
International Journal of Environmental Research and Public Health
biomechanics
gait analysis
movement assessment
optical motion capture
reliability
author_facet Francisco Molina-Rueda
Pilar Fernández-González
Alicia Cuesta-Gómez
Aikaterini Koutsou
María Carratalá-Tejada
Juan Carlos Miangolarra-Page
author_sort Francisco Molina-Rueda
title Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects
title_short Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects
title_full Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects
title_fullStr Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects
title_full_unstemmed Test–Retest Reliability of a Conventional Gait Model for Registering Joint Angles during Initial Contact and Toe-Off in Healthy Subjects
title_sort test–retest reliability of a conventional gait model for registering joint angles during initial contact and toe-off in healthy subjects
publisher MDPI AG
series International Journal of Environmental Research and Public Health
issn 1661-7827
1660-4601
publishDate 2021-02-01
description The aim of this study was to evaluate the test–retest reliability of a conventional gait model (CGM), the Plug-in Gait model, to calculate the angles of the hip, knee, and ankle during initial contact (IC) and toe-off (TO). Gait analysis was performed using the Vicon Motion System<sup>®</sup> (Oxford Metrics, Oxford, UK). The study group consisted of 50 healthy subjects. To evaluate the test–retest reliability, the intraclass correlation coefficient (ICC), the standard error of measurement (SEM), the minimal detectable change (MDC), and the Bland–Altman analysis with 95% limits of agreement were calculated. The ICC for the joint angles of the hip, knee, and ankle was higher than 0.80. However, the ankle angle at IC had an ICC lower than 0.80. The SEM was <5° for all parameters. The MDC was large (>5°) for the hip angle at IC. The Bland–Altman analysis indicated that the magnitude of divergence was between ±5° and ±9° at IC and around ±7° at TO. In conclusion, the ICC for the plug-in gait model was good for the hip, knee, and ankle angles during IC and TO. The plots revealed a disagreement between measurements that should be considered in patients’ clinical assessments.
topic biomechanics
gait analysis
movement assessment
optical motion capture
reliability
url https://www.mdpi.com/1660-4601/18/3/1343
work_keys_str_mv AT franciscomolinarueda testretestreliabilityofaconventionalgaitmodelforregisteringjointanglesduringinitialcontactandtoeoffinhealthysubjects
AT pilarfernandezgonzalez testretestreliabilityofaconventionalgaitmodelforregisteringjointanglesduringinitialcontactandtoeoffinhealthysubjects
AT aliciacuestagomez testretestreliabilityofaconventionalgaitmodelforregisteringjointanglesduringinitialcontactandtoeoffinhealthysubjects
AT aikaterinikoutsou testretestreliabilityofaconventionalgaitmodelforregisteringjointanglesduringinitialcontactandtoeoffinhealthysubjects
AT mariacarratalatejada testretestreliabilityofaconventionalgaitmodelforregisteringjointanglesduringinitialcontactandtoeoffinhealthysubjects
AT juancarlosmiangolarrapage testretestreliabilityofaconventionalgaitmodelforregisteringjointanglesduringinitialcontactandtoeoffinhealthysubjects
_version_ 1724290346697883648