Digital Image Correlation Systems in the Experimental Investigations: Capabilities and Limitations

The aim of the paper is to present the possibilities and limitations of using the Digital Image Correlation systems. In order to assess the measurement inaccuracies the measuring volume 1250 × 1100 mm was analysed using two cameras with sensor resolution 6 megapixels. It was stated very good accurac...

Full description

Bibliographic Details
Main Authors: Krawczyk Ł., Gołdyn Michał, Urban Tadeusz
Format: Article
Language:English
Published: Sciendo 2019-03-01
Series:Archives of Civil Engineering
Subjects:
Online Access:http://www.degruyter.com/view/j/ace.2019.65.issue-1/ace-2019-0012/ace-2019-0012.xml?format=INT
id doaj-ebd5eaeb6a0a4413879981f7cc0647aa
record_format Article
spelling doaj-ebd5eaeb6a0a4413879981f7cc0647aa2020-11-25T02:00:18ZengSciendoArchives of Civil Engineering1230-29452019-03-0165117118010.2478/ace-2019-0012ace-2019-0012Digital Image Correlation Systems in the Experimental Investigations: Capabilities and LimitationsKrawczyk Ł.0Gołdyn Michał1Urban Tadeusz2PhD., Eng., Lodz University of Technology, Faculty of Civil Engineering, Al. Politechniki 6, 90-924 Lodz, PolandPhD., Eng., Lodz University of Technology, Faculty of Civil Engineering, Al. Politechniki 6, 90-924 Lodz, PolandProf., DSc., PhD., Eng., Lodz University of Technology, Faculty of Civil Engineering, Al. Politechniki 6, 90-924 Lodz, PolandThe aim of the paper is to present the possibilities and limitations of using the Digital Image Correlation systems. In order to assess the measurement inaccuracies the measuring volume 1250 × 1100 mm was analysed using two cameras with sensor resolution 6 megapixels. It was stated very good accuracy of the line segment length change. It causes that observation of crack widths can be considered as precisely. Some practical information concern how determine the compatibility between crack width measured traditionally and by using DIC are given. In the second part of the paper the results of the tests concerning capacity of interface between two concrete casting at the same time were presented. Use of the optical measurement system Aramis enables the analysis of the deformation, determination of failure mode of the tested specimens and limit displacement between edges of the interface.http://www.degruyter.com/view/j/ace.2019.65.issue-1/ace-2019-0012/ace-2019-0012.xml?format=INTDigital Image Correlation Systemconcrete structuresmeasuring systems
collection DOAJ
language English
format Article
sources DOAJ
author Krawczyk Ł.
Gołdyn Michał
Urban Tadeusz
spellingShingle Krawczyk Ł.
Gołdyn Michał
Urban Tadeusz
Digital Image Correlation Systems in the Experimental Investigations: Capabilities and Limitations
Archives of Civil Engineering
Digital Image Correlation System
concrete structures
measuring systems
author_facet Krawczyk Ł.
Gołdyn Michał
Urban Tadeusz
author_sort Krawczyk Ł.
title Digital Image Correlation Systems in the Experimental Investigations: Capabilities and Limitations
title_short Digital Image Correlation Systems in the Experimental Investigations: Capabilities and Limitations
title_full Digital Image Correlation Systems in the Experimental Investigations: Capabilities and Limitations
title_fullStr Digital Image Correlation Systems in the Experimental Investigations: Capabilities and Limitations
title_full_unstemmed Digital Image Correlation Systems in the Experimental Investigations: Capabilities and Limitations
title_sort digital image correlation systems in the experimental investigations: capabilities and limitations
publisher Sciendo
series Archives of Civil Engineering
issn 1230-2945
publishDate 2019-03-01
description The aim of the paper is to present the possibilities and limitations of using the Digital Image Correlation systems. In order to assess the measurement inaccuracies the measuring volume 1250 × 1100 mm was analysed using two cameras with sensor resolution 6 megapixels. It was stated very good accuracy of the line segment length change. It causes that observation of crack widths can be considered as precisely. Some practical information concern how determine the compatibility between crack width measured traditionally and by using DIC are given. In the second part of the paper the results of the tests concerning capacity of interface between two concrete casting at the same time were presented. Use of the optical measurement system Aramis enables the analysis of the deformation, determination of failure mode of the tested specimens and limit displacement between edges of the interface.
topic Digital Image Correlation System
concrete structures
measuring systems
url http://www.degruyter.com/view/j/ace.2019.65.issue-1/ace-2019-0012/ace-2019-0012.xml?format=INT
work_keys_str_mv AT krawczykł digitalimagecorrelationsystemsintheexperimentalinvestigationscapabilitiesandlimitations
AT gołdynmichał digitalimagecorrelationsystemsintheexperimentalinvestigationscapabilitiesandlimitations
AT urbantadeusz digitalimagecorrelationsystemsintheexperimentalinvestigationscapabilitiesandlimitations
_version_ 1724961464823840768